← Back
Community center
CUNY SC > MAC_341_William E. Macaulay Honors College
35 WEST 67 STREET · BIN 1028237
💬 Discuss this project
1905Year Built
4Stories
P5Building Class
R8Zoning
22,302 sfGross Floor Area
1Units
Rent Stabilized17 Open Violations ▸
Community center · 5,021 sf lot · 4.44 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction50p · 2 filings · 20 docs
Floor 4Under Construction11p · 2 filings · 20 docs
Floor 3Under Construction11p · 2 filings · 20 docs
Floor 2Under Construction11p · 2 filings · 20 docs
Floor 1Under Construction22p · 2 filings · 20 docs
CellarUnder Construction100p · 3 filings · 20 docs
BasementUnder Construction88p · 1 filing · 20 docs
Sub-BasementUnder Construction3p · 1 filing · 20 docs
3 jobs · most recent 04/07/2026
Ventilation Systems Heating and Air Conditioning Systems Heating Systems Air Conditioning Systems Others
FiledStatusContractorScopeMake / Model / Capacity
04/07/2026Permit IssuedA.B.C.D. CONSTRUCTION CORHeating Systems, Ventilation Systems
Heating
Runtal UFLT-3 530 BTU · Radiant ×1
Ventilation
Greenheck SP-LP0511-1 50 CFM · Exhaust Fan ×2
SQ-70-VG 100 CFM · Exhaust Fan ×1
SQ-90-VG 425 CFM · Exhaust Fan ×1
04/03/2026Permit Issued4A CONSTRUCTION CORPAir Conditioning Systems, Heating and Air Conditioning Systems, Ventilation Systems
Cooling
Trane R410A 96,000 BTU · Condensing Unit ×2
Heat / Cool
Trane R410A 150 CFM · Split System ×12
Ventilation
Renewaire RD2XIN 1,860 CFM · Erv ×2
12/08/2024Permit IssuedCLS PROJECT SOLUTIONS INCHeating and Air Conditioning Systems, Others
Heat / Cool
Mitsubishi Electric PUZ-HA24NHA1 24,000 BTU · Vrf Outdoor ×1
Other
Mitsubishi Electric PKA-A24KA8 700 CFM · Heat Pump Outdoor ×1
1 job · most recent 04/03/2026
Sprinkler System
FiledStatusContractorScope
04/03/2026Permit IssuedAJIT ONE MECH & GEN CONTRSprinkler System
3 jobs · most recent 04/07/2026
Water/Sanitary Storm
FiledStatusContractorScope
04/07/2026Permit IssuedVARSITY PLBG AND HTG INCWater/Sanitary
04/03/2026——Storm, Water/Sanitary
12/08/2024Permit IssuedBEDROCK PLBG. & HTG., INCWater/Sanitary
5 jobs · most recent 06/03/2026
General Wiring
FiledStatusContractorScope
06/03/2026Permit IssuedSPICE ELECTRIC COMPANYGeneral Wiring
03/22/2026Permit IssuedDENALI ELECTRIC CORP—
03/12/2026Permit IssuedCORE ELECTRIC MEP INDS LLGeneral Wiring
09/28/2021CompleteABSOLUTE ELEC'L CONTRG OFGeneral Wiring
06/28/2019Permit IssuedJCF ELECTRIC, INC.General Wiring
1 job · most recent 04/03/2026
Steel Concrete Masonry
FiledStatusContractorScope
04/03/2026Permit Issued4A CONSTRUCTION CORPSteel, Concrete, Masonry
Building Lifecycle
All (135)Filed (17)Permit Issued (10)Violation (49)Inspection (7)Objection (22)Special Inspection (30)
09/10/2026
Permit issued — Mechanical Systems
M01235022-S2-MS
08/13/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/11/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/22/2026
Permit issued — Mechanical Systems
M01244182-I1-MS
06/10/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/01/2026
Permit issued — Sprinklers
M01235022-S4-EW-SP
05/20/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
05/19/2026
Permit issued — Structural
M01235022-S1-ST
05/15/2026
