DOB02/18/2026BOROUGH COMMISSIONER STOP WORK ORDER APPLICATION #121167236DUE TO APPLICANT WITHDRAWAL.
DOB02/05/2026DOB HEARS YOU TO STOP ALL WORK UNDER JOB # 120077530
DOB01/28/2026FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. OBSERVED DAMAGED DEFECTIVE CORNICE IN MULTIPLE LOCATIONS ON ALL EXPOSURE. ALSO DAMAGED MORTAR JOINTS IN MULTIPLE LOCATIONS ON ALL EXPOSURES. REMEDY: REPAIR AND OR REPLACE
ECB09/05/2025AT TIME OF INSPECTION, OBSERVED BUILDING STILL IN STATE OF DISREPAIR WITH MISSING MORTAR AND SHINGLES AT ROOF, STEP CRACKS AND BULGING BRICK AT EXPOSURE 2. DAMAGED BUILDING NON COMPLIANT WITH CODE., REPAIR AND/$3K due
DOB06/24/2025FAILURE TO MAINTAIN BUILDING FACADE & APPURTENANCES IN A CODE COMPLIAN T MANNER.AT TIME OF INSPECTION,IT WAS OBSERVED THROUGHOUT THE BUILDING SPALLING BRICKS,DETERIORATED MORTAR JOINTS.AT EXP1&3 SOUTH & NORTH ELE V,DAMAGED METAL CORNICES WERE OBSERVED.AT EXP2 WEST ELEV,BULDGING WALL ,CRACKS,SPALLING & LOOSE BRICK WERE OBSERVED.REMEDY:REPAIR OR REPLACE
DOB02/12/2025FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED SEVERLY HANGING/DAMAGED METAL CORNICE AT EXPOSURES 1 & 3 (NORTH & SOUTH ELEVS) & AT EXPOSURES 2 & 4 (EAST & WEST ELEVATIONS) SPALLING/CRACKED MASONRY AND DETERIORATED MORTAR JOINTS WAS ALSO OBSERVED. REMEDY: REPAIR AND/OR REPLACE
DOB11/06/2024EMEGRENCY WORK ORDER.AT SOUTH/EAST CORNER PARAPET WALL HAS MISSING TERRACOTA PIECES,DIAGONAL CRACK IS VISBIBLE FROM BASE TO PARAPET PIECES OF PARAPET ARE NOT PROPERLY SUPPORTED.OWNR TO IMMED HIRE A NYSPE&DOB CNTRCTR TO EVAL PARAPETS & PRFRM STBILIZATN@UNSFE CNDITIONS PRSUANT TO NYCAC-28.105.4.1
DOB09/10/2024FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED MISSING DAMAGED MORTAR JOINTS IN MULT. LOCATIONS. HAIRLINE CRACKS ON BRICK FACADE & CRACKS OF STONE FACADE AT EXPOSURES 1,3,4.DAMAGED CORNICE OBSERVED THROUGHOUT BUILDING. DAMAGED STATE TILE ON ROOF AT EXPOSURE # 4.CRACK AT PARAPET LEVEL. REMEDY: REPLACE AND/OR REPAIR
DOB06/23/2024FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2023)
DOB04/09/2024FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. MISSING & DAMAGED MORTAR JOINTS IN MULTIPLE LOCATIONS.HAIRLINE CRACKS ON BRICK FACADE & CRACKS OF STONE FACADE @ EXP1,3,4 DAMAGED CORNICE ALL THROUGHOUT BLDG DAMAGED SLATE TILE ON ROOF. EXP#4 LARGE CRACK @ PARAPET LVL, STEP CRACKS. MISSING MORTAR JOINTS. REMEDY: REPAIR AND/OR REPACE
DOB02/22/2024FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB12/01/2023FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
DOB11/22/2023FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB11/15/2023FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB11/02/2023FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB08/02/2023FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
ECB07/14/2023OBSERVED BUILDING EXTERIOR WALL IN STATE OF DISREPAIR AND MISSING ROOF SHINGLES AT DORMER, AND IS TEMP COVERED WITH TARP AT DORMER. ALSO ROOF FLASHING.$5K due
DOB05/02/2023FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB04/22/2023FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2022
DOB02/02/2023FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB12/06/2022RE-SEAL BLDG W/MASONRY CONCRETE BLOCK SEAL AT ALL EXTERIOR OPENINGS INCLUDING PENETRATIONS THROUGH SWS &COURTYARDS & INCLUDING DOOR&WINDOW OPENINGS @CELLAR &1STORY.SEAL ALL ROOF OPENINGS,INCLUDING MECHANICAL EQUIPMENT PENETRATIONS, SKYLIGHTS & BULHEAD.REMOVE ALL LOOSE GLASS,SAS HES &WINDOW FRAMES FROM ALL WINDOW OPENINGS WHICH DONOT REQUIRE SEAL
