← Back
Three families
3562 CARLISLE PLACE
BRONX · Williamsbridge-Olinville · BIN 2057761
💬 Discuss this project
1960Year Built
3Stories
C0Building Class
R6AZoning
3,076 sfGross Floor Area
3Units
Rent Stabilized19 Open Violations 18 unresolved · 1 paperwork only ▸FDNY Report ↗
Three families · Owner of record: 3562 CARLISLE LLC · 2,900 sf lot · 1.06 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Roof34p · 1 filing · 20 docs
Floor 334p · 1 filing · 20 docs
Floor 235p · 1 filing · 20 docs
Floor 135p · 1 filing · 20 docs
Site & exterior21p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
3562 CARLISLE LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/24/2025$1.0M—— → —$330/sf building
08/20/2018$710K—Private party → Private party$231/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LEANDRO NILS DICKSON ARCHITECT, LLC507/16/2026
VASILIOS ARTEMIOU PE712/31/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NYC DESIGN FILE1103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JHZ CONSULTING SERVICES *General Contractor907/08/2026
ACCURATE MECHANICAL INCFire Protection107/08/2026
RAPTOR MECHANICAL,INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SHAHRISH SHUVO ENGINEERIN85241207/16/2026
Building Lifecycle
All (147)Filed (12)Permit Issued (7)Signed Off (4)Violation (50)Inspection (10)Objection (34)Special Inspection (30)
08/10/2026
Signed off — Alteration CO
Filing plumbing drawing subsequent to primary job number X01059821-I1
X01059821-S5
07/17/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Shahrish Shuvo
07/17/2026
Special inspection requirement — Post-installed anchors in masonry
Shahrish Shuvo
07/17/2026
Special inspection requirement — Structural Wood Frame
Shahrish Shuvo
07/17/2026
Special inspection requirement — Structural Steel - Welding
Shahrish Shuvo
07/17/2026
Special inspection requirement — Structural Steel - Details
Shahrish Shuvo
07/17/2026
Special inspection requirement — Final
Jhonatan Diaz Santana
07/16/2026
Filed — Alteration CO
Filing plumbing drawing subsequent to primary job number X01059821-I1
X01059821-P7
07/16/2026
Special inspection requirement — Structural Steel - Details
07/16/2026
Special inspection requirement — Post-installed anchors in masonry
07/16/2026
Special inspection requirement — Structural Steel - Welding
07/13/2026
Special inspection requirement — Structural Wood Frame
Shahrish Shuvo
07/13/2026
Special inspection requirement — Final
Shahrish Shuvo
07/13/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Shahrish Shuvo
04/29/2026
Violation issued (HPD, open)
A
03/18/2026
Inspection — Pass-Final Construction Permit Withdrawal
Pass
View inspection ↗
03/17/2026
Signed off — Alteration CO
Filing plumbing drawing subsequent to primary job number X01059821-I1
X01059821-S2
02/13/2026
Signed off — Alteration CO
Filing plumbing drawing subsequent to primary job number X01059821-I1
X01059821-S3
02/02/2026
Special inspection requirement — Maintenance information
Shahrish Shuvo
02/02/2026
Special inspection requirement — Air barrier - visual inspection
Shahrish Shuvo
02/02/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Shahrish Shuvo
02/02/2026
Special inspection requirement — Metering
Shahrish Shuvo
02/02/2026
Special inspection requirement — Permanent certificate
Shahrish Shuvo
02/02/2026
Special inspection requirement — Fenestration air leakage
Shahrish Shuvo
02/02/2026
Special inspection requirement — