← Back
Elevator cooperative
35 PROSPECT PARK WEST
BROOKLYN · BIN 3025018
💬 Discuss this project
1929Year Built
18Stories
D4Building Class
R8XZoning
191,654 sfGross Floor Area
71Units
LL97 CoveredRent Stabilized1 Open Violation ▸FISP: SWARMPFDNY Report ↗
Elevator cooperative · Owner of record: ADVANCED MANAGEMENT SERVICES · 16,500 sf lot · 11.62 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction6p · 3 filings · 16 docs
PenthouseUnder Construction45p · 8 filings · 20 docs
Floor 1510p · 4 filings · 20 docs
Floor 1417p · 4 filings · 20 docs
Floor 13
Floor 123p · 2 filings · 20 docs
Floor 117p · 1 filing · 14 docs
Floor 103p · 2 filings · 20 docs
Floor 918p · 3 filings · 20 docs
Floor 816p · 3 filings · 20 docs
Floor 72p · 1 filing · 14 docs
Floor 6Under Construction1 filing · 2 docs
Floor 5
Floor 4
Floor 3
Floor 24p · 2 filings · 9 docs
Floor 1Under Construction6p · 3 filings · 20 docs
Cellar6p · 1 filing · 6 docs
Basement1p · 1 filing · 7 docs
4 jobs · most recent 06/10/2026
Air Conditioning Systems Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
06/10/2026Permit IssuedMR. AIR NYC CORPAir Conditioning Systems
Cooling
Mitsubishi Electric MXZ-SM120TAM 120,000 BTU · Heat Pump Outdoor ×1
PVFY-P54NAMU 54,000 BTU · Vrf Indoor ×1
PVFY-P54NMAU 54,000 BTU · Vrf Indoor ×1
12/21/2025Permit IssuedBLACK SQUARE BUILDERS CORHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Magic-Aire DHB10 1,155 CFM · Fan Coil Indoor ×1
DVB10 1,430 CFM · Fan Coil Indoor ×1
National Comfort NCPS-5304000A-A2 27,200 BTU · Condensing Unit ×2
Ventilation
Greenheck SP-B110 40 CFM · Exhaust Fan ×3
Fantech FG-6XL 400 CFM · Kitchen Exhaust ×1
06/17/2025Permit IssuedMARTINEZ CONSTRUCTION MANAir Conditioning Systems
Cooling
Lg ARUM048GSSO 48,000 BTU · Vrf Outdoor ×1
ZRUM036GSSO 36,000 BTU · Vrf Outdoor ×1
ZRUM048GSSO 48,000 BTU · Vrf Outdoor ×1
ZRUM060GSSO 60,000 BTU · Vrf Outdoor ×1
05/21/2021Permit IssuedLTB MECHANICAL CORPAir Conditioning Systems
Cooling
Mitsubishi Electric PURY-EP144TNU-A 12 tons · Vrf Outdoor ×1
4 jobs · most recent 12/21/2025
Gas Water/Sanitary
FiledStatusContractorScope
12/21/2025Signed-offORBIT PLBG & HTG INCGas, Water/Sanitary
09/25/2025——Gas, Water/Sanitary
06/17/2025Permit IssuedM&G PLUMBING AND HEATINGGas, Water/Sanitary
07/24/2023Permit IssuedTOP DOG PLBG & HTG CORPGas, Water/Sanitary
25 jobs · most recent 07/10/2026
General Wiring HVAC Wiring
FiledStatusContractorScope
07/10/2026Permit IssuedINTELOGIC ELECTRIC, INC.HVAC Wiring
06/24/2026CompleteKINGS ELECTRIC CO., INC.General Wiring
06/21/2026CompleteFRIED ELECTRIC CO.General Wiring
05/26/2026CompleteKINGS ELECTRIC CO., INC.General Wiring
03/18/2026Permit IssuedAURORA ELECL CONTG INC—
02/20/2026CompleteOCNYC ELECL CONTNG INC—
01/30/2026Permit IssuedJAM ELECTRICAL CORP—
01/23/2026CompleteAPOLLO ELECTRIC INC.1 meters, 1 new_meters
10/10/2025Permit IssuedAPOLLO ELECTRIC INC.General Wiring
10/01/2025Permit IssuedAPOLLO ELECTRIC INC.—
06/05/2025Permit IssuedEINSTEIN ELEC'L CORP—
05/03/2024CompleteINDY ELECTRIC CORP.General Wiring
02/18/2024CompleteI.D.K. ELECTRIC CO., INC.General Wiring
04/13/2023CompleteLENS ELECTRIC, INC—
03/23/2023CompleteINFINITY ELECTRIC, INCGeneral Wiring
4 jobs · most recent 09/30/2025
Steel Concrete
FiledStatusContractorScope
09/30/2025Permit IssuedMARTINEZ CONSTRUCTION MAN2 scope_items
06/17/2025Permit IssuedMARTINEZ CONSTRUCTION MANSteel, Concrete
06/10/2025Permit IssuedMARTINEZ CONSTRUCTION MANSteel, Concrete