DOB12/05/2022INSTALL NETTING AT DORMERS TO AVIOD FALLING DEBRIS FROM BUILDING FACADE INTO INTERIOR COURT YARDS
DOB12/01/2022FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
DOB11/02/2022FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB08/02/2022FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB07/28/2022.SEAL SIDEWALK OPENING TO SAFEGUARD THE PUBLIC AND PROPERTY
DOB07/28/2022V-DOB VIOLATION - ACTIVE
DOB06/01/2022FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB02/02/2022FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB12/01/2021FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
DOB11/02/2021FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB09/15/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB08/02/2021FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB07/01/2021V-DOB VIOLATION - ACTIVE
DOB06/04/2021FTM EXTERIOR BUILDING WALL AND APPURTENANCES. OBSERVED ON EXP 1 BROKEN WINDOW PANES AT SEVERAL FLOORS AND SEVERAL LOCATIONS. EXP 4 CRACKS OPEN MORTAR JOINTS AT PARAPET COPING STONES. SOUTH EAST END OF PARAPET. REMEDY: MAINTAIN EXTERIOR BUILDING WALLS, PROVIDE ADEQUATE SAFETY MEASURES, REPAIR DAMAGED FACADE AS PER 1RCNY 103-04
DOB06/02/2021FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB04/29/2021FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
DOB02/03/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB02/02/2021FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB12/23/2020FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB11/02/2020FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB09/02/2020FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB08/02/2020FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB05/02/2020FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB11/27/2019FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB08/08/2019ADD'L INFORMATION REQ:VIO#061319FEU10301FF,OLD STRUCT REPT DTD 3/18/19 REQ EMERG STABL OF FACADE INCLUDING BRACING/STRAPPING/SEALING OF LOOSE CRACK,DETACHED FACADE ROOF/CORNICE/ELEMENTS.OWNR IMMD PROVIDE SIDEWALK CLOSURE T/B/F UND PRMT ALONG FACADE@EAST 9TH ST.& EAST 10TH ST. TO THE SAME SPECIFICATIONS AS IF BC.3306.2.1 WERE APPLICABLE
DOB08/08/2019ADD'L INFORMATION:REQUIRED:VIO #061319FEU10301FF,OLD STRUCTURE REPORT DTD 3/18/19 REQ EMERG STABL OF FACADE INCLUD BRACING/STRAPPING/SEALING OF LOOSE,CRACKED,DETACHED FACADE/ROOF/CORNICE/ELEMENTS.PURSUANT TO 28- 104.7.11.OWN RETAIN PE NYS SURVEYOR TO DEVELOP MONITOR PROGRAM PROVIDE WEEKLY TRANSIT MONITOR REPORTS WITH PE REPORTS
DOB08/08/2019FAILURE TO COMPLY:VIO#050119FEU10301FF.IMMED STABL OF UNSAFE STRCTL CONDN@FACADE&STABL WRK WERE TO STRT N/L/THAN 5/28/19&BE CMPL N/L/THAN 6/28/19.NO WRK HAS START AS 8/8/19.REPT DTD 3/18/19 REQ EMERG STABL OF THE FACADE INCLUD BRACE/STRAPPING/SEALING OF LOOSE CRACK,DETACH,FACADE ROOF/CORNICE ELMNTS.COMPLY W COMMISH ORD #050119FEU10301FF CTL#315717
DOB06/26/2019FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB06/13/2019ADD'L INFO REQD:5ST+C,LNDMRK,REF TO DOB VIO 3/1/19&3/18/19 OLD STRUCT REPORT DEFECTS AT FACADE;DIAGIONAL CRACKS@ N/E+S/E WALLS,MOVEMENT @S/E WALL,FACADE DETACHED&ROOFING MISSING&CRACKS ON CHIMNEY.OWN MUST ENGAGE PE&SURVEYOR TO DEVELOP A MONITOR PROGRAM FOR BUILDING FACADE PROVIDE REPORTS OF FACADE CONDITIONS WITH ENGINEERING RECOMMENDATIONS TO DOB
DOB05/16/2019FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB05/01/2019FTM:5ST+C LNDMRK.DOB# 315701 & 3/18/19 OLD STRUC REPRT REQ EMRG STABIL OF FAC.DEFECTS:DIAG CRKS,MOVMT,ELEMENTS DETACH, STN & RFG MISSING,CRKS ON CHIMNEY.EMRGWRK:OWN IMMED ENG PE & DOB LIC CONTR TO STABILIZ UNSAFE CONDS @FAC PURSUANT TO 28-105.4.1 WORK CONT SUPERVISED BY PE.STRT WRK N/L/THAN 5/28/19 &COMPL 6/28/19. FILE FOR PERMIT 2 DAYS AFTER START
