← Back
BuildNYC
Elevator cooperative
35 WEST 90TH STREET
MANHATTAN · BIN 1031605
💬 Discuss this project
1931Year Built
12Stories
D4Building Class
R7-2Zoning
109,451 sfGross Floor Area
100Units
LL97 CoveredRent Stabilized0 Active ViolationsFISP: SWARMPFDNY Report ↗
Elevator cooperative · Owner of record: 35 West 90 Owners · 11,783 sf lot · 9.29 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingEquipmentGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Whole building & multi-floor projectsFacade repair and scaffold installation1 filing
RoofHVAC unit and ductwork installation3p · 2 filings · 18 docs
PenthouseUnit PH8, Unit PHB, Unit PHF2p · 2 filings · 20 docs
Floor 11Unit 11H, Unit 11K2 filings · 20 docs
Floor 10
Floor 9
Floor 8Unit 8F, Unit 8G, Unit 8H +15 filings · 18 docs
Floor 7Unit 7G, Unit 7DF2 filings · 20 docs
Floor 6Unit 6F, Unit 6K, Unit 6CD3 filings · 20 docs
Floor 5
Floor 4
Floor 3Unit 3J1 filing · 13 docs
Floor 2
Floor 1
Site & exteriorFacade repairs3 filings · 11 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
35 West 90th Street Owners5003/22/2026
Gentry Apartments503/22/2026
N Y Delta Construction103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Kimoy Studios Architecture509/30/2026
Cowley Engineering302/27/2026
EG Architecture302/17/2026
EP Engineering201/23/2025
Lauren Rubin Architecture809/03/2024
Robert Elliott Leslie Architecture903/25/2024
McMullen Architecture210/23/2023
Ashraf103/09/2023
Paul Perdek, Prof. Engineering102/24/2023
Studio BD609/28/2022
Gurvinder Singh106/27/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Theresa Voltaggio303/21/2026
Edward F Zevallos Architect1003/21/2026
Dominion Expediting803/21/2026
Nyccode603/21/2026
DVA Advisors203/21/2026
Green Studio203/21/2026
Jonathan B. Held A.I.A603/21/2026
J.A.M. Associates1803/21/2026
AE Design Solution203/21/2026
Jonathan B Held AIA603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Nerton ConstructionGeneral Contractor707/08/2026
Heights ConstructionGeneral Contractor603/21/2026
Top Dog Plumbing & HeatingPlumbing407/08/2026
NY Delta ConstructionGeneral Contractor403/21/2026
Aspen InteriorGeneral Contractor303/21/2026
Delta-Sigma MechanicalPlumbing307/08/2026
Platinum Services NYScaffold303/21/2026
Van Nest ConstructionGeneral Contractor303/21/2026
Sohome WorkGeneral Contractor207/08/2026
Kings Group NYScaffold207/08/2026
Crossfield Plumbing & HeatingPlumbing207/08/2026
Super Charged ElectricElectrical103/21/2026
Twintech ElectricElectrical103/22/2026
Midland Electrical CoElectrical103/21/2026
Shuir Electrical ContractorsElectrical103/22/2026
Expert PaintingScaffold107/08/2026
Orbit Plumbing & HeatingPlumbing107/08/2026
Ariana ContractingPlumbing107/08/2026
Calray Gas HeatPlumbing107/08/2026
CJ Heating & MechanicalPlumbing107/08/2026
High Quality Electric ofElectrical103/22/2026
Qec Electrical SvceElectrical103/22/2026
G.P. MechanicalPlumbing107/08/2026
M InteriorsGeneral Contractor104/09/2026
MNR GroupGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Cowley Engineering186302/27/2026
EP Inspections and Commis7079602/17/2026
O'Rourke Engineering5873112/20/2024
Kimoy Studios3572112/20/2024
Lauren Rubin Architecture1143408/22/2024
Crosscheck Inspection Services544210/23/2023
Jonathan B. Held AIA Architects1288409/28/2022
Building Lifecycle
All (235)Filed (41)Permit Issued (32)Signed Off (20)Facade (FISP) (13)Violation (53)Inspection (20)Objection (26)Special Inspection (30)
10/02/2026
Objection raised — Other
10/02/2026
Objection raised — Other
10/02/2026
Objection raised — Admin
10/02/2026
Objection raised — Other
10/02/2026
Objection raised — Admin
10/02/2026
Objection raised — Other
10/02/2026
Objection raised — Scope
10/02/2026
Objection raised — Other
10/02/2026
Objection raised — Scope
09/30/2026
Filed — Alteration
Architectural and minor mechanical scope associated with apt.7DF and apt. 7G combination in accordance with TPPN #3/97. No change of use, egress, or occupancy.