Permit issued — Plumbing
M01244182-S1-PL
05/14/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
05/14/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
05/14/2026
Inspection — Certified Sprinkler - SP - Roughing
Certified
View inspection ↗
05/11/2026
Permit issued — Mechanical Systems
M01235022-S2-MS
05/06/2026
Permit issued — General Construction
M01235022-I1-GC
04/28/2026
Special inspection requirement — Final
GEORGE GHEBRYAL
04/28/2026
Special inspection requirement — Masonry
GEORGE GHEBRYAL
04/28/2026
Special inspection requirement — Concrete - Cast-In-Place
GEORGE GHEBRYAL
04/28/2026
Special inspection requirement — Structural Steel - Details
GEORGE GHEBRYAL
04/28/2026
Special inspection requirement — Structural Steel - High Strength Bolting
GEORGE GHEBRYAL
04/28/2026
Special inspection requirement — Structural Steel - Welding
GEORGE GHEBRYAL
04/28/2026
Special inspection requirement — Post-installed Anchors
GEORGE GHEBRYAL
04/28/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
GEORGE GHEBRYAL
04/16/2026
Special inspection requirement — Sprayed fire-resistant materials
GEORGE GHEBRYAL
04/16/2026
Special inspection requirement — Energy Code Compliance Inspections
GEORGE GHEBRYAL
04/16/2026
Special inspection requirement — Interior lighting power
GEORGE GHEBRYAL
04/16/2026
Special inspection requirement — Lighting controls
GEORGE GHEBRYAL
04/16/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
GEORGE GHEBRYAL
04/16/2026
Special inspection requirement — Mastic and Intumescent Fire-resistant Coatings
GEORGE GHEBRYAL
04/07/2026
Filed — Alteration
HERWITH FILING FOR RENOVATIONS OF EXISTING BATHROOM FIXTURES IN ITS ENTIRETY. PROVIDE NEW DOMESTIC COLD WATER, HOTWATER, SANITARY, AND VENT CONNECTIONS AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY
M01244182-P2
04/07/2026
Filed — Alteration
HERWITH FILING FOR RENOVATIONS OF EXISTING BATHROOM FIXTURES IN ITS ENTIRETY. PROVIDE NEW DOMESTIC COLD WATER, HOTWATER, SANITARY, AND VENT CONNECTIONS AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY
M01244182-P1
04/07/2026
Special inspection requirement — Post-installed Anchors
GEORGE GHEBRYAL
04/07/2026
Special inspection requirement — Post-installed Anchors
GEORGE GHEBRYAL
04/07/2026
Special inspection requirement — Energy Code Compliance Inspections
GEORGE GHEBRYAL
04/07/2026
Special inspection requirement — Energy Code Compliance Inspections
GEORGE GHEBRYAL
04/07/2026
Special inspection requirement — Final
GEORGE GHEBRYAL
04/07/2026
Special inspection requirement — Preliminary
Raymond Wong
04/07/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
GEORGE GHEBRYAL
04/07/2026
Special inspection requirement — Mechanical Systems
GEORGE GHEBRYAL
04/07/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
GEORGE GHEBRYAL
04/03/2026
Filed — Alteration CO
HEREWITH FILING FOR STRUCTURAL MODIFICATIONS AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01235022-P2
04/02/2026
Filed — Alteration CO
HEREWITH FILING FOR STRUCTURAL MODIFICATIONS AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01235022-P5
04/02/2026
Filed — Alteration CO
HEREWITH FILING FOR STRUCTURAL MODIFICATIONS AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01235022-P1