DOB04/05/2019VIOLATION ISSUED TO ELEVATOR - FAILURE TO FILE CATEGORY 1 2017 INSPECTION/TEST
DOB03/01/2019FAILURE TO MAINTAIN. BUILDING IS A 5 STORY + CELLAR, "H" SHAPE "SNYDER TYPE", 150' X 183' +/- LANDMARK BUILDING ON THRU LOT 150' X 185' +/- IT WAS A SCHOOL (OLD PS 64) BUILT AROUND 1902 AND WAS UNOCCUPIED FOR 18 YEARS WITHOUT MAINTENANCE. DISCOVERED DURING INSPECTION THAT THE BU ILDING WAS STRIPPED OF ARCHITECTURAL FINISHES, FIRE PROOFING AND ON EA
DOB03/01/2019FAILURE TO MAINTAIN. BUILDING IS A 5 STORY + C, "H" SHAPE "SNYDER TYPE ", 150' X 183' +/- LANDMARK BUILDING ON THIS LOT 105' X 185' +/-. IT W AS A SCHOOL (OLD PS 64) BUILT AROUND 1902 AND WAS UNOCCUPIED FOR 18YRS WITHOUT MAINTENANCE. AT A MIN., CRACKS OBSERVED AT NE, NW AND SE CORN ER OF BUILDING HAVE STARTED TO BE DETACHED FROM BACK UP WALLS, GAS 1"-
DOB02/16/2019FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB02/06/2019FTM:5ST+C BLDG ON THRU LOT IT WAS A SCHOOL PS 64 BLDG UNOCCUP 18 YRS W/O MAINTENANCE DISCOVERED DURING INSP 2/6/19 THE BLDG WAS STRIPPED OF ARCH.FINISHES,FIRE PROOF&ELECT ON 2-5FLS&FILLER BEAMS EXPOSED CRACKS OBSERVED ON E-W WALLS FROM 3 ROOF OWN HIRE PE EVAL COND OF INTR OF THE BLDG PROV RPT/W FINDING,RECOMMEND&LIST OF HAZARDS N/L/THAN 2/25/19
DOB02/06/2019FTM:5ST+C ON THRU LOT IT WAS A SCHOOL (PS64) BLDG UNOCCUPIED 18 YRS W/O MAINTENANCE@A MIN CRACKS OBSERVED ON E-W WALLS NEAR N-S WALLS FROM 3FL TO ROOF FLS.ORNAMENTAL STONE FACADE STARTED TO DETACH FROM BACK UP WALLS.CHIMNEY CRACKED@ROOF OWN HIRE PE EVAL CONDITIONS OF FACADE PRVD RPT W/FINDINGS,RECOMMENDATIONS&LIST OF HAZARDS NO LATER THAN 2/25/19
DOB02/02/2018FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB11/02/2017FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB08/02/2017FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB05/02/2017FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB02/03/2017FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB11/03/2016FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB08/03/2016FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB06/02/2016FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB02/02/2016FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB11/02/2015FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB08/06/2015BORO-COMM HAS ISSUED A LETTER OF INTENT TO REVOKE PERMIT 121329801 AS ON SEPT 22/2014 REMEDY: STOP ALL WORK
DOB08/02/2015FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB05/02/2015FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB06/06/2014FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB06/03/2013FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB05/03/2012FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB01/01/2012FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB10/08/2010V-DOB VIOLATION - ACTIVE
DOB11/23/2009STOP ALL WORK FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY ATTACHED B Y CONSTRUCTION OPERATIONS AT TIMEOF INSPECTION I DID OBSERVE GAS CYLIN DER NOT STORED PRPERTY SEVERAL FIRE EXTINGUISHERS NOT CHARGED REMEDY: STOP ALL WORK SAFEGUARD PUBLIC AND PROPERTY
DOB09/26/2008V-DOB VIOLATION - ACTIVE
ECB07/28/2022FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MATTER. NOTED: ON EAST 9 ST. SIDE OF BUILDING BILCO DOOR LEADING TO SIDEWALK VAULT OF BUILDING IS BROKEN AND PEOPLE COULD ENTER OR FALL IN WHEN WALKING ON SIDEWALKNothing owed — awaiting certificate of correction