M01452759-I1
09/30/2026
Filed — Alteration
Architectural and minor mechanical scope associated with apt.7DF and apt. 7G combination in accordance with TPPN #3/97. No change of use, egress, or occupancy.
M01452759-S1
09/22/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
09/22/2026
Special inspection requirement — HVAC-R and service water heating equipment
09/17/2026
Special inspection requirement — Lighting in dwelling units
08/28/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
08/28/2026
Special inspection requirement — Mechanical Systems
08/28/2026
Special inspection requirement — Post-installed Anchors
08/28/2026
Special inspection requirement — Final
04/02/2026
Signed off — Alteration
REMOVE AND INSTALL PLUMBING FIXTURES.
M01021750-I1
04/01/2026
Signed off — Alteration
REMOVE AND INSTALL PLUMBING FIXTURES.
M01021750-S1
04/01/2026
Signed off — Alteration
Installation of HVAC unit and associated ductwork. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
M01091742-I1
03/03/2026
Signed off — Alteration
Slab repair in unit 8F as per plans filed herewith. No change to use, egress, or occupancy.
M01272226-I1
02/27/2026
Filed — Alteration
Slab repair in unit 8F as per plans filed herewith. No change to use, egress, or occupancy.
M01272226-P1
02/17/2026
Filed — Alteration
REMOVE AND INSTALL PLUMBING FIXTURES.
M01021750-P1
12/06/2025
Violation issued (HPD, closed)
C
12/06/2025
Violation issued (HPD, closed)
C
10/30/2025
Permit issued — Structural
M01272226-I1-GC-CX
09/09/2025
Filed — Alteration
Slab repair in unit 8F as per plans filed herewith. No change to use, egress, or occupancy.
M01272226-I1
08/06/2025
Permit issued — Plumbing
M01021750-S1-PL
05/05/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/01/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/01/2025
Violation issued (HPD, closed)
C
02/04/2025
Special inspection requirement — Mechanical Systems
MOLLY GLENN
02/04/2025
Special inspection requirement — Final
MOLLY GLENN
02/04/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
MOLLY GLENN
02/04/2025
Special inspection requirement — Exhaust and Vent Systems in Plenums and Ducts
MOLLY GLENN
02/04/2025
Special inspection requirement — Post-installed Anchors
MOLLY GLENN
01/27/2025
Permit issued — Plumbing
M01106608-S1-PL
01/23/2025
Filed — Alteration
Installation of HVAC unit and associated ductwork. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
M01091742-P1
01/17/2025
Signed off — Alteration
Minor general interior apartment renovation including mechanical work. Minor plumbing work to be filed subsequently. No change to use, egress or occupancy.
M01093680-I1
01/08/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
John Kim
01/08/2025
Special inspection requirement — Final
John Kim
01/08/2025
Special inspection requirement — Post-installed Anchors
BRIAN O'ROURKE
01/07/2025
Special inspection requirement — Mechanical Systems
MOLLY GLENN
01/07/2025
Special inspection requirement — Final
MOLLY GLENN
01/07/2025
Special inspection requirement — Post-installed Anchors
MOLLY GLENN
01/07/2025
Special inspection requirement — Exhaust and Vent Systems in Plenums and Ducts
MOLLY GLENN
01/07/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
MOLLY GLENN
01/06/2025
Filed — Alteration
Architectural scope associated with the apt.7DF interior renovation. No change of use, egress or occupancy.
M01106608-P1
01/02/2025
Objection resolved — Addressed
01/02/2025
Objection resolved — Addressed
01/02/2025
Objection resolved — Addressed
12/24/2024
Objection raised — Structural
12/24/2024
Objection raised — Other
12/24/2024
Objection raised — Other
12/20/2024
Filed — Alteration
Architectural scope associated with the apt.7DF interior renovation. No change of use, egress or occupancy.
M01106608-I1
12/20/2024
Filed — Alteration
Architectural scope associated with the apt.7DF interior renovation. No change of use, egress or occupancy.
M01106608-S1
12/17/2024
Signed off — Alteration
Minor general interior apartment renovation including mechanical work. Minor plumbing work to be filed subsequently. No change to use, egress or occupancy.