04/02/2026
Filed — Alteration CO
HEREWITH FILING FOR STRUCTURAL MODIFICATIONS AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01235022-P3
04/02/2026
Filed — Alteration CO
HEREWITH FILING FOR STRUCTURAL MODIFICATIONS AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01235022-P4
03/23/2026
Permit issued — Mechanical Systems
M01082777-S1-MS
03/10/2026
Special inspection requirement — Preliminary
03/10/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
GEORGE GHEBRYAL
03/10/2026
Special inspection requirement — Mastic and Intumescent Fire-resistant Coatings
GEORGE GHEBRYAL
03/10/2026
Special inspection requirement — Sprayed fire-resistant materials
GEORGE GHEBRYAL
03/10/2026
Special inspection requirement — Energy Code Compliance Inspections
GEORGE GHEBRYAL
03/10/2026
Special inspection requirement — Interior lighting power
GEORGE GHEBRYAL
03/10/2026
Special inspection requirement — Lighting controls
GEORGE GHEBRYAL
03/05/2026
Permit issued — Plumbing
M01082777-S2-PL
03/04/2026
Permit issued — General Construction
M01082777-I1-GC
01/14/2026
Objection resolved — Addressed
01/12/2026
Objection resolved — Addressed
12/08/2025
Objection raised — Structural
12/08/2025
Objection raised — Structural
11/03/2025
Objection resolved — Addressed
10/06/2025
Objection resolved — Addressed
Latest 60 of 135 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MAKOR103/22/2026
OWNER OF 35 WEST 67 STREE103/22/2026
DORMITORY AUTHORITY STATE NY903/21/2026
COLGATE ENTERPRISE203/21/2026
DASNY1003/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
OUTSOURCE CONSULTANTS, INC.1403/21/2026
CONVERSANO ASSOCIATES, INC.603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
A.B.C.D. CONSTRUCTION CORGeneral Contractor307/23/2026
CLS PROJECT SOLUTIONS INCGeneral Contractor204/09/2026
4A CONSTRUCTION CORPGeneral Contractor209/12/2026
AJIT ONE MECH & GEN CONTRFire Protection107/08/2026
BEDROCK PLBG. & HTG., INCPlumbing107/08/2026
FORD, GUYElectrical103/21/2026
VARSITY PLBG AND HTG INCPlumbing108/26/2026
GUY FORDElectrical103/21/2026
PHILIP MISHENElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TECTONIC ENGINEERING CONS1061604/07/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit Issued4A CONSTRUCTION CORP09/10/2026
DOB NOWMechanical SystemsPermit IssuedA.B.C.D. CONSTRUCTION COR07/22/2026
DOB NOWSprinklersPermit IssuedAJIT ONE MECH & GEN CONTR06/01/2026
DOB NOWStructuralPermit IssuedA.B.C.D. CONSTRUCTION COR05/19/2026
DOB NOWPlumbingPermit IssuedZEFI & CO. LLC05/15/2026
DOB NOWMechanical SystemsPermit Issued4A CONSTRUCTION CORP05/11/2026
DOB NOWGeneral ConstructionPermit IssuedA.B.C.D. CONSTRUCTION COR05/06/2026
DOB NOWMechanical SystemsPermit IssuedCLS PROJECT SOLUTIONS INC03/23/2026
DOB NOWPlumbingPermit IssuedBEDROCK PLBG. & HTG., INC03/05/2026
DOB NOWGeneral ConstructionPermit IssuedCLS PROJECT SOLUTIONS INC03/04/2026
BISOTISSUEDPRO CON GROUP INC08/10/2021
BISOTISSUEDPRO CON GROUP INC08/10/2021
BISMHISSUEDPRO CON GROUP INC08/10/2021
BISBLISSUEDCHARLES A DIMINO INC11/01/2019
BISPLISSUEDCHARLES A DIMINO INC10/01/2019
BISOTISSUEDUNIVERSAL HEATING & AIR C05/28/2019
