← Back
Two stories - detached, small or mid-size
35-57 158 STREET
QUEENS · BIN 4119310
💬 Discuss this project
1925Year Built
2.5Stories
A1Building Class
R1-2AZoning
1,873 sfGross Floor Area
1Units
2 Open Violations ▸FDNY Report ↗
Two stories - detached, small or mid-size · 6,000 sf lot · 0.31 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingCivilGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction3p · 1 filing · 2 docs
Floor 2Under Construction40p · 1 filing · 20 docs
Floor 1Under Construction44p · 1 filing · 20 docs
CellarUnder Construction39p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
JIA WEI CONSTRUCTION203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/21/2023$1.3M—— → —$671/sf building
11/05/2018$1.3M—Private party → CALVARY WORLD MISSION CHURCH$675/sf building
02/04/2015$830K—Private party → Private party$443/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TL ENGINEERING, PC1009/04/2025
SYNERGIC DESIGN ARCHITECTS106/20/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JIA WEI CONSTRUCTION INCGeneral Contractor1307/08/2026
ACCORD POWER INCGeneral Contractor304/09/2026
XH&RC PLBG AND HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TL ENGINEERING, PC1222809/04/2025
SYNERGIC DESIGN LLC8561106/20/2025
Building Lifecycle
All (68)Filed (11)Permit Issued (10)Violation (2)Inspection (5)Objection (10)Special Inspection (30)
05/14/2026
Permit issued — Construction Fence
Q00904998-S2-FN
05/14/2026
Permit issued — Earth Work
Q00904998-I1-GC-CX
03/04/2026
Permit issued — Solar
Q01239482-I1-SL
11/20/2025
Permit issued — Structural
Q00904998-I1-GC-CX
10/29/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/29/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/29/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
10/27/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
10/20/2025
Special inspection requirement — Permanent certificate
Simon Lee
10/20/2025
Special inspection requirement — Air barrier — testing
Simon Lee
10/20/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Simon Lee
10/20/2025
Special inspection requirement — Mechanical Systems
Simon Lee
10/20/2025
Special inspection requirement — Structural Steel - Details
Simon Lee
10/20/2025
Special inspection requirement — Masonry
Simon Lee
10/20/2025
Special inspection requirement — Heating Systems
Simon Lee
10/20/2025
Special inspection requirement — Structural Steel - Welding
Simon Lee
10/20/2025
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
Simon Lee
10/20/2025
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
Simon Lee
10/20/2025
Special inspection requirement — Chimneys and vents
Simon Lee
10/20/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Simon Lee
10/20/2025
Special inspection requirement — Subgrade Inspections
Simon Lee
10/20/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Simon Lee
10/20/2025
Special inspection requirement — Concrete - Cast-In-Place
Simon Lee
10/20/2025
Special inspection requirement — Footing and Foundation
Simon Lee
10/20/2025
Special inspection requirement — Final
Simon Lee
10/20/2025
Special inspection requirement — Energy Code Compliance Inspections
Simon Lee
10/20/2025
Special inspection requirement — Fire-Resistance Rated Construction
Simon Lee
10/20/2025
Special inspection requirement — Insulation placement and R values
Simon Lee
10/20/2025
Special inspection requirement — Air barrier - visual inspection
Simon Lee
10/20/2025
Special inspection requirement — Interior lighting power
Simon Lee
10/20/2025
Special inspection requirement — Metering
Simon Lee
10/20/2025
Special inspection requirement — Protection of exposed foundation insulation
Simon Lee
10/20/2025
Special inspection requirement — Fenestration areas
Simon Lee
10/20/2025
Special inspection requirement — Fireplaces
Simon Lee
10/20/2025
Special inspection requirement — Duct leakage testing, insulation and design
Simon Lee
10/20/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Simon Lee
10/20/2025
Special inspection requirement — Fenestration air leakage
Simon Lee
10/20/2025
Special inspection requirement — Maintenance information
Simon Lee
09/04/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
EXISTING ONE FAMILY HOUSE EXTENSION WITH EARTHWORK, FOUNDATION, MECHANICAL SYSTEM & STRUCTURE. EA: EXCAVATION, SITE GRADING AND FILL, FO: CONCRETE FOUNDATION FOR EXTENED HOUSE, MS: NEW HVAC SYSTEM INSTALLATION FOR ENTIRE HOUSE, ST: NEW STRUCTURE SYSTEM.