M01093680-S1
12/11/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
12/02/2024
Permit issued — Mechanical Systems
M01091742-I1-MS
Latest 60 of 235 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offM Interiors10/30/2025
DOB NOWPlumbingSigned-offDelta-Sigma Mechanical08/06/2025
DOB NOWPlumbingPermit IssuedOrbit Plumbing & Heating01/27/2025
DOB NOWMechanical SystemsSigned-offHeights Construction12/02/2024
DOB NOWPlumbingSigned-offCrossfield Plumbing & Heating09/16/2024
DOB NOWMechanical SystemsSigned-offSohome Work09/10/2024
DOB NOWPlumbingSigned-offDelta-Sigma Mechanical08/29/2024
DOB NOWGeneral ConstructionSigned-offHeights Construction08/29/2024
DOB NOWPlumbingSigned-offCalray Gas Heat06/28/2024
DOB NOWPlumbingSigned-offCJ Heating & Mechanical04/17/2024
DOB NOWGeneral ConstructionSigned-offVan Nest Construction03/18/2024
DOB NOWGeneral ConstructionSigned-offAspen Interior12/01/2023
DOB NOWPlumbingSigned-offG.P. Mechanical11/30/2023
DOB NOWPlumbingSigned-offCrossfield Plumbing & Heating10/11/2023
DOB NOWMechanical SystemsSigned-offSohome Work09/27/2023
DOB NOWSupported ScaffoldPermit IssuedExpert Painting08/01/2023
DOB NOWGeneral ConstructionSigned-offMNR Group05/17/2023
DOB NOWPlumbingSigned-offDelta-Sigma Mechanical05/05/2023
DOB NOWGeneral ConstructionSigned-offNY Delta Construction05/02/2023
DOB NOWSidewalk ShedSigned-offPlatinum Services NY03/10/2023
DOB NOWSupported ScaffoldPermit IssuedExpert Painting02/25/2023
DOB NOWGeneral ConstructionSigned-offNerton Construction04/19/2022
DOB NOWPlumbingSigned-offTop Dog Plumbing & Heating04/07/2022
DOB NOWPlumbingPermit IssuedTop Dog Plumbing & Heating04/07/2022
DOB NOWPlumbingSigned-offAriana Contracting04/04/2022
DOB NOWGeneral ConstructionSigned-offNY Delta Construction03/28/2022
DOB NOWPlumbingSigned-offTop Dog Plumbing & Heating02/21/2022
DOB NOWGeneral ConstructionSigned-offNerton Construction02/18/2022
DOB NOWPlumbingPermit IssuedTop Dog Plumbing & Heating10/05/2021
DOB NOWGeneral ConstructionSigned-offNerton Construction09/23/2021
DOB NOWSidewalk ShedSigned-offKings Group NY09/19/2019
DOB NOWSidewalk ShedSigned-offKings Group NY06/27/2019
BISOTISSUEDRomo Construction06/26/2019
BISPLISSUEDDoval Plumbing & Heating05/08/2017
BISMHISSUEDSohome Work05/03/2017
BISOTISSUEDSohome Work05/02/2017
BISMHISSUEDStanley Ruth Co09/09/2016
BISPLISSUEDAriel Services07/22/2016
BISOTISSUEDCrafted Interiors Design06/14/2016
BISOTISSUEDIndigo Blue Group07/30/2014
+ 42 more permits on file
1 project · most recent 09/30/2026
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
09/30/2026——Air Conditioning Systems
Cooling
Ice Air 8RSAN17 19,500 BTU · Ptac ×1
3 projects · most recent 09/30/2026
Gas Water/Sanitary
FiledStatusContractorScope
09/30/2026——Gas, Water/Sanitary
01/06/2025Permit IssuedOrbit Plumbing & HeatingGas, Water/Sanitary
09/28/2022Permit IssuedTop Dog Plumbing & HeatingGas, Water/Sanitary
16 projects · most recent 08/23/2026
General Wiring
FiledStatusContractorScope
08/23/2026CompleteBNH ElectricalGeneral Wiring
03/04/2026Permit IssuedNew Century Electrical ContractingGeneral Wiring
01/20/2026CompleteVere Electric—
01/29/2025Permit IssuedApollo Electric NYGGeneral Wiring
11/07/2024CompleteBay ElectricGeneral Wiring
11/05/2024CompleteAmor ElectricGeneral Wiring
09/09/2024CompleteAmergy Electric of NY—
06/18/2024CompleteCentrum ElectricGeneral Wiring
10/31/2023CompleteExpress Design & ElectricalGeneral Wiring
04/12/2023Permit IssuedHigh Quality Electric of—
02/28/2023CompleteIlluminous ElectricGeneral Wiring
11/04/2022CompleteQec Electrical SvceGeneral Wiring
05/23/2022CompleteTwintech ElectricGeneral Wiring
04/12/2022CompleteTwintech ElectricGeneral Wiring
08/12/2021CompleteShuir Electrical ContractorsGeneral Wiring
1 project · most recent 02/24/2023
Scaffold
FiledStatusContractorScope
02/24/2023Permit IssuedExpert PaintingScaffold
▾Field Inspections (DOB CAP) — 20
DateTypeResultReport
05/05/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/01/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
