← Back
Walk-up apt, over six families with stores
350 EAST 92 STREET
MANHATTAN · Upper East Side-Yorkville · BIN 1050221
💬 Discuss this project
1910Year Built
5Stories
C7Building Class
C2-8Zoning
8,142 sfGross Floor Area
12Units
Rent Stabilized7 Open Violations ▸
Walk-up apt, over six families with stores · Owner of record: ZAHARIS REALTY, LLC · 1,925 sf lot · 4.23 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingGeneral
Floor 512p · 1 filing · 20 docs
Floor 412p · 1 filing · 20 docs
Floor 312p · 1 filing · 20 docs
Floor 212p · 1 filing · 20 docs
Floor 115p · 1 filing · 20 docs
Cellar15p · 1 filing · 20 docs
Site & exterior20p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ZAHARIS REALTY3707/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
WAYPOINT CONSULTING GROUP509/29/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TEKA ENTERPRISES INCGeneral Contractor507/08/2026
TEMPEST ELEC'L CONTRG, INElectrical203/22/2026
DELTA-SIGMA MECH CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
WAYPOINT CONSULTING GROUP6175409/29/2025
AA BUILDING & INSPECTION1519101/08/2025
Building Lifecycle
All (62)Filed (5)Permit Issued (6)Signed Off (2)Violation (17)Inspection (2)Special Inspection (30)
07/13/2026
Signed off — Alteration
Temporary construction fence in front of existing retail space related to the installation of New Storefront System filed under application No. M01115523-I1
M01115523-I1
04/30/2026
Permit issued — General Construction
M01115523-I1-GC-CX
02/02/2026
Signed off — Alteration
Temporary construction fence in front of existing retail space related to the installation of New Storefront System filed under application No. M01115523-I1
M01115523-S2
01/08/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
09/30/2025
Special inspection requirement — Interior lighting power
Alejandro Molina
09/30/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Alejandro Molina
09/30/2025
Special inspection requirement — Air barrier - visual inspection
Alejandro Molina
09/30/2025
Special inspection requirement — Permanent certificate
Alejandro Molina
09/30/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Alejandro Molina
09/30/2025
Special inspection requirement — Maintenance information
Alejandro Molina
09/30/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Younes Abouyaala
09/30/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Alejandro Molina
09/30/2025
Special inspection requirement — Post-installed Anchors
Alejandro Molina
09/30/2025
Special inspection requirement — Tenant Protection Plan Compliance
Alejandro Molina
09/30/2025
Special inspection requirement — Concrete - Cast-In-Place
Alejandro Molina
09/30/2025
Special inspection requirement — Mechanical Systems
Alejandro Molina
09/30/2025
Special inspection requirement — Final
Alejandro Molina
09/30/2025
Special inspection requirement — Fire-Resistance Rated Construction
Alejandro Molina
09/30/2025
Special inspection requirement — Energy Code Compliance Inspections
Alejandro Molina
09/30/2025
Special inspection requirement — HVAC-R and service water heating equipment
Alejandro Molina
09/30/2025
Special inspection requirement — HVAC-R and service water heating system controls
Alejandro Molina
09/29/2025
Filed — Alteration
Temporary construction fence in front of existing retail space related to the installation of New Storefront System filed under application No. M01115523-I1
M01115523-P2
09/23/2025
Special inspection requirement — Tenant Protection Plan Compliance
Alejandro Molina
09/09/2025
Special inspection requirement — Maintenance information
Alejandro Molina
09/09/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Alejandro Molina
09/09/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Alejandro Molina
09/09/2025
Special inspection requirement — Mechanical Systems
Alejandro Molina
09/09/2025
Special inspection requirement — Post-installed Anchors
Alejandro Molina
09/09/2025
Special inspection requirement — Concrete - Cast-In-Place
Alejandro Molina
09/09/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
09/09/2025
Special inspection requirement — Energy Code Compliance Inspections
Alejandro Molina
09/09/2025
Special inspection requirement — Final