Q00904998-A1
09/04/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
EXISTING ONE FAMILY HOUSE EXTENSION WITH EARTHWORK, FOUNDATION, MECHANICAL SYSTEM & STRUCTURE. EA: EXCAVATION, SITE GRADING AND FILL, FO: CONCRETE FOUNDATION FOR EXTENED HOUSE, MS: NEW HVAC SYSTEM INSTALLATION FOR ENTIRE HOUSE, ST: NEW STRUCTURE SYSTEM.
Q00904998-A2
07/31/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/27/2025
Permit issued — Solar
Q01239482-I1-SL
06/20/2025
Filed — Alteration
Installation of 9.72 kw solar energy system on roof. No change of occupancy, use or egress.
Q01239482-I1
06/10/2025
Violation issued (ECB, open)
Unknown
06/10/2025
Violation issued (ECB, open)
Construction
02/26/2025
Permit issued — Construction Fence
Q00904998-S2-FN
01/09/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
EXISTING ONE FAMILY HOUSE EXTENSION WITH EARTHWORK, FOUNDATION, MECHANICAL SYSTEM & STRUCTURE. EA: EXCAVATION, SITE GRADING AND FILL, FO: CONCRETE FOUNDATION FOR EXTENED HOUSE, MS: NEW HVAC SYSTEM INSTALLATION FOR ENTIRE HOUSE, ST: NEW STRUCTURE SYSTEM.
Q00904998-P9
01/09/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
EXISTING ONE FAMILY HOUSE EXTENSION WITH EARTHWORK, FOUNDATION, MECHANICAL SYSTEM & STRUCTURE. EA: EXCAVATION, SITE GRADING AND FILL, FO: CONCRETE FOUNDATION FOR EXTENED HOUSE, MS: NEW HVAC SYSTEM INSTALLATION FOR ENTIRE HOUSE, ST: NEW STRUCTURE SYSTEM.
Q00904998-P8
12/16/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
EXISTING ONE FAMILY HOUSE EXTENSION WITH EARTHWORK, FOUNDATION, MECHANICAL SYSTEM & STRUCTURE. EA: EXCAVATION, SITE GRADING AND FILL, FO: CONCRETE FOUNDATION FOR EXTENED HOUSE, MS: NEW HVAC SYSTEM INSTALLATION FOR ENTIRE HOUSE, ST: NEW STRUCTURE SYSTEM.
Q00904998-P6
11/15/2024
Permit issued — Plumbing
Q00904998-S1-PL
07/03/2024
Permit issued — Earth Work
Q00904998-I1-GC-CX
07/01/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
EXISTING ONE FAMILY HOUSE EXTENSION WITH EARTHWORK, FOUNDATION, MECHANICAL SYSTEM & STRUCTURE. EA: EXCAVATION, SITE GRADING AND FILL, FO: CONCRETE FOUNDATION FOR EXTENED HOUSE, MS: NEW HVAC SYSTEM INSTALLATION FOR ENTIRE HOUSE, ST: NEW STRUCTURE SYSTEM.
Q00904998-P3
06/10/2024
Permit issued — Mechanical Systems
Q00904998-I1-GC-CX
05/09/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
EXISTING ONE FAMILY HOUSE EXTENSION WITH EARTHWORK, FOUNDATION, MECHANICAL SYSTEM & STRUCTURE. EA: EXCAVATION, SITE GRADING AND FILL, FO: CONCRETE FOUNDATION FOR EXTENED HOUSE, MS: NEW HVAC SYSTEM INSTALLATION FOR ENTIRE HOUSE, ST: NEW STRUCTURE SYSTEM.