01/26/2024Permit IssuedELITE STYLE CONTRACTINGSteel
1 job · most recent 03/16/2026
Scaffold
FiledStatusContractorScope
03/16/2026Signed-offINTERSYSTEM CONSTRUCTIONScaffold
1 job · most recent 06/15/2025
Suspended Scaffold (SC)
FiledStatusContractorScope
06/15/2025Permit IssuedNY WONDER CONSTRUCTION COSuspended Scaffold (SC)
Building Lifecycle
All (300)Filed (56)Permit Issued (55)Signed Off (24)Facade (FISP) (3)Violation (5)Inspection (47)Objection (80)Special Inspection (30)
09/23/2026
Permit issued — Sidewalk Shed
B01367259-I1-SH
08/06/2026
Signed off — Alteration
INTERIOR RENOVATION OR APARTMENT 6A. NEW FIXTURES, FINISHES, AND PARTITIONS PER PLANS
B01283547-I1
07/06/2026
Permit issued — Mechanical Systems
B01411701-I1-MS
07/02/2026
Permit issued — Sidewalk Shed
B01367259-I1-SH
06/25/2026
Permit issued — General Construction
B01205751-I1-GC
06/10/2026
Filed — Alteration
INSTALL NEW SPLIT A.C. SYSTEM AT FIRST FLOOR OF EXISTING 18-STORY BUILDING WITH MECHANICAL WORK AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR CERTIFICATE OF OCCUPANCY.
B01411701-I1
06/03/2026
Special inspection requirement — HVAC-R and service water heating equipment
Tianchen Hu
06/03/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Tianchen Hu
06/03/2026
Special inspection requirement — Final
Tianchen Hu
06/03/2026
Special inspection requirement — Energy Code Compliance Inspections
Tianchen Hu
06/03/2026
Special inspection requirement — Tenant Protection Plan Compliance
Tianchen Hu
06/03/2026
Special inspection requirement — Mechanical Systems
Tianchen Hu
06/03/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Tianchen Hu
06/03/2026
Special inspection requirement — Maintenance information
Tianchen Hu
06/03/2026
Special inspection requirement — HVAC-R and service water heating system controls
Tianchen Hu
05/15/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
05/05/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/23/2026
Signed off — Alteration
Installation of Air conditioning system and related ductwork and diffusers to provide cooling for apartment. Installation of air intake and discharge vent for condensing units. Installation of humidifier. Replacement of steam traps on existing radiators.
B01251724-I1
03/23/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/19/2026
Permit issued — Sidewalk Shed
B01367259-I1-SH
03/16/2026
Filed — Alteration
Installation of a temporarily supported scaffold and site-specific engineered enclosure per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
B01367189-I1
03/16/2026
Permit issued — Supported Scaffold
B01367189-I1-SF
03/12/2026
Filed — Alteration
B01367259-I1
03/06/2026
Permit issued — Structural
B01205748-I1-ST
03/06/2026
Permit issued — General Construction
B01290059-I1-GC
03/05/2026
Permit issued — Mechanical Systems
B01205743-I1-MS
03/05/2026
Permit issued — Structural
B01218086-I1-ST
03/04/2026
Permit issued — General Construction
B01205739-I1-GC
03/04/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
02/24/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/26/2026
Permit issued — Structural
B01218086-I1-ST
01/15/2026
Permit issued — Structural
B01205748-I1-ST
01/15/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/14/2026
Signed off — Alteration
BATHROOM RENOVATION IN EXISTING APT. 10B FILED IN CONJUNCTION WITH GENERAL CONSTRUCTION WORK. MAKE ADA COMPLIANT EXISTING BATHROOM.
