HPD12/05/2007SECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 100 WATTS MINIMUM REQUIRED
ECB01/14/2000SPRINKLER HEAD OMITTED AT THIRD AND FOURTH FLOORS IN VIOLATION OF 27-127 OF THE BUILDING CODE. REINSTALL AND CONTACT THE DEPARTMENT FOR INSPECTION.Nothing owed — awaiting certificate of correction
ECB01/14/2000BULKHEAD OF FIRE RESISTANT CONSTRUCTION MEETING THE REQUIREMENTS OF SUB CHAPTER FIVE OF THE BUILDING CODE IS NOT PROVIDED AS PER 27-375 (K)(1). FILE PLANS TO LEGALIZE IF FEASIBLE.Nothing owed — awaiting certificate of correction
ECB01/14/2000SKYLIGHT AND VENTILATORS FOR STAIR ENCLOSURE ARE NOT PROVIDED AS PER SECTION 27-375 (I)(4) OF THE BUILDING CODE. FILE PLANS TO LEGALIZE IF FEASIBLE.Nothing owed — awaiting certificate of correction
ECB01/14/2000ROOF ACCESS IS MISSING IN THAT BUILDINGS MORE THAN THREE STORIES OR FOURTY FEET HIGH SHALL HAVE AN ACCESS TO THE ROOF SECTION 27-375 (K) OF THE BUILDING CODE. FILE PLANS TO LEGALIZE IF FEASIBLE.Nothing owed — awaiting certificate of correction
ECB01/14/2000STAIR ENCLOSURE DOES NOT COMPLY WITH THE REQUIRED FIRE RESISTANCE RATING IN THATA THE BUILDING IS BUILT AS A FOUR STORY OCCUPANCY GROUP J-2, WHICH REQUIRES A TWO HOUR FIRE RATED ENCLOSURE AS PER SECTION 27-375Nothing owed — awaiting certificate of correction
ECB01/14/2000HANDICAP ACCESS TO THE BUILDING IS NOT PROVIDED AS PER SECTION 27-292.5 (A) OF THE BUILDING CODE. FILE PLANS TO LEGALIZE IF FEASIBLE.Nothing owed — awaiting certificate of correction
ECB01/14/2000STRUCTURAL DEFECTS WHICH VIOLATE REFERENCE STANDARD RS10-5B WERE OBSERVED IN THAT NO STRAP BRACING FOR "C" JOINTS PRESENT. ANCHORAGE BETWEEN JOIST AND BEARING OR NON-BEARING WALL WAS NOT PROVIDED. STIFFENothing owed — awaiting certificate of correction
ECB01/14/2000BUILDING DOES NOT COMPLY WITH QUALITY HOUSING PROGRAM AS PER SECTIONS 28-12 AND 28-22 IF THE ZONING RESOLUTION IN THAT THERE ARE NO DOUBLE GLAZED WINDOWS NOR REQUIRED PLANTINGS. FILE PLANS TO LEGALIZE.Nothing owed — awaiting certificate of correction
ECB01/14/2000PARAPET ON EXTERIOR WALL OF BUILDING IS NOT PROVIDED AT THE ROOF OF THE FOURTH FLOOR AS PER SECTION 27-333 OF THE BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLENothing owed — awaiting certificate of correction
ECB01/14/2000FIRE STOPPING AT PARTY WALLS OF BUIDLING IS NOT PROVIDED , CONTRARY TO REQUIREMENTS OF SECTION 27-332 OF THE BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLENothing owed — awaiting certificate of correction
ECB01/14/2000WOOD STAIR BETWEEN CELLAR FIRST FLOOR IS NOT PERMITTED AS PER SECTION 27-375 (H) REMEDY: MAKE STAIR OF NON-COMBUSTIBLE MATERIAL AS REQUIRED BY CODE AND OBTAIN DOB INSPECTIONNothing owed — awaiting certificate of correction
ECB01/14/2000EXISTING APARTMENT DOORS OPEN DIRECTLY INTO STAIR ENCLOSURE CONTRARY TO SECTION 27-375 (J). FILE PLANS TO LEGALIZE IF FEASIBLE.Nothing owed — awaiting certificate of correction
ECB01/14/2000SECOND MEANS OF EGRESS FOR FOUR STORY BUILDING CONSTRUCTION CLASS IIB IS NOT PROVIDED AS PER SECTION 27-366 OF THE BUILDING CODE. FILE PLANSPROVIDE REQUIRED EGRESS.Nothing owed — awaiting certificate of correction
ECB01/13/2000STAIR ENCLOSURE DOES NOT COMPLY WITH THE REQUIRED FIRE RESISTANCE RATING IN THE BUILDING IS BUILT AS A FOUR- STORY , OCCUPANCY GROUP J-2, WHICH REQUIRES A TWO-HOUR FIRE RATED ENCLOSURE AS PER SECTION 27-375 (I)Nothing owed — awaiting certificate of correction