Q00904998-P1
01/16/2024
Permit issued — Construction Fence
Q00904998-S2-FN
12/19/2023
Objection resolved — Addressed
09/06/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
EXISTING ONE FAMILY HOUSE EXTENSION WITH EARTHWORK, FOUNDATION, MECHANICAL SYSTEM & STRUCTURE. EA: EXCAVATION, SITE GRADING AND FILL, FO: CONCRETE FOUNDATION FOR EXTENED HOUSE, MS: NEW HVAC SYSTEM INSTALLATION FOR ENTIRE HOUSE, ST: NEW STRUCTURE SYSTEM.
Q00904998-S2
08/25/2023
Objection resolved — Addressed
08/25/2023
Objection resolved — Addressed
08/25/2023
Objection resolved — Addressed
Latest 60 of 68 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedJIA WEI CONSTRUCTION INC05/14/2026
DOB NOWEarth WorkPermit IssuedJIA WEI CONSTRUCTION INC05/14/2026
DOB NOWSolarPermit IssuedACCORD POWER INC03/04/2026
DOB NOWStructuralPermit IssuedJIA WEI CONSTRUCTION INC11/20/2025
DOB NOWSolarPermit IssuedACCORD POWER INC06/27/2025
DOB NOWConstruction FencePermit IssuedJIA WEI CONSTRUCTION INC02/26/2025
DOB NOWPlumbingPermit IssuedXH&RC PLBG AND HTG INC11/15/2024
DOB NOWEarth WorkPermit IssuedJIA WEI CONSTRUCTION INC07/03/2024
DOB NOWMechanical SystemsPermit IssuedJIA WEI CONSTRUCTION INC06/10/2024
DOB NOWConstruction FencePermit IssuedJIA WEI CONSTRUCTION INC01/16/2024
1 project · most recent 09/04/2025
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
09/04/2025Permit IssuedJIA WEI CONSTRUCTION INCHeating and Air Conditioning Systems
Heat / Cool
Lennox 13ACXN-036 3 tons · Condensing Unit ×6
13ACXN-060-230 5 tons · Condensing Unit ×6
13ACXN-48-230 4 tons · Condensing Unit ×6
Lg LSU181HSV5 18,000 BTU · Condensing Unit ×6
1 project · most recent 09/04/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
09/04/2025Permit IssuedXH&RC PLBG AND HTG INCGas, Storm, Water/Sanitary
3 projects · most recent 06/27/2025
General Wiring Lighting
FiledStatusContractorScope
06/27/2025Permit IssuedACCORD POWER ELECTRIC LLC—
12/13/2024Permit IssuedHI-RITE ELECTRIC CORPGeneral Wiring, Lighting
04/11/2024Permit IssuedHI-RITE ELECTRIC CORP1 meters, 1 new_meters
1 project · most recent 09/04/2025
Steel Masonry
FiledStatusContractorScope
09/04/2025Permit IssuedJIA WEI CONSTRUCTION INCSteel, Masonry
1 project · most recent 06/20/2025
FiledStatusContractorScope
06/20/2025Permit IssuedACCORD POWER INC24 panels, 9.72 kw, 1,470.76 roof_area_sqft
1 project · most recent 09/04/2025
Fence
FiledStatusContractorScope
09/04/2025Permit IssuedJIA WEI CONSTRUCTION INCFence
1 project · most recent 09/04/2025
Earthwork
FiledStatusContractorScope
09/04/2025Permit IssuedJIA WEI CONSTRUCTION INCEarthwork
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
10/29/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/29/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/29/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
10/27/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/31/2025Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
10/20/2025Energy Code Compliance InspectionsSimon Leeprogress
10/20/2025Structural Stability – Alterations of existing buildingsSimon Leespecial
10/20/2025Mechanical SystemsSimon Leespecial
10/20/2025Structural Steel - DetailsSimon Leespecial
10/20/2025MasonrySimon Leespecial
10/20/2025Heating SystemsSimon Leespecial
10/20/2025Structural Steel - WeldingSimon Leespecial
10/20/2025Excavations - Sheeting, Shoring, and BracingSimon Leespecial
10/20/2025Subsurface Conditions – Fill Placement & In-Place DensitySimon Leespecial
10/20/2025Chimneys and ventsSimon Leespecial
10/20/2025Fire-Resistant Penetrations and JointsSimon Leespecial
10/20/2025Subgrade InspectionsSimon Leespecial
10/20/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationSimon Leespecial
10/20/2025Concrete - Cast-In-PlaceSimon Leespecial
10/20/2025Footing and FoundationSimon Leeprogress
10/20/2025FinalSimon Leeprogress
10/20/2025Fire-Resistance Rated ConstructionSimon Leeprogress
10/20/2025Insulation placement and R valuesSimon Leeenergy_progress
10/20/2025Air barrier - visual inspectionSimon Leeenergy_progress
10/20/2025Interior lighting powerSimon Leeenergy_progress
10/20/2025MeteringSimon Leeenergy_progress
10/20/2025Protection of exposed foundation insulationSimon Leeenergy_progress
10/20/2025Fenestration areasSimon Leeenergy_progress
10/20/2025FireplacesSimon Leeenergy_progress
10/20/2025Duct leakage testing, insulation and designSimon Leeenergy_progress
Latest 25 of 150.
