← Back
Four families
350 6 AVENUE
BROOKLYN · BIN 3021219
💬 Discuss this project
1920Year Built
4Stories
C3Building Class
R6BZoning
4,125 sfGross Floor Area
4Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Four families · Owner of record: 350 PS LLC · 1,527 sf lot · 2.7 FAR built · Flood zone X
Locations of Work
ArchitectureLandscape
Roof10p · 1 filing · 20 docs
Floor 49p · 1 filing · 20 docs
Floor 39p · 1 filing · 20 docs
Floor 29p · 1 filing · 20 docs
Floor 19p · 1 filing · 20 docs
Cellar11p · 2 filings · 20 docs
1 job · most recent 05/03/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/03/2026Permit IssuedNYC BUILDING SOLUTIONS COHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MXZ-SM36NAM2-U1 41,000 BTU · Condensing Unit ×3
PEFY-P36NMAU-E4 40,000 BTU · Vrf Indoor ×3
MXZ-SM60NAM2-U1 66,000 BTU · Condensing Unit ×1
PEFY-P54NMAU-E4 60,000 BTU · Vrf Indoor ×1
Ventilation
Panasonic FV-0510VS1 100 CFM · Exhaust Fan ×4
Zline 695RD-40 700 CFM · Kitchen Exhaust ×4
1 job · most recent 05/03/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
05/03/2026Signed-offRRP PLUMBING CORPGas, Storm, Water/Sanitary
1 job · most recent 07/21/2025
General Wiring
FiledStatusContractorScope
07/21/2025CompleteSAFEWAY CONSTRUCTION, INCGeneral Wiring
Building Lifecycle
All (59)Filed (8)Permit Issued (4)Signed Off (2)Violation (6)Inspection (5)Objection (4)Special Inspection (30)
06/05/2026
Special inspection requirement — Fenestration air leakage
William Alicea
06/05/2026
Special inspection requirement — Insulation placement and R values
William Alicea
06/05/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
William Alicea
06/05/2026
Special inspection requirement — Fenestration areas
William Alicea
06/05/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
William Alicea
06/05/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
William Alicea
06/05/2026
Special inspection requirement — Protection of exposed foundation insulation
William Alicea
06/05/2026
Special inspection requirement — Metering
William Alicea
06/05/2026
Special inspection requirement — Air barrier - visual inspection
William Alicea
06/05/2026
Special inspection requirement — Exterior lighting power
William Alicea
06/05/2026
Special inspection requirement — Interior lighting power
William Alicea
06/05/2026
Special inspection requirement — Permanent certificate
William Alicea
06/05/2026
Special inspection requirement — Energy Code Compliance Inspections
William Alicea
06/05/2026
Special inspection requirement — Fire-Resistance Rated Construction
William Alicea
06/05/2026
Special inspection requirement — Lighting in dwelling units
William Alicea
06/05/2026
Special inspection requirement — Maintenance information
William Alicea
06/05/2026
Special inspection requirement — Lighting controls
William Alicea
05/22/2026
Objection resolved — Addressed
05/20/2026
Objection raised — Scope
05/03/2026
Filed — Alteration CO
Interior renovation of an existing 4 family structure, including interior partial non structural demolition, new partitions, new finishes. to obtain new CO
B01094442-P5
04/30/2026
Violation issued (HPD, closed)
A
02/12/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/03/2025
Signed off — Alteration CO
Interior renovation of an existing 4 family structure, including interior partial non structural demolition, new partitions, new finishes. to obtain new CO
B01094442-S1
09/28/2025
Filed — Alteration CO
Interior renovation of an existing 4 family structure, including interior partial non structural demolition, new partitions, new finishes. to obtain new CO
B01094442-P4
09/25/2025
Special inspection requirement — Permanent certificate
William Alicea
09/25/2025
Special inspection requirement — Fenestration air leakage
William Alicea
09/25/2025
Special inspection requirement — Lighting controls
William Alicea
09/25/2025
Special inspection requirement — Fenestration areas
William Alicea
09/25/2025
Special inspection requirement — Maintenance information
William Alicea
09/25/2025