B01203270-I1
01/14/2026
Signed off — Alteration
BATHROOM RENOVATION IN EXISTING APT. 10B FILED IN CONJUNCTION WITH GENERAL CONSTRUCTION WORK. MAKE ADA COMPLIANT EXISTING BATHROOM.
B01203270-S1
01/14/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/09/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
12/23/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Michael Dunham
12/21/2025
Filed — Alteration
Installation of Air conditioning system and related ductwork and diffusers to provide cooling for apartment. Installation of air intake and discharge vent for condensing units. Installation of humidifier. Replacement of steam traps on existing radiators.
B01251724-P1
12/19/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/19/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
12/19/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
12/19/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/19/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
12/16/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Michael Dunham
12/08/2025
Special inspection requirement — Final
Benjamin Herzog
12/08/2025
Special inspection requirement — Lighting in dwelling units
Benjamin Herzog
12/08/2025
Special inspection requirement — Energy Code Compliance Inspections
Benjamin Herzog
12/08/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Benjamin Herzog
12/04/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/02/2025
Filed — Alteration
BATHROOM RENOVATION IN EXISTING APT. 10B FILED IN CONJUNCTION WITH GENERAL CONSTRUCTION WORK. MAKE ADA COMPLIANT EXISTING BATHROOM.
B01203270-P1
12/02/2025
Special inspection requirement — Lighting in dwelling units
Benjamin Herzog
12/02/2025
Special inspection requirement — Final
Benjamin Herzog
12/02/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Benjamin Herzog
12/02/2025
Special inspection requirement — Energy Code Compliance Inspections
Benjamin Herzog
11/26/2025
Objection resolved — Addressed
11/07/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/06/2025
Permit issued — General Construction
B01290059-I1-GC
11/06/2025
Permit issued — Protection and Mechanical Methods
B01313439-I1-PMM
11/05/2025
Filed — Alteration
INSTALLATION OF TEMPORARY WORKING PLATFORM AS PER PLAN. NO CHANGE IN USE, EGRESS, OR OCCUPANCY. THE WORK PLATFORM INSIDE THE BUILDING IN THE SUNROOM FROM THE 6FLOOR TO THE CEILING.
B01313439-I1
Latest 60 of 300 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
INTERSYSTEM CONSTRUCTION CORP.709/24/2026
ADVANCED MANAGEMENT SERVICES8007/08/2026
MARTINEZ CONSTRUCTION MANAGEMENT LL204/09/2026
PLATINUM SERVICES NY503/22/2026
PETER BURGESS MGMT CORP803/22/2026
REAL RENOVATION OF DESIGN503/22/2026
ROCK GROUP NY CORP303/21/2026
35 PARK WEST7603/21/2026
35 WEST PARK OWNERS803/21/2026
C O ADVANCED MANAGEMENT SERVICES703/21/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
GREEN STUDIO203/21/2026
ARGO REAL ESTATE103/21/2026
WILLIAM VITACCO ASSOCIATES2403/21/2026
J CALLAHAN CONSULTING2203/21/2026
REAL RENOVATIONS DESIGN403/21/2026
Shenker Architects403/21/2026
ACA ASSOCIATES203/21/2026
LMS-ACE SERVICES203/21/2026
JEFFREY SANDS ARCHITECT403/21/2026
AE DESIGN SOLUTION403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MARTINEZ CONSTRUCTION MANGeneral Contractor1807/08/2026
SPRING SCAFFOLDING LLCGeneral Contractor1307/08/2026
HD CARPENTRY CORPGeneral Contractor1007/08/2026
KKNY DESIGN INCGeneral Contractor807/08/2026
ORBIT PLBG & HTG INCPlumbing507/08/2026
INTERSYSTEM CONSTRUCTIONGeneral Contractor409/24/2026
TECNY GROUP INCGeneral Contractor403/21/2026
M&G PLUMBING AND HEATINGPlumbing407/08/2026