ECB01/13/2000WOOD STAIR BETWEEN CELLAR AND FIRST FLOOR IS NOT PERMITTED: AS PER SECTION 27-375 (H) REMEDY: MAKE STAIR OF NON- COMBUSTIBLE MATERIAL , AS REQUIRED BY CODE , AND OBTAIN D.O.B INSPECTIONNothing owed — awaiting certificate of correction
ECB01/13/2000SPRINKLER HEAD OMITTED AT THIRD AND FOURTH FLOORS IN VIOLATION OF 27-127 OF THE BUILDING CODE. REMEDY: RE-INSTALL AND CONTCT THE DEPARTMENT FOR INSPECTIONNothing owed — awaiting certificate of correction
ECB01/13/2000HANDICAP ACCESS TO THE BUILDING IS NOT PROVIDED AS PER SECTION 27-292.5(A) OF THE BUILDING CODE. FILE PLANS TO LEGALIZE ID FEASIBLE.Nothing owed — awaiting certificate of correction
ECB01/13/2000PARAPET ON EXTERIOR WALL OF BUILDING IS NOT PROVIDED AT THE ROOF OF THE FOURTH FLOOR , AS PER SECTION 27-333 OF THE BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE, IF FEASIBLENothing owed — awaiting certificate of correction
ECB01/13/2000FIRE STOPPING AT PARTY WALL OF BUILDING IS NOT PROVIDED , CONTRARY TO REQUIREMONTS OF SECTION 27-332 OF THE BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE , IF FEASIBLENothing owed — awaiting certificate of correction
ECB01/13/2000STRUCTURAL DEFECTS WHICH VIOLATE REFERENCE STANDARD RS10-5B WERE OBSERVED IN THAT 1- STRAP BRACING FOR "C" JOISTS PRESENT , 2- ANCHORAGE BETWEEN JOIST AND BEARING OR NON- BEARING WALL WAS NOT PROVIDED 3-STIFFENothing owed — awaiting certificate of correction
ECB01/13/2000BUILDING DOES NOT CCOMPLY WITH QUALITY HOUSING PROGRAM AS PER SECTIONS 28-12 AND 28-22 OF THE ZONING RESOLUTION IN THAT THERE ARE NO DOUBBLEGLAZED WINDOWS NOR REQUIRED PLANTINGS. FILE PLANS TO LEGALIZE.Nothing owed — awaiting certificate of correction
ECB01/13/2000SKYLIGHT AND VENTILATORS FOR ENCLOSURE ARE NOT PROVIDED AS PER SECTION27-375 (I) (4) C OF THE BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE , IF FEASIBLENothing owed — awaiting certificate of correction
ECB01/13/2000BULKHEAD OF FIRE RESISTANT CONSTRUCTION MEETING THE REQUIREMENTS OF SUBCHAPTER FIVE OF THE BUILDING CODE IS NOT PROVIDED , AS PER 27-375 (K) (I) REMEDY: FILE PLANS TO LEGALIZE , IF FEASIBLENothing owed — awaiting certificate of correction
ECB01/13/2000SECOND MEANS OF EGRESS FOR FOUR-STORY BUILDING , CONSTRUCTION CLASS 2B, IS NOT PROVIDED AS PER SECTION 27-366 OF THE BUILDING CODE: REMEDY:FILE PLANS TO LEGALZE , IF FEASIBLENothing owed — awaiting certificate of correction
ECB01/13/2000EXISTING APARTMENT DOORS OPEN DIRECTLY INTO STAIR ENCLOSURE, CONTRARY TO SECTION 27-375 (J) REMEDY:FILE PLANS TO LEGALIZE , IF FEASIBLENothing owed — awaiting certificate of correction
ECB01/13/2000ROOF ACCESS IS MISSING IN THAT BUILDING MORE THAN THREE STORIES OR FORTY FEET HIGH SHALL HAVE AN ACCESS TO THE ROOF BY AT LEAST ONE INTERIOR STAIR AS PER SECTION 27-375 (K) OF THE BUILDING CODE. REMEDY: FILE PNothing owed — awaiting certificate of correction
ECB01/06/2000APARTMENTS AT CELLAR WERE CREATED WITHOUT PROPER FILING AND WITHOUT PERMIT AS PER 27-147. REMEDY: OBTAIN PERMIT IF FEASIBLE/FILE PLANS TO LEGALIZE.Nothing owed — awaiting certificate of correction
ECB01/06/2000CELLAR WAS CONVERTED INTO APARTMENTS CONTRARY TO CERTIFICATE OF OCCU- PANCY. REMEDY: DISCONTINUE ILLEGAL USE AND FILE PLANS TO LEGALIZE IF FEASIBLE.Nothing owed — awaiting certificate of correction