Alejandro Molina
09/09/2025
Special inspection requirement — Fire-Resistance Rated Construction
Alejandro Molina
09/09/2025
Special inspection requirement — HVAC-R and service water heating equipment
Alejandro Molina
09/09/2025
Special inspection requirement — Permanent certificate
Alejandro Molina
07/17/2025
Permit issued — Mechanical Systems
M01115523-I1-GC-CX
07/14/2025
Permit issued — Construction Fence
M01115523-S2-FN
07/07/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/01/2025
Filed — Alteration
Temporary construction fence in front of existing retail space related to the installation of New Storefront System filed under application No. M01115523-I1
M01115523-P1
05/28/2025
Permit issued — Construction Fence
M01115523-S2-FN
04/08/2025
Permit issued — Plumbing
M01115523-S1-PL
04/02/2025
Filed — Alteration
Temporary construction fence in front of existing retail space related to the installation of New Storefront System filed under application No. M01115523-I1
M01115523-S2
04/02/2025
Filed — Alteration
Temporary construction fence in front of existing retail space related to the installation of New Storefront System filed under application No. M01115523-I1
M01115523-S1
02/06/2025
Permit issued — General Construction
M01115523-I1-GC-CX
01/08/2025
Filed — Alteration
Temporary construction fence in front of existing retail space related to the installation of New Storefront System filed under application No. M01115523-I1
M01115523-I1
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/16/2020
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/05/2018
Violation issued (HPD, closed)
I
11/30/2009
Violation issued (ECB, closed)
Signs
11/30/2009
Violation issued (ECB, closed)
Signs
11/30/2009
Violation issued (ECB, closed)
Signs
11/30/2009
Violation issued (ECB, closed)
Signs
11/30/2009
Violation issued (ECB, closed)
Signs
04/28/2009
Violation issued (ECB, closed)
Boilers
08/20/2007
Violation issued (ECB, closed)
Boilers
Latest 60 of 62 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offTEKA ENTERPRISES INC04/30/2026
DOB NOWMechanical SystemsSigned-offTEKA ENTERPRISES INC07/17/2025
DOB NOWConstruction FenceSigned-offTEKA ENTERPRISES INC07/14/2025
DOB NOWConstruction FenceSigned-offTEKA ENTERPRISES INC05/28/2025
DOB NOWPlumbingSigned-offDELTA-SIGMA MECH CORP04/08/2025
DOB NOWGeneral ConstructionSigned-offTEKA ENTERPRISES INC02/06/2025
BISOTISSUEDAKA PEST CONTROL, INC05/11/2016
BISPLISSUEDMETROCITY GROUP,INC05/31/2012
BISPLISSUEDMETROCITY GROUP,INC04/06/2011
BIS—ISSUEDPETER'S RESTORATION CORP03/25/2011
BISEQISSUEDNEW J.D. GEN. CONSTR. INC07/19/2010
BISFBISSUEDJACK PICCINI, INC09/04/2008
BIS—ISSUEDMN CONSTRUCTION CORP04/15/2008
BISPLISSUEDKAPNAG HTG & PLBG CORP.03/05/2008
BIS—ISSUEDMN CONSTRUCTION CORP02/22/2008
BISOTISSUEDNORTH SHORE NEON SIGN LLC07/31/2007
BISOTISSUEDNORTH SHORE NEON SIGN LLC07/31/2007
BISOTISSUEDABC MACHINERY CORP.02/09/1999
1 project · most recent 09/29/2025
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
09/29/2025Signed-offTEKA ENTERPRISES INCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric PEAD-A24AA7 24,000 BTU · Vrf Indoor ×4
MXZ-SM96TAM-U1 96,000 BTU · Condensing Unit ×2
PEAD-A18AA7 18,000 BTU · Vrf Indoor ×2
PEAD-A30AA7 30,000 BTU · Fan Coil Indoor ×2
1 project · most recent 09/29/2025
Water/Sanitary
FiledStatusContractorScope
09/29/2025Signed-offDELTA-SIGMA MECH CORPWater/Sanitary
3 projects · most recent 01/25/2026
General Wiring
FiledStatusContractorScope
01/25/2026Permit IssuedTEMPEST ELEC'L CONTRG, IN19 meters, 4 new_meters
10/20/2025Permit IssuedTEMPEST ELEC'L CONTRG, INGeneral Wiring
06/01/2025Permit IssuedTEMPEST ELEC'L CONTRG, INGeneral Wiring
1 project · most recent 09/29/2025
Fence
FiledStatusContractorScope
09/29/2025Signed-offTEKA ENTERPRISES INCFence
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
01/08/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/07/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 40
DateRequirementInspectorRole
09/30/2025Interior lighting powerAlejandro Molinaenergy_progress
09/30/2025HVAC-R and service water piping design and insulationAlejandro Molinaenergy_progress
09/30/2025Air barrier - visual inspectionAlejandro Molinaenergy_progress