Special inspection requirement — Interior lighting power
William Alicea
09/25/2025
Special inspection requirement — Energy Code Compliance Inspections
William Alicea
09/25/2025
Special inspection requirement — Metering
William Alicea
09/25/2025
Special inspection requirement — Exterior lighting power
William Alicea
09/25/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
William Alicea
09/25/2025
Special inspection requirement — Fire-Resistance Rated Construction
William Alicea
09/25/2025
Special inspection requirement — Air barrier - visual inspection
William Alicea
09/25/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
William Alicea
09/24/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/18/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/01/2025
Permit issued — General Construction
B01094442-I1-GC
06/11/2025
Signed off — Alteration CO
Interior renovation of an existing 4 family structure, including interior partial non structural demolition, new partitions, new finishes. to obtain new CO
B01094442-S2
06/05/2025
Violation issued (HPD, closed)
A
06/02/2025
Objection resolved — Addressed
05/21/2025
Objection raised — Scope
05/12/2025
Filed — Alteration CO
Interior renovation of an existing 4 family structure, including interior partial non structural demolition, new partitions, new finishes. to obtain new CO
B01094442-P3
05/08/2025
Filed — Alteration CO
Interior renovation of an existing 4 family structure, including interior partial non structural demolition, new partitions, new finishes. to obtain new CO
B01094442-P1
04/07/2025
Permit issued — Mechanical Systems
B01094442-S2-MS
03/28/2025
Filed — Alteration CO
Interior renovation of an existing 4 family structure, including interior partial non structural demolition, new partitions, new finishes. to obtain new CO
B01094442-S2
01/28/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/24/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/22/2025
Permit issued — Plumbing
B01094442-S1-PL
12/27/2024
Permit issued — General Construction
B01094442-I1-GC
12/02/2024
Filed — Alteration CO
Interior renovation of an existing 4 family structure, including interior partial non structural demolition, new partitions, new finishes. to obtain new CO
B01094442-S1
11/13/2024
Filed — Alteration CO
Interior renovation of an existing 4 family structure, including interior partial non structural demolition, new partitions, new finishes. to obtain new CO
B01094442-I1
10/23/2024
Filed — Alteration
HEREWITH TO FILE TO RELAMINATE EXISTING WALLS, NEW GYP BOARD, REPLACE WINDOWS AND ALL FINISHES AS PER PLANS. COSMETIC RENOVATION TO EXISTING 4 STORY, 4 FAMILY DWELLLING. NO CHANGE IN USE, OCCUPANCY, BULK, OR EGRESS
B01114096-I1
03/20/2023
Violation issued (HPD, closed)
A
04/05/2021
Violation issued (HPD, closed)
A
10/06/2015
Violation issued (HPD, closed)
I
02/05/2015
Violation issued (HPD, closed)
I
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MINERVA1307/08/2026
350 PS LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/18/2024$3.8M—— → —$909/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JBA305/03/2026
WORLD DESIGN ARCHITECTURE,PLLC305/12/2025
CHUN ENGINEERING CONSULTANT PLLC203/28/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NYC BUILDING SOLUTIONS703/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NYC BUILDING SOLUTIONS COGeneral Contractor307/08/2026
RRP PLUMBING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
WORLD DESIGN ARCHITECTURE9323705/03/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedNYC BUILDING SOLUTIONS CO07/01/2025
DOB NOWMechanical SystemsSigned-offNYC BUILDING SOLUTIONS CO04/07/2025
DOB NOWPlumbingSigned-offRRP PLUMBING CORP01/22/2025
DOB NOWGeneral ConstructionPermit IssuedNYC BUILDING SOLUTIONS CO12/27/2024
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
02/12/2026Pass-Final CND-Occupancy InspectionPassView ↗
09/24/2025Pass-Final CND-Occupancy InspectionPassView ↗
09/18/2025Pass-Final CND-Occupancy InspectionPassView ↗