▾Documents — 176 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
08/21/2026Q00904998-A1Request digital key ↗
08/21/2026Q00904998-P9Request digital key ↗
08/21/2026Q00904998-P8Request digital key ↗
Showing 3 of 11 on file for this type
▸Applications & Permits2
▸BISBPP-5 - Authorization to the Department of Transportation1
10/05/2023440802641Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
09/15/2023440802641Open ↗
▸Zoning, Tax Lot & Property Records6
▸DOB NOWZD1: DOB Zoning Diagram6
08/13/2026Q00904998-P6Open ↗
08/13/2026Q00904998-P8Open ↗
08/13/2026Q00904998-A1Open ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications112
▸DOB NOWProgress Inspector Seal & Signature58
09/01/2026Q00904998-P3Open ↗
09/01/2026Q00904998-P3Open ↗
09/01/2026Q00904998-P3Open ↗
Showing 3 of 58 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature41
09/01/2026Q00904998-P3Open ↗
09/01/2026Q00904998-P3Open ↗
09/01/2026Q00904998-P3Open ↗
Showing 3 of 41 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/21/2026Q00904998-A1Open ↗
08/21/2026Q00904998-P9Open ↗
08/21/2026Q00904998-P8Open ↗
Showing 3 of 11 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
09/15/2023440802641Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
09/15/2023440802641Open ↗
▸Trade Schedules & Equipment6
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)6
08/13/2026Q00904998-P8Open ↗
08/13/2026Q00904998-P3Open ↗
08/13/2026Q00904998-I1Open ↗
Showing 3 of 6 on file for this type
▸Safety & Tenant Protection4
▸BISSTREET TREES SITE PLAN1
10/05/2023440802641Open ↗
▸BISBPP: STREET TREES SITE PLAN1
10/10/2023440802641Open ↗
▸BISSTREET TREE CHECKLIST1
10/05/2023440802641Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00904998-I1Open ↗
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-5: Asbestos Assessment Report10
08/21/2026Q00904998-S1Open ↗
08/21/2026Q00904998-P9Open ↗
08/21/2026Q00904998-P8Open ↗
Showing 3 of 10 on file for this type
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET1
09/15/2023440802641Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
09/15/2023440802641Open ↗
▸Other Documents23
▸DOB NOWSite Survey: Initial6
08/13/2026Q00904998-I1Open ↗
08/13/2026Q00904998-P6Open ↗
08/13/2026Q00904998-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone6
08/13/2026Q00904998-P8Open ↗
08/13/2026Q00904998-A1Open ↗
08/13/2026Q00904998-P3Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProperty Ownership Certification6
08/21/2026Q00904998-A1Open ↗
08/21/2026Q00904998-P8Open ↗
08/21/2026Q00904998-P6Open ↗
Showing 3 of 6 on file for this type
▸BISBPP: GRADE STUDY1
10/16/2023440802641Open ↗
▸BISBPP: TOPOGRAPHIC SURVEY1
10/10/2023440802641Open ↗
▸BISBPP: PHOTOS-SIGNED/SEALED BY APPLICANT1
10/10/2023440802641Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
09/15/2023440802641Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q00904998-I1Open ↗