ECB08/15/2025NO PERMITS OBTAINED OR CERTIFICATE OF CORRECTION FILED FOR VIOLATION #39026206Y., COMPLY WITH COMMISSIONER'S ORDER$12K due
DOB03/22/2021FTM BLDG SAFE COND:AT EXP1 ENTRE BLDG LEAN SLOPE LINTLS/SILLS,SETTLING PIERS BTWN WINDWS,CRK'D BRKS&MORTAR JOINTS.@EXP2 STL MEMBERS INSTAL NO APPL OR PRMTS.@EXP3 CRK'D BRKS/MORTR JNTS.@INTER FLRS&STAIR PUBLC HALL SAGGED &SLOPED.OWNR RETN PE&DOB REG CONTR EVAL ENTR BLDG&RPR UNDR PRMT CORECT&LEGAL UNPRMIT WRK.FILE BY 5/1/21.BEGN BY 5/15/21.CMPL BY 1/1/22
DOB07/31/2020WORK WITHOUT A PERMIT. OBSERVED STRUCTURAL SHORING INSTALLED AT EXPOSURE #2 BETWEEN BUILDING #35 AND #33 MADISON STREET NO PERMIT NOTED. MINIMUM OF 10 'C' CHANNELS INSTALLED BETWEEN BOTH BUILDINGS. OWNER TO RETAIN P.E AND PROVIDE STRUCTURAL STABILITY REPORT IMMEDIATELY TO DOB.
DOB07/31/2020FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED EGRESS STAIRS THROUGHOUT BUILDING BOTH FRONT AND REAR IN STATE OF DISREPAIR AND HEAVILY OUT OF PLUMB. STAIRS LEANING TOWARD EXPOSURE #2, ALSO NOTED AREAS WHERE STAIR TREAD IS INADEQUATELY SECURED.
DOB07/31/2020FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. OBSERVED AT EXPOSURE #1 CRACKS IN FACADE AT 1S FL ELEVATION, 3 FLOOR KEYSTONE ABOVE WINDOW CRACKED, STONE LINTEL 2ND FL OUT OF PLUMB AND BRICK BETWEEN 2ND AND 3RD FLOOR WINDOWS IN STATE OF DISREPAIR. RESPONDENT TO RETAIN P.E AND PROVIDE FACADE STABILITY REPORT IMMEDIATELY.
HPD04/19/2012§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD04/19/2012§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR SLOPPING FROM WEST TO EAST APPROX 12 FT IN THE 1st ROOM FROM NORTH LOCATED AT APT 1F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD04/19/2012§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 1F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD04/19/2012§ 27-2005 ADM CODE PROVIDE MAIL BOX FOR APT #1F
HPD04/19/2012§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE 1st ROOM FROM NORTH LOCATED AT APT 1F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD04/19/2012§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD03/24/2012§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD03/24/2012§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD02/16/2012§ 27-2047 ADM CODE PROVIDE AND MAINTAIN APPROVED MAIL RECEPTACLES AND DIRECTORIES FOR THE PERSONS RESIDING IN THE DWELLING AS PROVIDED IN THE U.S. POSTAL REGULATIONS. AT PUBLIC HALL, 1st STORY
HPD02/16/2012§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 1F, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD01/27/2012§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD01/27/2012§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD01/06/2012§ 27-2032, 2034 ADM CODE DISCONTINUE USE OF ILLEGAL SPACE AND/OR HOT WATER HEATER AND PROVIDE FILED FOR & APPROVED HEATER WHICH OBTAINS COMBUSTION AIR DIRECTLY FROM OUTSIDE THE BUILDING OR APPROVED CENTRAL SYSTEM ILLEGAL DIRECT VENT GAS WALL HEATER IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 1F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD01/06/2012§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD01/06/2012§ 27-2032, 2034 ADM CODE DISCONTINUE USE OF ILLEGAL SPACE AND/OR HOT WATER HEATER AND PROVIDE FILED FOR & APPROVED HEATER WHICH OBTAINS COMBUSTION AIR DIRECTLY FROM OUTSIDE THE BUILDING OR APPROVED CENTRAL SYSTEM ILLEGAL DIRECT