ECB06/14/2021OBSERVED BUILDING EXTERIOR WALLS INSTATE OF DISREPAIR WITH DETERIORATED AND MISSING ROOF SHINGLES & TEMPORARY TARP COVERING OVER THE DORMER. ALSO PARTIALLY DETACHED & DISREPAIR ROOF FLASHING & BROKEN WINDOW GLANothing owed — awaiting certificate of correction
ECB11/05/2020FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. NOTED: BUILDING EXTERIOR WALLS IN DISREPAIR WITH DETERIORATED AND MISSING ROOF SHINGLES, ALSO PARTIALLY DETACHED FLASHING AT EXPOSURE #1 5TH STORY LEVEL.Nothing owed — awaiting certificate of correction
ECB09/21/2020FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MATTER. NOTED: EXPOSURE ONE FRONT OF BUILDING, OPENING IN SIDE WALK 2FEET X1 FOOT WIDE LEADING INTO THE VAULT OF VACANT BUILDING WHERE PEOPLE COULD ENTER OR FALL INothing owed — awaiting certificate of correction
ECB03/06/2020FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED SEVERAL CRACKS TO THE BRICKS AT EXPOSURE #3, AND SEVERE CRACKS SEPARATING THE STONE FROM THE BRICK AT EXPOSURE #4. NON COMPNothing owed — awaiting certificate of correction
ECB03/06/2020TEMPORARY CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT. AT TIME OF INSPECTION OBSERVED A SIDEWALK SHED ERECTED AT EXPOSURE #1. HOWEVER, THE PERMIT FOR THE SHED HAD EXPIRED ON 2/21/2020. NON COMPLIANT TO CODE.,Nothing owed — awaiting certificate of correction
ECB08/31/2019FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED: AT EXP#3 DECORATIVE MASONRY HAS BEEN REMOVED EXPOSING BRICK/MORTAR BECOMING LOOSE/DISLODGED. PREVIOUS ECB#35434283P. REMEDY: MAINTAIN EXTERIOR BLDG WALLS.Nothing owed — awaiting certificate of correction
ECB06/08/2019FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES.NOTE:AT 10TH STREET SIDE OF BUILDING EXPOSURE #3 DECORATIVE MASONRY HAS BEEN REMOVED EXPOSING BRICKS THAT MAY BECOME DISLODGED ALSO THROUGH OUT ENTIRE BUILDING BRNothing owed — awaiting certificate of correction
ECB03/30/2019FAILURE TO MAINTAIN BLDG WALLS & APPURTENANCES. AT TIME OF INSPECTION.NOTED AT 10TH ST SIDE OF BLDG-AT 5TH FL. 11 LOCATIONS WHERE DECORATIVEORNAMENTAL MASONRY HAS BEEN REMOVED LEAVING EXPOSED BRICK SOME OF WHICNothing owed — awaiting certificate of correction
ECB02/06/2019FAILURE TO MAINTAIN BUILDING WALLS AND APPURTENANCES IN A CODE COMPLIANT MANNER. AT TIME OF INSPECTION NOTED LARGE CRACK 1" TO 1/2" IN WIDTHAT BUILDING FRONT FROM 5TH FL TO 3RD FL EXP 2&4. ADDITIONALLY LOOSE STNothing owed — awaiting certificate of correction
ECB12/30/2016FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER,NOTED: AT THE TIME OF INSPECITON OBSERVED CRACKS ON THE PARAPET WALL OF THE WEST ELEVATION.APPROX 1/2"WIDTH AND AROUND 6'LONG,WHICH WOULD POSSESS A HAZNothing owed — awaiting certificate of correction
ECB02/05/2013FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER: NOTED DEFECTS AT ABOVE 3RD FLR. BELOW DORMER, CENTER COURT LOOSE COPPER FLASHING UNDER DORMER , ALSO NOTE LOOSE COPPER BELOW WEST DORMER AT EXP 1 & BROKENNothing owed — awaiting certificate of correction
ECB01/31/2013FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER AT BLDG WALL(S) OR APPURTENANCES.1-AT FRONT FACADE EXPOSURE 1 AT 5TH FLOOR LEVEL COPPER TRIM HAS DISLODGED AND FLAPPING.RMDY:MAINTAIN BLDG EXTERIOR WALLS &/Nothing owed — awaiting certificate of correction
ECB09/02/2011FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLAINT MANNER. NOTED: AT THE NORTH FACADE AT 5 FLOOR THE PERIMETER MASONRY PIECES HAVE BEEN REMOVED LEAVING LOOSE BRICK WORK. AT NORTH-EAST CORNER AT 5GL CRACKS EXISTNothing owed — awaiting certificate of correction