12/11/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/31/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/14/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/07/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/25/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/07/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
06/07/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/08/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
12/29/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/08/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/21/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/08/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/15/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/15/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/15/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/15/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/29/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/13/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 72
DateRequirementInspectorRole
09/22/2026Fire-Resistant Penetrations and Joints—special
09/22/2026HVAC-R and service water heating equipment—energy_progress
09/17/2026Lighting in dwelling units—energy_progress
08/28/2026Final—progress
08/28/2026Post-installed Anchors—special
08/28/2026Fire-Resistant Penetrations and Joints—special
08/28/2026Mechanical Systems—special
02/04/2025Mechanical SystemsMOLLY GLENNspecial
02/04/2025Exhaust and Vent Systems in Plenums and DuctsMOLLY GLENNspecial
02/04/2025Fire-Resistant Penetrations and JointsMOLLY GLENNspecial
02/04/2025Post-installed AnchorsMOLLY GLENNspecial
02/04/2025FinalMOLLY GLENNprogress
01/08/2025FinalJohn Kimprogress
01/08/2025Fire-Resistant Penetrations and JointsJohn Kimspecial
01/08/2025Post-installed AnchorsBRIAN O'ROURKEspecial
01/07/2025FinalMOLLY GLENNprogress
01/07/2025Exhaust and Vent Systems in Plenums and DuctsMOLLY GLENNspecial
01/07/2025Post-installed AnchorsMOLLY GLENNspecial
01/07/2025Fire-Resistant Penetrations and JointsMOLLY GLENNspecial
01/07/2025Mechanical SystemsMOLLY GLENNspecial
08/08/2024FinalLAUREN RUBINprogress
08/08/2024Fire-Resistant Penetrations and JointsLAUREN RUBINspecial
08/08/2024Mechanical SystemsLAUREN RUBINspecial
08/08/2024Interior lighting powerLAUREN RUBINenergy_progress
08/08/2024HVAC-R and service water piping design and insulationLAUREN RUBINenergy_progress
Latest 25 of 72.
▾Documents — 465 on file (BIS + DOB NOW)
▸Plans & Drawings41
▸DOB NOWPlans/Sketch40
10/04/2026M01452759-S1Request digital key ↗
10/04/2026M01452759-I1Request digital key ↗
09/03/2026M00545339-I1Request digital key ↗
Showing 3 of 40 on file for this type
▸DOB NOWPlans/Sketch - Sidewalk Shed1
09/05/2026M00185403-I1Request digital key ↗
▸Applications & Permits89
▸DOB NOWLPC Approval/Permit36
08/15/2026M00629470-I1Open ↗
08/14/2026M00628947-I1Open ↗
08/13/2026M01005387-P1Open ↗
Showing 3 of 36 on file for this type
▸BISWORK PERMIT APPLICATION26
06/26/2019123469781Open ↗
05/08/2017140619070Open ↗
05/03/2017140619070Open ↗
Showing 3 of 26 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION26
09/12/2023103919299Open ↗
03/16/2021121765893Open ↗
03/09/2021121765893Open ↗
Showing 3 of 26 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
07/05/2017104221352Open ↗
▸Seals & Professional Certifications128
▸DOB NOWDPL-1: Design Professional Seal & Signature41
10/04/2026M01452759-I1Open ↗
10/04/2026M01452759-S1Open ↗
09/02/2026M00629470-I1Open ↗
Showing 3 of 41 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION36
01/09/2020123469781Open ↗
01/09/2020123469781Open ↗
01/09/2020123469781Open ↗
Showing 3 of 36 on file for this type
▸DOB NOWProgress Inspector Seal & Signature24
09/28/2026M00568996-I1Open ↗
09/01/2026M00901868-I1Open ↗
09/01/2026M00901868-I1Open ↗
Showing 3 of 24 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature15
10/08/2026M00901868-S1Open ↗
09/01/2026M00901868-I1Open ↗
09/01/2026M00550868-P1Open ↗
Showing 3 of 15 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST4
06/26/2019123469781Open ↗
03/11/2014121924784Open ↗