PLATINUM SERVICES NY LLCGeneral Contractor303/21/2026
GATACA HVAC CORPGeneral Contractor303/21/2026
DONATO PLUMBING, INCPlumbing307/08/2026
PHILIP NABLEGeneral Contractor303/21/2026
AVJ INTERIORS LLCGeneral Contractor303/21/2026
PROCORE MECHANICAL CORPPlumbing207/08/2026
HOME EVOLUTION CONSTRUCTIGeneral Contractor207/08/2026
GO PRO PLUMBING AND HEATINGPlumbing207/08/2026
KAY WATERPROOFING CORPGeneral Contractor203/21/2026
ALPINE REFRIGERATION COPlumbing203/22/2026
LTB MECHANICAL CORPGeneral Contractor203/21/2026
ELITE STYLE CONTRACTINGGeneral Contractor207/08/2026
BLACK SQUARE BUILDERS CORPGeneral Contractor204/09/2026
NICE PLUMBING CORPPlumbing207/08/2026
PREMIER FLOW PLBG AND HTGPlumbing207/08/2026
TOP DOG PLBG & HTG CORPPlumbing107/08/2026
BRENDAN REILLYElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NEW AIR SOLUTION INC8418106/10/2026
DURODECO ARCHITECTURE AND8584312/21/2025
BEN HERZOG ARCHITECT, PC1544312/02/2025
METRIC CONSULTING AND INS1803509/30/2025
RAUCH ARCHITECTURE D.P.C.7888509/25/2025
MEP INSPECTIONS, INC1102908/05/2025
ATOZ CONSULTING ENGINEERS3303107/23/2025
LPE ENGINEERING PC3102205/19/2025
JONATHAN B. HELD AIA ARCH1288404/29/2025
AK CONSULTING SERVICES, I6198504/29/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedPermit IssuedINTERSYSTEM CONSTRUCTION09/23/2026
DOB NOWMechanical SystemsPermit IssuedMR. AIR NYC CORP07/06/2026
DOB NOWSidewalk ShedPermit IssuedINTERSYSTEM CONSTRUCTION07/02/2026
DOB NOWGeneral ConstructionPermit IssuedMARTINEZ CONSTRUCTION MAN06/25/2026
DOB NOWSidewalk ShedPermit IssuedINTERSYSTEM CONSTRUCTION03/19/2026
DOB NOWSupported ScaffoldSigned-offINTERSYSTEM CONSTRUCTION03/16/2026
DOB NOWStructuralPermit IssuedMARTINEZ CONSTRUCTION MAN03/06/2026
DOB NOWGeneral ConstructionPermit IssuedMARTINEZ CONSTRUCTION MAN03/06/2026
DOB NOWMechanical SystemsPermit IssuedMARTINEZ CONSTRUCTION MAN03/05/2026
DOB NOWStructuralPermit IssuedMARTINEZ CONSTRUCTION MAN03/05/2026
DOB NOWGeneral ConstructionPermit IssuedMARTINEZ CONSTRUCTION MAN03/04/2026
DOB NOWStructuralPermit IssuedMARTINEZ CONSTRUCTION MAN01/26/2026
DOB NOWStructuralPermit IssuedMARTINEZ CONSTRUCTION MAN01/15/2026
DOB NOWGeneral ConstructionPermit IssuedMARTINEZ CONSTRUCTION MAN11/06/2025
DOB NOWProtection and Mechanical MethodsPermit IssuedSPRING SCAFFOLDING LLC11/06/2025
DOB NOWMechanical SystemsPermit IssuedMARTINEZ CONSTRUCTION MAN11/03/2025
DOB NOWGeneral ConstructionSigned-offHD CARPENTRY CORP10/23/2025
DOB NOWPlumbingPermit IssuedM&G PLUMBING AND HEATING10/22/2025
DOB NOWMechanical SystemsPermit IssuedBLACK SQUARE BUILDERS COR08/05/2025
DOB NOWGeneral ConstructionSigned-offBLACK SQUARE BUILDERS COR08/04/2025
DOB NOWPlumbingSigned-offORBIT PLBG & HTG INC08/01/2025
DOB NOWPlumbingSigned-offNICE PLUMBING CORP07/30/2025
DOB NOWGeneral ConstructionSigned-offHOME EVOLUTION CONSTRUCTI07/30/2025
DOB NOWStructuralPermit IssuedCH CO INC07/16/2025
DOB NOWSuspended ScaffoldPermit IssuedNY WONDER CONSTRUCTION CO06/16/2025
DOB NOWGeneral ConstructionPermit IssuedMARTINEZ CONSTRUCTION MAN05/29/2025
DOB NOWGeneral ConstructionSigned-offSHL BUILDERS INC03/14/2024
DOB NOWPlumbingSigned-offNEW YORK PARK PLBG&HTG CO02/23/2024
DOB NOWMechanical SystemsSigned-offGATACA HVAC CORP02/22/2024
DOB NOWStructuralPermit IssuedELITE STYLE CONTRACTING02/02/2024
DOB NOWPlumbingSigned-offGO PRO PLUMBING AND HEATI01/31/2024
DOB NOWPlumbingSigned-offDONATO PLUMBING, INC09/14/2023
DOB NOWGeneral ConstructionSigned-offKKNY DESIGN INC08/11/2023
DOB NOWMechanical SystemsSigned-offKKNY DESIGN INC08/11/2023
DOB NOWPlumbingPermit IssuedTOP DOG PLBG & HTG CORP07/05/2023