BISOTISSUEDUNIVERSAL HEATING & AIR C05/28/2019
BISOTISSUEDUNIVERSAL HEATING & AIR C01/04/2019
BISMHISSUEDUNIVERSAL HEATING & AIR C01/02/2019
BISBLISSUEDCHARLES A DIMINO INC04/27/2017
BISPLISSUEDCHARLES A DIMINO INC04/27/2017
BISBLISSUEDCHARLES A DIMINO INC12/06/2016
BISPLISSUEDCHARLES A DIMINO INC12/06/2016
BISOTISSUEDUNIVERSAL HEATING & AIR C07/19/2016
BISMHISSUEDUNIVERSAL HEATING & AIR C06/22/2016
BISOTISSUEDUNIVERSAL HEATING & AIR C06/22/2016
BISEQISSUEDCOLGATE ENTERPRISE CORP11/19/2015
BISOTISSUEDUNIVERSAL HEATING & AIR C06/09/2015
BISOTISSUEDUNIVERSAL HEATING & AIR C06/04/2015
BISOTISSUEDUNIVERSAL HEATING & AIR C06/04/2015
BISEQISSUEDYORK SCAFFOLD EQUIPMENT CORP.04/10/2015
BISEQISSUEDGEM CONSTRUCTION & RESTOR11/26/2014
BISEQISSUEDCOLGATE ENTERPRISE CORP11/21/2014
BISEQISSUEDCOLGATE ENTERPRISE CORP11/21/2014
BISBLISSUEDCHARLES A DIMINO INC09/19/2014
BISPLISSUEDCHARLES A DIMINO INC09/19/2014
BISOTISSUEDUNIVERSAL HEATING & AIR C05/29/2014
BISMHISSUEDUNIVERSAL HEATING & AIR C05/29/2014
BISOTISSUEDUNIVERSAL HEATING & AIR C05/01/2014
BISOTISSUEDUNIVERSAL HEATING & AIR C05/01/2014
+ 20 more permits on file
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
08/13/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/11/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/10/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
05/20/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
05/14/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
05/14/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
05/14/2026Certified Sprinkler - SP - RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 54
DateRequirementInspectorRole
04/28/2026FinalGEORGE GHEBRYALprogress
04/28/2026MasonryGEORGE GHEBRYALspecial
04/28/2026Concrete - Cast-In-PlaceGEORGE GHEBRYALspecial
04/28/2026Structural Steel - DetailsGEORGE GHEBRYALspecial
04/28/2026Structural Steel - High Strength BoltingGEORGE GHEBRYALspecial
04/28/2026Structural Steel - WeldingGEORGE GHEBRYALspecial
04/28/2026Post-installed AnchorsGEORGE GHEBRYALspecial
04/28/2026Structural Stability – Alterations of existing buildingsGEORGE GHEBRYALspecial
04/16/2026Sprayed fire-resistant materialsGEORGE GHEBRYALspecial
04/16/2026Energy Code Compliance InspectionsGEORGE GHEBRYALprogress
04/16/2026Interior lighting powerGEORGE GHEBRYALenergy_progress
04/16/2026Lighting controlsGEORGE GHEBRYALenergy_progress
04/16/2026Fire-Resistant Penetrations and JointsGEORGE GHEBRYALspecial
04/16/2026Mastic and Intumescent Fire-resistant CoatingsGEORGE GHEBRYALspecial
04/07/2026Post-installed AnchorsGEORGE GHEBRYALspecial
04/07/2026Post-installed AnchorsGEORGE GHEBRYALspecial
04/07/2026Energy Code Compliance InspectionsGEORGE GHEBRYALprogress
04/07/2026Energy Code Compliance InspectionsGEORGE GHEBRYALprogress
04/07/2026FinalGEORGE GHEBRYALprogress
04/07/2026PreliminaryRaymond Wongprogress
04/07/2026Fire-Resistant Penetrations and JointsGEORGE GHEBRYALspecial
04/07/2026Mechanical SystemsGEORGE GHEBRYALspecial
04/07/2026Fire-Resistant Penetrations and JointsGEORGE GHEBRYALspecial
03/10/2026Preliminary—progress
03/10/2026Fire-Resistant Penetrations and JointsGEORGE GHEBRYALspecial
Latest 25 of 54.