09/30/2025Permanent certificateAlejandro Molinaenergy_progress
09/30/2025Fenestration and door U-factor and product ratingsAlejandro Molinaenergy_progress
09/30/2025Maintenance informationAlejandro Molinaenergy_progress
09/30/2025Structural Stability – Alterations of existing buildingsYounes Abouyaalaspecial
09/30/2025Fire-Resistant Penetrations and JointsAlejandro Molinaspecial
09/30/2025Post-installed AnchorsAlejandro Molinaspecial
09/30/2025Tenant Protection Plan ComplianceAlejandro Molinaspecial
09/30/2025Concrete - Cast-In-PlaceAlejandro Molinaspecial
09/30/2025Mechanical SystemsAlejandro Molinaspecial
09/30/2025FinalAlejandro Molinaprogress
09/30/2025Fire-Resistance Rated ConstructionAlejandro Molinaprogress
09/30/2025Energy Code Compliance InspectionsAlejandro Molinaprogress
09/30/2025HVAC-R and service water heating equipmentAlejandro Molinaenergy_progress
09/30/2025HVAC-R and service water heating system controlsAlejandro Molinaenergy_progress
09/23/2025Tenant Protection Plan ComplianceAlejandro Molinaspecial
09/09/2025Maintenance informationAlejandro Molinaenergy_progress
09/09/2025Fenestration and door U-factor and product ratingsAlejandro Molinaenergy_progress
09/09/2025Fire-Resistant Penetrations and JointsAlejandro Molinaspecial
09/09/2025Mechanical SystemsAlejandro Molinaspecial
09/09/2025Post-installed AnchorsAlejandro Molinaspecial
09/09/2025Concrete - Cast-In-PlaceAlejandro Molinaspecial
09/09/2025Structural Stability – Alterations of existing buildings—special
Latest 25 of 40.
▾Documents — 66 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/24/2026M01115523-I1Request digital key ↗
08/24/2026M01115523-S1Request digital key ↗
08/24/2026M01115523-P2Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits8
▸BISPLAN / WORK APPROVAL APPLICATION4
04/29/2016122446264Open ↗
08/07/2014120398596Open ↗
07/01/2010120398596Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION4
05/24/2016122446264Open ↗
07/22/2010120398596Open ↗
09/04/2008110320787Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications30
▸DOB NOWSpecial Inspector Seal & Signature11
09/19/2026M01115523-P2Open ↗
09/19/2026M01115523-P2Open ↗
08/29/2026M01115523-I1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/24/2026M01115523-S1Open ↗
08/24/2026M01115523-I1Open ↗
08/13/2026M01115523-P2Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
07/21/2016122446264Open ↗
04/29/2016122446264Open ↗
07/02/2013120398596Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/19/2026M01115523-P2Open ↗
09/19/2026M01115523-P2Open ↗
08/29/2026M01115523-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
04/29/2016122446264Open ↗
07/01/2010120398596Open ↗
09/03/2008110320787Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
07/01/2010120398596Open ↗
09/03/2008110320787Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
04/29/2016122446264Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
09/03/2008110320787Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
04/29/2016122446264Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/24/2026M01115523-S1Open ↗
08/24/2026M01115523-I1Open ↗
08/13/2026M01115523-P2Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
07/01/2010120398596Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
09/03/2008110320787Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
07/21/2016122446264Open ↗
04/29/2016122446264Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
07/21/2016122446264Open ↗
▸Approvals, Objections & Sign-offs6
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
07/21/2016122446264Open ↗
07/02/2013120398596Open ↗
08/18/2009110320787Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
07/01/2010120398596Open ↗
09/03/2008110320787Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
08/18/2009110320787Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
07/21/2016122446264Open ↗
04/29/2016122446264Open ↗
▸Filing & Intake Forms3
▸BISEFILING COVER SHEET2
04/29/2016122446264Open ↗
07/01/2010120398596Open ↗
▸BISeFiling Job Application Cover Sheet1
09/03/2008110320787Open ↗
▸Other Documents1
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
07/02/2013120398596Open ↗