DOB NOWGeneral ConstructionPermit IssuedTECNY GROUP INC06/28/2023
DOB NOWGeneral ConstructionSigned-offHD CARPENTRY CORP06/08/2023
DOB NOWMechanical SystemsSigned-offHD CARPENTRY CORP05/08/2023
DOB NOWGeneral ConstructionSigned-offTROJAN INTERIORS INC03/11/2023
DOB NOWMechanical SystemsSigned-offREAL RENOVATION & DESIGN02/21/2023
+ 60 more permits on file
▾Field Inspections (DOB CAP) — 47
DateTypeResultReport
05/15/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
05/05/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/23/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/04/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
02/24/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/15/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/14/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/09/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
12/19/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/19/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
12/19/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
12/19/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/19/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
12/04/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/07/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/16/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/14/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
09/11/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/13/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
06/13/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/04/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/26/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
09/06/2024Pass-Final CND-Occupancy InspectionPassView ↗
08/02/2024Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
07/31/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
Latest 25 of 47.
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
06/03/2026Fire-Resistant Penetrations and JointsTianchen Huspecial
06/03/2026Tenant Protection Plan ComplianceTianchen Huspecial
06/03/2026Mechanical SystemsTianchen Huspecial
06/03/2026HVAC-R and service water piping design and insulationTianchen Huenergy_progress
06/03/2026HVAC-R and service water heating system controlsTianchen Huenergy_progress
06/03/2026HVAC-R and service water heating equipmentTianchen Huenergy_progress
06/03/2026Maintenance informationTianchen Huenergy_progress
06/03/2026Energy Code Compliance InspectionsTianchen Huprogress
06/03/2026FinalTianchen Huprogress
12/23/2025Fire-Resistant Penetrations and JointsMichael Dunhamspecial
12/16/2025Fire-Resistant Penetrations and JointsMichael Dunhamspecial
12/08/2025FinalBenjamin Herzogprogress
12/08/2025Fire-Resistant Penetrations and JointsBenjamin Herzogspecial
12/08/2025Energy Code Compliance InspectionsBenjamin Herzogprogress
12/08/2025Lighting in dwelling unitsBenjamin Herzogenergy_progress
12/02/2025Energy Code Compliance InspectionsBenjamin Herzogprogress
12/02/2025Fire-Resistant Penetrations and JointsBenjamin Herzogspecial
12/02/2025Lighting in dwelling unitsBenjamin Herzogenergy_progress
12/02/2025FinalBenjamin Herzogprogress
09/22/2025Fire-Resistant Penetrations and JointsNicolas Crosettospecial
09/19/2025Tenant Protection Plan ComplianceMatthew Rauchspecial
09/19/2025Fire-Resistant Penetrations and JointsMatthew Rauchspecial
09/19/2025Energy Code Compliance InspectionsMatthew Rauchprogress
09/18/2025Structural Stability – Alterations of existing buildingsSAMI HAJJAR P.Especial
09/18/2025FinalJohn McErleanprogress
Latest 25 of 150.
