| Owner | Filings | Most Recent |
|---|---|---|
| ZAHARIS REALTY | 37 | 07/08/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| WAYPOINT CONSULTING GROUP | 5 | 09/29/2025 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| TEKA ENTERPRISES INC | General Contractor | 5 | 07/08/2026 |
| TEMPEST ELEC'L CONTRG, IN | Electrical | 2 | 03/22/2026 |
| DELTA-SIGMA MECH CORP | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| WAYPOINT CONSULTING GROUP | 6175 | 4 | 09/29/2025 |
| AA BUILDING & INSPECTION | 1519 | 1 | 01/08/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Signed-off | TEKA ENTERPRISES INC | 04/30/2026 |
| DOB NOW | Mechanical Systems | Signed-off | TEKA ENTERPRISES INC | 07/17/2025 |
| DOB NOW | Construction Fence | Signed-off | TEKA ENTERPRISES INC | 07/14/2025 |
| DOB NOW | Construction Fence | Signed-off | TEKA ENTERPRISES INC | 05/28/2025 |
| DOB NOW | Plumbing | Signed-off | DELTA-SIGMA MECH CORP | 04/08/2025 |
| DOB NOW | General Construction | Signed-off | TEKA ENTERPRISES INC | 02/06/2025 |
| BIS | OT | ISSUED | AKA PEST CONTROL, INC | 05/11/2016 |
| BIS | PL | ISSUED | METROCITY GROUP,INC | 05/31/2012 |
| BIS | PL | ISSUED | METROCITY GROUP,INC | 04/06/2011 |
| BIS | — | ISSUED | PETER'S RESTORATION CORP | 03/25/2011 |
| BIS | EQ | ISSUED | NEW J.D. GEN. CONSTR. INC | 07/19/2010 |
| BIS | FB | ISSUED | JACK PICCINI, INC | 09/04/2008 |
| BIS | — | ISSUED | MN CONSTRUCTION CORP | 04/15/2008 |
| BIS | PL | ISSUED | KAPNAG HTG & PLBG CORP. | 03/05/2008 |
| BIS | — | ISSUED | MN CONSTRUCTION CORP | 02/22/2008 |
| BIS | OT | ISSUED | NORTH SHORE NEON SIGN LLC | 07/31/2007 |
| BIS | OT | ISSUED | NORTH SHORE NEON SIGN LLC | 07/31/2007 |
| BIS | OT | ISSUED | ABC MACHINERY CORP. | 02/09/1999 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 09/29/2025 | Signed-off | TEKA ENTERPRISES INC | Heating and Air Conditioning Systems | Heat / Cool Mitsubishi Electric PEAD-A24AA7 24,000 BTU · Vrf Indoor ×4 MXZ-SM96TAM-U1 96,000 BTU · Condensing Unit ×2 PEAD-A18AA7 18,000 BTU · Vrf Indoor ×2 PEAD-A30AA7 30,000 BTU · Fan Coil Indoor ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/29/2025 | Signed-off | DELTA-SIGMA MECH CORP | Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 01/25/2026 | Permit Issued | TEMPEST ELEC'L CONTRG, IN | 19 meters, 4 new_meters |
| 10/20/2025 | Permit Issued | TEMPEST ELEC'L CONTRG, IN | General Wiring |
| 06/01/2025 | Permit Issued | TEMPEST ELEC'L CONTRG, IN | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/29/2025 | Signed-off | TEKA ENTERPRISES INC | Fence |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 09/30/2025 | Interior lighting power | Alejandro Molina | energy_progress |
| 09/30/2025 | HVAC-R and service water piping design and insulation | Alejandro Molina | energy_progress |
| 09/30/2025 | Air barrier - visual inspection | Alejandro Molina | energy_progress |
| 09/30/2025 | Permanent certificate | Alejandro Molina | energy_progress |
| 09/30/2025 | Fenestration and door U-factor and product ratings | Alejandro Molina | energy_progress |
| 09/30/2025 | Maintenance information | Alejandro Molina | energy_progress |
| 09/30/2025 | Structural Stability – Alterations of existing buildings | Younes Abouyaala | special |
| 09/30/2025 | Fire-Resistant Penetrations and Joints | Alejandro Molina | special |
| 09/30/2025 | Post-installed Anchors | Alejandro Molina | special |
| 09/30/2025 | Tenant Protection Plan Compliance | Alejandro Molina | special |
| 09/30/2025 | Concrete - Cast-In-Place | Alejandro Molina | special |
| 09/30/2025 | Mechanical Systems | Alejandro Molina | special |
| 09/30/2025 | Final | Alejandro Molina | progress |
| 09/30/2025 | Fire-Resistance Rated Construction | Alejandro Molina | progress |
| 09/30/2025 | Energy Code Compliance Inspections | Alejandro Molina | progress |
| 09/30/2025 | HVAC-R and service water heating equipment | Alejandro Molina | energy_progress |
| 09/30/2025 | HVAC-R and service water heating system controls | Alejandro Molina | energy_progress |
| 09/23/2025 | Tenant Protection Plan Compliance | Alejandro Molina | special |
| 09/09/2025 | Maintenance information | Alejandro Molina | energy_progress |
| 09/09/2025 | Fenestration and door U-factor and product ratings | Alejandro Molina | energy_progress |
| 09/09/2025 | Fire-Resistant Penetrations and Joints | Alejandro Molina | special |
| 09/09/2025 | Mechanical Systems | Alejandro Molina | special |
| 09/09/2025 | Post-installed Anchors | Alejandro Molina | special |
| 09/09/2025 | Concrete - Cast-In-Place | Alejandro Molina | special |
| 09/09/2025 | Structural Stability – Alterations of existing buildings | — | special |