Showing 2 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
06/26/2019123469781Open ↗
04/07/2014140182219Open ↗
03/11/2014121924784Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
04/28/2017140619070Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
04/07/2014140182219Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
04/07/2014140182219Open ↗
▸Trade Schedules & Equipment23
▸BISSELF-CERT PLUMBING NOTICE12
12/10/2014121968692Open ↗
10/17/2014121944192Open ↗
08/16/2014121944192Open ↗
Showing 3 of 12 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE6
09/06/2016122738001Open ↗
09/02/2016122738001Open ↗
05/25/2016122738001Open ↗
Showing 3 of 6 on file for this type
▸BISSCHEDULE B - PLUMBING5
04/05/2017140619070Open ↗
04/15/2014121968692Open ↗
Showing 2 of 5 on file for this type
▸Safety & Tenant Protection3
▸BISTenant Protection Plan and Notes3
06/26/2019123469781Open ↗
05/25/2016122738001Open ↗
04/05/2017140619070Open ↗
▸Environmental & Asbestos47
▸DOB NOWDEP ACP-5: Asbestos Assessment Report32
10/04/2026M01452759-S1Open ↗
10/04/2026M01452759-I1Open ↗
09/02/2026M00550868-I1Open ↗
Showing 3 of 32 on file for this type
▸BISASBESTOS-CERTIFICATION (DEP ACP5)8
04/16/2014121968692Open ↗
04/15/2014121968692Open ↗
06/26/2019123469781Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form4
08/31/2026M00760414-I1Open ↗
08/19/2026M01021750-S1Open ↗
08/19/2026M01021750-I1Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Energy Compliance30
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS13
01/09/2020123469781Open ↗
01/09/2020123469781Open ↗
01/06/2020123469781Open ↗
Showing 3 of 13 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS8
01/09/2020123469781Open ↗
01/06/2020123469781Open ↗
06/28/2018104221352Open ↗
Showing 3 of 8 on file for this type
▸BISTR8: Energy Code Progress Inspections4
01/06/2015121924784Open ↗
05/27/2014121944192Open ↗
04/15/2014121968692Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWEN2: As Built Energy Analysis2
08/14/2026M00628947-I1Open ↗
08/13/2026M00545339-I1Open ↗
▸BISTECHNICAL REPORT: ENERGY1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
04/07/2014140182219Open ↗
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026M01005387-I1Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
02/09/2021121765893Open ↗
04/07/2014140182219Open ↗
▸Approvals, Objections & Sign-offs38
▸BISLANDMARKS APPROVAL15
01/09/2020123469781Open ↗
01/06/2020123469781Open ↗
06/26/2019123469781Open ↗
Showing 3 of 15 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST15
03/25/2021121765893Open ↗
01/09/2020123469781Open ↗
01/06/2020123469781Open ↗
Showing 3 of 15 on file for this type
▸BISADMINISTRATIVE OBJECTIONS5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISLANDMARKS SIGNOFF2
02/09/2021121765893Open ↗
08/30/2018140619070Open ↗
▸BISLETTERS - APPROVED FABRICATION CERTIFICATIONS1
04/23/2013120721683Open ↗
▸Cost, Insurance & Ownership24
▸BISCOST AFFIDAVIT24
02/09/2021121765893Open ↗
01/09/2020123469781Open ↗
01/06/2020123469781Open ↗
Showing 3 of 24 on file for this type
▸Filing & Intake Forms28
▸BISEFILING COVER SHEET10
06/26/2019123469781Open ↗
05/25/2016122738001Open ↗
04/15/2014121968692Open ↗
Showing 3 of 10 on file for this type
▸BISBOROUGH INTAKE FORM8
01/09/2020123469781Open ↗
01/06/2020123469781Open ↗
12/13/2019123469781Open ↗
Showing 3 of 8 on file for this type
▸BISADDITIONAL INFORMATION7
12/18/2019123469781Open ↗
05/23/2018104221352Open ↗
08/21/2017122738001Open ↗
Showing 3 of 7 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET3
04/05/2017140619070Open ↗
04/07/2014140182219Open ↗
Showing 2 of 3 on file for this type
▸Other Documents12
▸DOB NOWProof of Historic Building6
08/13/2026M01021750-I1Open ↗
08/13/2026M00901868-I1Open ↗
08/13/2026M01106608-I1Open ↗
Showing 3 of 6 on file for this type
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION4
06/17/2016122738001Open ↗
Showing 1 of 4 on file for this type
▸BISECCCNYS ANALYSIS1
04/17/2017140619070Open ↗
▸BISDepartment of Consumer Affairs (DCA) Form1
05/27/2014121944192Open ↗