▾Documents — 1,145 on file (BIS + DOB NOW)
▸Plans & Drawings71
▸DOB NOWPlans/Sketch59
09/03/2026B01367189-I1Request digital key ↗
09/01/2026B00500823-I1Request digital key ↗
09/01/2026B00500823-P1Request digital key ↗
Showing 3 of 59 on file for this type
▸DOB NOWPlans/Sketch - Plumbing7
09/02/2026B00351913-I1Request digital key ↗
09/02/2026B00377045-I1Request digital key ↗
09/02/2026B00367073-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems3
09/02/2026B00377064-I1Request digital key ↗
09/02/2026B00367217-P1Request digital key ↗
09/02/2026B00367217-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Sidewalk Shed1
09/02/2026B00118521-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Supported Scaffold1
09/02/2026B00164474-I1Request digital key ↗
▸Applications & Permits164
▸BISPLAN / WORK APPROVAL APPLICATION81
09/18/2025340667380Open ↗
01/30/2025321423250Open ↗
01/21/2025321423250Open ↗
Showing 3 of 81 on file for this type
▸BISWORK PERMIT APPLICATION80
12/23/2022300406521Open ↗
07/29/2021340731569Open ↗
07/21/2021340731569Open ↗
Showing 3 of 80 on file for this type
▸BISLL114/19 PERMIT RESTRICTION2
06/21/2023340733567Open ↗
11/09/2021340731569Open ↗
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
07/08/2022340738214Open ↗
▸Seals & Professional Certifications389
▸DOB NOWProgress Inspector Seal & Signature130
09/26/2026B01203270-S1Open ↗
09/26/2026B01203270-S1Open ↗
09/02/2026B00558447-P2Open ↗
Showing 3 of 130 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature74
09/26/2026B01203270-S1Open ↗
09/02/2026B00558447-P2Open ↗
09/02/2026B00558447-P2Open ↗
Showing 3 of 74 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION71
12/21/2019340570518Open ↗
12/21/2019340570518Open ↗
12/21/2019340570518Open ↗
Showing 3 of 71 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature70
09/03/2026B01367189-I1Open ↗
09/02/2026B00118521-I1Open ↗
09/02/2026B00164474-I1Open ↗
Showing 3 of 70 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST12
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 12 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT9
06/23/2020340738214Open ↗
Showing 1 of 9 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY6
07/28/2020340733567Open ↗
06/23/2020340738214Open ↗
Showing 2 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM6
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 6 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION5
06/23/2020340738214Open ↗
Showing 1 of 5 on file for this type
▸BISAPPLICANT OWNER SIGNATURE5
07/28/2020340733567Open ↗
06/23/2020340731569Open ↗
Showing 2 of 5 on file for this type
▸BISPC FULL REPORT1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Trade Schedules & Equipment68
▸BISSELF-CERT PLUMBING NOTICE33
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 33 on file for this type
▸BISSCHEDULE B - PLUMBING26
10/26/2022300406521Open ↗
09/29/2020340628743Open ↗
04/27/2019340667380Open ↗
Showing 3 of 26 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISEQUIPMENT USE PERMITS1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Safety & Tenant Protection22
▸BISTENANT PROTECTION PLAN AND NOTES13
07/28/2020340733567Open ↗
06/23/2020340738214Open ↗
05/14/2020321069393Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWTenant Protection Plan6
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 6 on file for this type
▸BISSTREET TREE CHECKLIST3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸Environmental & Asbestos97
▸DOB NOWDEP ACP-5: Asbestos Assessment Report62
09/02/2026B00164474-I1Open ↗
09/01/2026B00500823-P1Open ↗
09/01/2026B00500823-I1Open ↗
Showing 3 of 62 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)17
07/28/2020340733567Open ↗
06/23/2020340738214Open ↗
06/23/2020340731569Open ↗