▾Documents — 512 on file (BIS + DOB NOW)
▸Plans & Drawings17
▸DOB NOWPlans/Sketch17
08/25/2026M01082777-S1Request digital key ↗
08/25/2026M01082777-I1Request digital key ↗
08/25/2026M01082777-S2Request digital key ↗
Showing 3 of 17 on file for this type
▸Applications & Permits116
▸BISPLAN / WORK APPROVAL APPLICATION50
10/07/2022123251097Open ↗
10/07/2022123251097Open ↗
03/17/2022123251097Open ↗
Showing 3 of 50 on file for this type
▸BISWORK PERMIT APPLICATION50
08/10/2021123251097Open ↗
08/10/2021123251097Open ↗
08/10/2021123251097Open ↗
Showing 3 of 50 on file for this type
▸DOB NOWLPC Approval/Permit15
08/13/2026M01082777-S2Open ↗
08/13/2026M01235022-S1Open ↗
08/13/2026M01235022-S2Open ↗
Showing 3 of 15 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
08/22/2025123251097Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISZONING EXHIBIT I: CERTIFICATION1
07/05/2018123276533Open ↗
▸Seals & Professional Certifications118
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION45
09/30/2019121675071Open ↗
09/30/2019121675071Open ↗
09/06/2019123251097Open ↗
Showing 3 of 45 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature23
08/25/2026M01082777-I1Open ↗
08/25/2026M01082777-S1Open ↗
08/25/2026M01082777-S2Open ↗
Showing 3 of 23 on file for this type
▸DOB NOWProgress Inspector Seal & Signature14
09/29/2026M01244182-I1Open ↗
09/29/2026M01244182-I1Open ↗
09/02/2026M01235022-S1Open ↗
Showing 3 of 14 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST10
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature10
09/29/2026M01244182-I1Open ↗
09/02/2026M01235022-S1Open ↗
08/31/2026M01244182-S1Open ↗
Showing 3 of 10 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM8
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 8 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
11/18/2014140282192Open ↗
Showing 1 of 2 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
11/18/2014140282192Open ↗
Showing 1 of 2 on file for this type
▸Trade Schedules & Equipment12
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE5
06/04/2019123763935Open ↗
05/17/2019123763935Open ↗
10/30/2015121904537Open ↗
Showing 3 of 5 on file for this type
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT3
03/16/2017121904537Open ↗
03/16/2017121904537Open ↗
Showing 2 of 3 on file for this type
▸BISFA - FDNY APPROVAL : FD-FAA2
02/24/2025123276533Open ↗
Showing 1 of 2 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMITSupporting Document: Fee Exempt1
01/23/2018121904537Open ↗
▸BISEQUIPMENT USE PERMITS1
01/23/2018121904537Open ↗
▸Safety & Tenant Protection27
▸DOB NOWHPD-3: Single Room Occupancy Multiple Dwelling (SRO MD) Anti-Harassment Checklist17
08/13/2026M01235022-P5Open ↗
08/13/2026M01235022-P2Open ↗
08/13/2026M01235022-P4Open ↗
Showing 3 of 17 on file for this type
▸BISSRO MD ANTI-HARASSMENT CHECKLIST6
11/18/2014140282192Open ↗
Showing 1 of 6 on file for this type
▸DOB NOWStreet Tree Checklist2
08/13/2026M01235022-I1Open ↗
08/13/2026M01235022-P1Open ↗
▸BISHPD: SRO MD CERTIFICATE OF NO HARASSMENT1
05/13/2019123251097Open ↗
▸BISANTI-HARASSMENT CHECKLIST1
06/09/2015122274207Open ↗
▸Environmental & Asbestos36
▸DOB NOWDEP ACP-5: Asbestos Assessment Report17
08/25/2026M01082777-I1Open ↗