VENT GAS WALL HEATER IN THE 1st ROOM FROM NORTH LOCATED AT APT 1F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD01/06/2012§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD11/28/2011§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRING AT EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD11/28/2011§ 27-2032, 2034 ADM CODE DISCONTINUE USE OF ILLEGAL SPACE AND/OR HOT WATER HEATER AND PROVIDE FILED FOR & APPROVED HEATER WHICH OBTAINS COMBUSTION AIR DIRECTLY FROM OUTSIDE THE BUILDING OR APPROVED CENTRAL SYSTEM ... IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD11/28/2011§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD11/28/2011§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD11/28/2011§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION ERECTED PARTITION WALL & DOOR WITH FULL PLUMBING FIXTURES BATH ROOM IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD11/28/2011§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING KITCHEN HOOD / MECHAICAL VENTILATION SYSTEM AT EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD11/28/2011§ 27-2048 ADM CODE PAINT OR POST A SIGN INDICATING FLOORS AT 1ST & 2ND STY PUBLIC HALLS
HPD11/28/2011§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION SUSPEND CEILING THROUGHOUT IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD11/28/2011§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING FRAME AT PUBLIC HALL, 1st STORY
HPD11/28/2011§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING SIGN AT PUBLIC HALL, 1st STORY
HPD11/28/2011§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY
HPD11/28/2011§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIWIRN AT WEST WALL AT 2ND STY PUBLIC HALL
ECB06/01/2026NOTE: AT TIME OF INSPECTION, I OBSERVED SIDEWALK IN PLACE AT EXPOSURES# 1, UPON REVIEWING DEPARTMENT RECORDS (BIS/DOBNOW), IT WAS FOUND THAT THE SIDEWALK SHED PERMIT (M00745125) WAS EXPIRED ON 03/04/2025. AN ACHearing held — result not yet published$1K proposed
ECB06/01/2026NOTE: AT TIME OF INSPECTION, I OBSERVED A SUPPORTED PIPE SCAFFOLD IN PLACE, AT EXPOSURES#1 THE DEBRIS NETTING WAS NOT SECURELY ATTACHED TO THE SCAFFOLD AT MULTIPLE LOCATIONS AS REQUIRED BY CODE (3314.8.2). THISHearing held — result not yet published$2K proposed
ECB06/01/2026I OBSERVED A SIDEWALK SHED INSTALLED AT EXPO# 1 WITH MISSING INFORMATION PANEL AS REQUIRED BY CODE (3301.9.2) WHICH INCLUDES THE BUILDING ADDRESS AND NAME OF CONTRACTOR AND THE STATEMENT "FOR MORE INFO WITH THEHearing held — result not yet published$1K proposed
ECB08/15/2025AT TIME OF INSPECTION OBSERVED SIDEWALK SHED AND SUPPORTED PIPE SCAFFOLDING ERECTED AT EXPOSURE #1. HOWEVER, PERMITS FOR SCAFFOLDING/SHED(#M00745125-L1-SH, #M00745125-L1-SF) EXPIRED ON 3/4/2025. NO NEW PERMITSNothing owed — awaiting certificate of correction
ECB04/01/2021FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#39026206Y ISSUED ON 7/31/2020 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01.REMEDY:COMPLY WITH COMMNothing owed — awaiting certificate of correction
ECB02/19/2021FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#39026206Y ISSUED ON 07/31/20 & TO FILE A CERT OF CORRECTION PURSUANT TO 28-201.1 & 1RCNY 102-01. WORK W/O PERMIT. REMEDY: COMPLY W/COMM'S ORDER &/ORNothing owed — awaiting certificate of correction