01/28/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/24/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 66
DateRequirementInspectorRole
06/05/2026MeteringWilliam Aliceaenergy_progress
06/05/2026Insulation placement and R valuesWilliam Aliceaenergy_progress
06/05/2026Lighting controlsWilliam Aliceaenergy_progress
06/05/2026Protection of exposed foundation insulationWilliam Aliceaenergy_progress
06/05/2026Maintenance informationWilliam Aliceaenergy_progress
06/05/2026Interior lighting powerWilliam Aliceaenergy_progress
06/05/2026Air barrier - visual inspectionWilliam Aliceaenergy_progress
06/05/2026Fenestration and door U-factor and product ratingsWilliam Aliceaenergy_progress
06/05/2026Exterior lighting powerWilliam Aliceaenergy_progress
06/05/2026Permanent certificateWilliam Aliceaenergy_progress
06/05/2026Fenestration air leakageWilliam Aliceaenergy_progress
06/05/2026Fenestration areasWilliam Aliceaenergy_progress
06/05/2026Lighting in dwelling unitsWilliam Aliceaenergy_progress
06/05/2026Fire-Resistance Rated ConstructionWilliam Aliceaprogress
06/05/2026Energy Code Compliance InspectionsWilliam Aliceaprogress
06/05/2026Fire-Resistant Penetrations and JointsWilliam Aliceaspecial
06/05/2026Structural Stability – Alterations of existing buildingsWilliam Aliceaspecial
09/25/2025Lighting in dwelling unitsWilliam Aliceaenergy_progress
09/25/2025Structural Stability – Alterations of existing buildingsWilliam Aliceaspecial
09/25/2025Energy Code Compliance InspectionsWilliam Aliceaprogress
09/25/2025Fire-Resistance Rated ConstructionWilliam Aliceaprogress
09/25/2025Exterior lighting powerWilliam Aliceaenergy_progress
09/25/2025Maintenance informationWilliam Aliceaenergy_progress
09/25/2025Fenestration air leakageWilliam Aliceaenergy_progress
09/25/2025Protection of exposed foundation insulationWilliam Aliceaenergy_progress
Latest 25 of 66.
▾Documents — 67 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/23/2026B01114096-I1Request digital key ↗
08/21/2026B01094442-P4Request digital key ↗
08/21/2026B01094442-P1Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits3
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION2
04/16/2025322118702Open ↗
04/16/2025322118702Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
03/17/2025322118702Open ↗
▸Zoning, Tax Lot & Property Records8
▸DOB NOWHouse Number Verification: TOPO Stamp4
08/13/2026B01094442-P1Open ↗
08/13/2026B01094442-P4Open ↗
08/13/2026B01094442-P5Open ↗
Showing 3 of 4 on file for this type
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
04/16/2025322118702Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
04/16/2025322118702Open ↗
▸BISADDRESS: NEW HOUSE NUMBER APPROVED1
04/16/2025322118702Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
04/16/2025322118702Open ↗
▸Seals & Professional Certifications24
▸DOB NOWProgress Inspector Seal & Signature11
08/30/2026B01114096-I1Open ↗
08/27/2026B01094442-P4Open ↗
08/27/2026B01094442-P4Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/21/2026B01094442-P4Open ↗
08/21/2026B01094442-P1Open ↗
08/17/2026B01094442-S1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
08/27/2026B01094442-P4Open ↗
08/26/2026B01094442-P1Open ↗
08/24/2026B01094442-I1Open ↗
Showing 3 of 5 on file for this type
▸Safety & Tenant Protection7
▸DOB NOWStreet Tree Checklist6
08/17/2026B01094442-I1Open ↗
08/15/2026B01094442-P5Open ↗
08/13/2026B01094442-P4Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B01094442-I1Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/21/2026B01094442-P1Open ↗
08/21/2026B01094442-P4Open ↗
08/17/2026B01094442-S1Open ↗
Showing 3 of 8 on file for this type
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
03/17/2025322118702Open ↗
▸Other Documents8
▸DOB NOWProperty Ownership Certification4
08/21/2026B01094442-P4Open ↗
08/21/2026B01094442-P1Open ↗
08/17/2026B01094442-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWWaiver Document3
08/13/2026B01094442-P5Open ↗
08/13/2026B01094442-I1Open ↗
08/13/2026B01094442-P4Open ↗
▸BISPLOT DIAGRAM1
04/16/2025322118702Open ↗