08/25/2026M01082777-S1Open ↗
08/25/2026M01082777-S2Open ↗
Showing 3 of 17 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'9
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 9 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)4
07/30/2021123251097Open ↗
04/10/2018123276533Open ↗
05/05/2015122274207Open ↗
Showing 3 of 4 on file for this type
▸BISDEP FORM V5 - ASBESTOS VARIANCE1
09/30/2019121675071Open ↗
▸Energy Compliance22
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY12
08/22/2025123251097Open ↗
08/20/2025123251097Open ↗
07/24/2025123251097Open ↗
Showing 3 of 12 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS6
08/22/2025123251097Open ↗
08/20/2025123251097Open ↗
07/24/2025123251097Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS4
01/26/2018122274207Open ↗
06/29/2015122274207Open ↗
02/24/2015122274207Open ↗
Showing 3 of 4 on file for this type
▸Inspections & Test Reports18
▸BISTECHNICAL REPORT: RESPONSIBILITY12
08/22/2025123251097Open ↗
08/20/2025123251097Open ↗
07/24/2025123251097Open ↗
Showing 3 of 12 on file for this type
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER3
08/22/2025123251097Open ↗
08/20/2025123251097Open ↗
07/24/2025123251097Open ↗
▸BISTECHNICAL REPORT: PILE DRIVING2
07/24/2025123251097Open ↗
01/26/2018121904537Open ↗
▸BISHELICAL PILES FOUNDATION (BB # 2014-020)1
07/23/2025123251097Open ↗
▸Approvals, Objections & Sign-offs57
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter17
08/25/2026M01082777-S1Open ↗
08/25/2026M01082777-I1Open ↗
08/25/2026M01082777-S2Open ↗
Showing 3 of 17 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST15
08/22/2025123251097Open ↗
09/30/2019121675071Open ↗
06/24/2019121949687Open ↗
Showing 3 of 15 on file for this type
▸BISLANDMARKS APPROVAL11
09/30/2019121675071Open ↗
05/17/2019123763935Open ↗
05/13/2019123251097Open ↗
Showing 3 of 11 on file for this type
▸BISADMINISTRATIVE OBJECTIONS9
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 9 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION4
04/25/2018140282147Open ↗
04/25/2018140282192Open ↗
Showing 2 of 4 on file for this type
▸BISLANDMARKS SIGNOFF1
07/24/2025123251097Open ↗
▸Cost, Insurance & Ownership26
▸BISCOST AFFIDAVIT26
08/22/2025123251097Open ↗
08/20/2025123251097Open ↗
07/24/2025123251097Open ↗
Showing 3 of 26 on file for this type
▸Filing & Intake Forms51
▸BISEFILING COVER SHEET22
06/04/2019123763935Open ↗
05/17/2019123763935Open ↗
05/17/2019123763935Open ↗
Showing 3 of 22 on file for this type
▸BISBOROUGH INTAKE FORM13
01/14/2020123276533Open ↗
01/10/2020123276533Open ↗
01/10/2020123276533Open ↗
Showing 3 of 13 on file for this type
▸BISADDITIONAL INFORMATION10
08/22/2025123251097Open ↗
10/14/2022123251097Open ↗
10/14/2022123251097Open ↗
Showing 3 of 10 on file for this type
▸BISHPD-3 - SRO MD ANTI-HARASSEMENT CHECKLIST3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET2
11/18/2014140282192Open ↗
Showing 1 of 2 on file for this type
▸BISSRO INTAKE FORM(SRO1)1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Other Documents11
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION11
05/17/2019123762785Open ↗
05/17/2019123763935Open ↗
04/10/2018123276533Open ↗
Showing 3 of 11 on file for this type