Showing 3 of 17 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'15
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 15 on file for this type
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Energy Compliance77
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS25
12/21/2019340570518Open ↗
12/21/2019340570518Open ↗
12/21/2019340570518Open ↗
Showing 3 of 25 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY17
09/17/2025340667380Open ↗
06/12/2023340733567Open ↗
08/26/2022340628743Open ↗
Showing 3 of 17 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS12
06/28/2022340738214Open ↗
11/03/2021340731569Open ↗
12/21/2019340570518Open ↗
Showing 3 of 12 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS3
07/28/2020340733567Open ↗
06/23/2020340738214Open ↗
Showing 2 of 3 on file for this type
▸BISENERGY CODE COMPLIANCE INSPECTIONS3
09/08/2025340667380Open ↗
01/24/2025321423250Open ↗
06/12/2023340733567Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)3
09/08/2025340667380Open ↗
01/24/2025321423250Open ↗
06/12/2023340733567Open ↗
▸BISTECHNICAL REPORT: ENERGY3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸DOB NOWEN2: As Built Energy Analysis.3
09/01/2026B00558456-I1Open ↗
Showing 1 of 3 on file for this type
▸BISLIGHTING IN DWELLING UNITS2
09/08/2025340667380Open ↗
06/12/2023340733567Open ↗
▸BISTR8: Energy Code Progress Inspections2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISELECTRICAL ENERGY CONSUMPTION1
09/08/2025340667380Open ↗
▸BISLIGHTING CONTROLS1
09/08/2025340667380Open ↗
▸BISINTERIOR LIGHTING POWER1
09/08/2025340667380Open ↗
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Inspections & Test Reports30
▸BISTECHNICAL REPORT: RESPONSIBILITY27
09/17/2025340667380Open ↗
01/24/2025321423250Open ↗
06/12/2023340733567Open ↗
Showing 3 of 27 on file for this type
▸BIS2008 CODE TR1 REQUIRED1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISSTRUCTURAL STABILITY - ALTERATIONS OF EXISTING BUILDINGS1
01/24/2025321423250Open ↗
▸BISMASONRY1
01/24/2025321423250Open ↗
▸Approvals, Objections & Sign-offs78
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST40
09/18/2025340667380Open ↗
02/03/2025321423250Open ↗
06/23/2023340733567Open ↗
Showing 3 of 40 on file for this type
▸BISADMINISTRATIVE OBJECTIONS25
07/19/2020340731569Open ↗
Showing 1 of 25 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE4
03/08/2021300600295Open ↗
03/02/2021300600295Open ↗
01/22/2021300600295Open ↗
Showing 3 of 4 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸BISFINAL3
09/08/2025340667380Open ↗
01/31/2025321423250Open ↗
06/12/2023340733567Open ↗
▸BISSUPERSEDING LETTER2
04/19/2021340733567Open ↗
04/16/2021340733567Open ↗
▸Cost, Insurance & Ownership65
▸BISCOST AFFIDAVIT61
08/26/2022340628743Open ↗
06/28/2022340738214Open ↗
11/12/2021340731569Open ↗
Showing 3 of 61 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW33
09/08/2025340667380Open ↗
01/30/2025321423250Open ↗
06/12/2023340733567Open ↗
▸BISHIC LICENSE OR AFFIDAVIT1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Filing & Intake Forms72
▸BISADDITIONAL INFORMATION28
01/30/2025321423250Open ↗
06/23/2023340733567Open ↗
09/30/2022300406521Open ↗
Showing 3 of 28 on file for this type
▸BISEFILING COVER SHEET27
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 27 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET10
07/28/2020340733567Open ↗
06/23/2020340738214Open ↗
06/23/2020340731569Open ↗
Showing 3 of 10 on file for this type
▸BISBOROUGH INTAKE FORM7
05/13/2021340733567Open ↗
04/19/2021340733567Open ↗
04/16/2021340733567Open ↗
Showing 3 of 7 on file for this type
▸Other Documents6
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION3
04/18/2019321423250Open ↗
Showing 1 of 3 on file for this type
▸DOB NOWCalculations1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type