DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
DOB09/23/2024VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
DOB01/15/2020FTM:AT EXP1 HOLE 3"X4'WHERE BLDG&SIDEWALK MET AND LINTELS OVER WINDOWS CORROD.AT ROOF 3 HOLES TWRDS FRNT & 1 TWRDS REAR&DUE TO PARTIAL COLLAP ROOF FRAME.AT REAR,WALL&JOISTS@3FL ROTTED&PART COLLAP.FULL VACATE OF BLDG TIL CONDN'S BEEN REMEDIED.OWNR HAVE STRCT EVAL NYS LIC PE DEVLOP COMP REPR PLAN BY 3/1/20.REPR UNDR PRMT.BEGIN BY 4/1/20 CMPLBY 8/1/20
DOB11/08/2019VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
DOB09/19/2019FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB06/19/2019FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. AT ROOF LEVEL A 4'X8' SECTION OF ROOF WOOD FRAME HAS COLLAPSED INTO INTERIOR OF VACANT BLDG DUE TO A LACK OF MAINTAINANCE OTHER SECTION OF ROOF IN STATE OF DIS$25K due
DOB07/19/2018FTM 3 STRY SEMI DETACH BLDG HAVE DEFECT.THERE IS 2-3"X4"LONG HOLE BET STREET WALL&SIDEWALK.SEVERAL DEFECTS AT LINTELS ABOVE WINDOWS OF FRONT WALL.THERE IS LONG VERT CRACK BET EXP1&4.REAR WALL HAVE VISIBLE CRACKS ABOVE WINDOWS&EAVES.REMEDY:REQ OWN HIRE PE/RA PREP PLAN&OBT PERM FOR RPR NO LATER 8/30/18.RPR START NO LATER 9/20/18&COMP NO LATER 12/20/18
DOB04/06/2018VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
DOB02/24/2017VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
DOB10/01/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
DOB07/01/2015FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB04/08/2015FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB03/03/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
DOB05/15/2014VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
DOB03/01/2013VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
DOB12/13/2011VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
DOB12/31/2009V-DOB VIOLATION - ACTIVE
DOB01/01/2009V-DOB VIOLATION - ACTIVE
DOB01/03/2008V-DOB VIOLATION - ACTIVE
DOB01/19/2007V-DOB VIOLATION - ACTIVE
DOB01/06/2006V-DOB VIOLATION - ACTIVE
DOB03/26/2002V-DOB VIOLATION - ACTIVE
ECB10/15/2020FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#39018683R ISSUED ON 03/02/20 & TO FILE A CERT OF CORRECTION PURSUANT TO 28-201.1 & 1RCNY 102-01. REMEDY: COMPLY W/COMM'S ORDER &/OR FILE A CERT OF CNothing owed — awaiting certificate of correction
ECB02/28/2017AS PER CLASS 2 (B265) 28-303.7 FAILURE TO FILE A COMPLETE BOILER IN SPECTION REPORT AS PER DOB RECORDS. SUBMIT A CURRENT B09 REPORT.Nothing owed — awaiting certificate of correction
ECB05/28/2015FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DOB VIOLATION #3512764241Y ISSUED ON 04/11/15.FOR FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER.REM:COMPLY WITH TNothing owed — awaiting certificate of correction
ECB04/11/2015FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER. NOTED: PREMISES IS UNOCCUPIED & SEALED W/FRONT DOOR SEAL BROKEN,NOW PREMISES IS OPEN & UNGUARDED & IN UNSAFE CONDITION. REMEDY: COMPLY W/NOTICE OF VIOLATION.Nothing owed — awaiting certificate of correction
ECB02/28/2015FAILURE TO COMPLY W/THE COMM'S ORDER TO FILE C OF C W/THE DOB'S FOR NOTICE OF VIO #3511758PR ISSUED ON 1/9/15 PURSUANT TO 28-204.4 & 1RCNY 102-01. REMEDY: FILE A C OF C.Nothing owed — awaiting certificate of correction
ECB01/09/2015FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.NOTED:PREMISES IS UNOCCUPIED AND SEALED WITH FRONT DOOR SEAL BROKEN,NOW PREMISES IS OPEN AN UNGUARDED AND IN UNSAFE CONDITION.REM:REPAIR AND/OR REPLACENothing owed — awaiting certificate of correction