ECB12/21/2020FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#39026206Y ISSUED ON 07/31/20 & TO FILE A CERT OF CORRECTION PURSUANT TO 28-201.1 & 1RCNY 102-01. WORK W/O PERMIT. REMEDY: COMPLY W/COMM'S ORDER &/ORNothing owed — awaiting certificate of correction
ECB10/26/2020FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#39026206Y ISSUED ON 07/31/20 & TO FILE A CERT OF CORRECTION PURSUANT TO 28-201.1 & 1RCNY 102-01. WORK W/O PERMIT. REMEDY: COMPLY W/COMM'S ORDER &/ORNothing owed — awaiting certificate of correction
ECB07/31/2020WORK WITHOUT A PERMIT. OBSERVED STRUCTURAL SHORING INSTALLED AT EXPOSURE #2 BETWEEN BUILDING #35 AND #33 MADISON STREET NO PERMIT NOTED. MINIMUM OF 10 'C' CHANNELS INSTALLED BETWEEN BOTH BUILDINGS. OWNER TO RETNothing owed — awaiting certificate of correction
ECB03/20/2020PROHIBITED LOCATION; I OBSERVED IN HALLWAY OF STREET LEVEL NEWLY INSTALLED GAS METER BAR, FITTINGS AND SEALANT AND METER IS SET IN A PUBLIC HALLWAY WHICH ONCE THE PIPING IS ALTERED NEEDS TO BE REMOVED AND INSTANothing owed — awaiting certificate of correction
ECB03/20/2020I OBSERVED IN HALLWAY ON STREET LEVEL OF BUILDING NEWLY INSTALLED GAS METER BAR, FITTINGS, AND FRESH SEALANT FOR APT#1R AND NO PERMITS ON FILE FOR WORK PERFORMED, OBTAIN PERMITNothing owed — awaiting certificate of correction
ECB03/20/2020I OBSERVED IN HALLWAY OF STREET LEVEL OF BUILDING FOR APT#1R NEWLY INSTALLED GAS PIPING, FITTINGS, METER BAR AND SEALANT AND NO PERMITS ON FILE; THEREFORE NO PROPER TESTING WAS PERFORMED BY THE DOB, PERFORM TESNothing owed — awaiting certificate of correction
ECB03/20/2020I OBSERVED IN HALLWAY OF STREET LEVEL NEWLY INSTALLED GAS PIPING, METER BAR, FITTINGS AND SEALANT AND NO PERMITS ON FILE THEREFORE; NO PROPER CERTIFICATIONS AND OR AUTHORIZATIONS AS PER DOB AND GAS WAS ON AND ANothing owed — awaiting certificate of correction
ECB03/20/2020PROHIBITED FITTINGS; I OBSERVED IN HALLWAY OF STREET LEVEL NEWLY INSTALLED GAS PIPING, FITTINGS, AND SEALANT AND BUSHINGS USED AS A FITTING INSIDE OF AN ELBOW TO REDUCE PIPE DOWN WHICH IS PROHIBITED AND NOT CODNothing owed — awaiting certificate of correction
ECB03/04/2020GAS METERS ARE IN PUBLIC HALLWAYS THROUGHOUT BUILDING INSIDE UNAPPROVED ENCLOSURES. GAS METERS ARE PROHIBITED AS PER APPENDIX E, REPAIR AND/REPLACENothing owed — awaiting certificate of correction
ECB10/29/1998GAS PIPING INSTALLED W/O A PERMIT. FRONT & REAR BLDGS. VIOLATION: PLUMBING WORK W/O A PERMIT. REMEDY: OBTAIN A PERMIT IF FEASIBLE OR RESTORE TO PRIOR LEGAL CONDITION.Nothing owed — awaiting certificate of correction
ECB10/29/1998GAS PIPING & GAS METER EXPOSED IN PUBLIC HALLWAY. VIOLATION: FAILURE TO MAINTAIN PLUMBING (HAZARDOUS). MEMO 6-3-75 BY THOMAS BURKE-DIRECTOROF OPERATIONS (RETRO ACTIVE). REMEDY: MAINTAIN PLUMBING BY REMOVAL ORNothing owed — awaiting certificate of correction
ECB10/29/1998GAS FOR COOKING BEING SUPPLIED TO APTS FRONT & REAR BLDG. VIOLATION: GAS BEING SUPPLIED TO BLDG W/O INSPECTION & CERTIFICATION BY THIS DEPT. REMEDY: FILE FOR REQUIRED PRMITS & HAVE NECESSARY TEST & INSPECNothing owed — awaiting certificate of correction
ECB08/22/1996WORK WITHOUT PERMIT.NOTED STEEL PLATES ERECTED IN REAR ROOM FORMING A ENCLOSURE APPRX 15'X15'X8' HIHG WALLS CEILING FLOOR.DBA MADISON ST JAMES CHECK CASHING CORP.REMEDY OBTAIN PERMIT & APPROVAL FROM NYC BLDG DENothing owed — awaiting certificate of correction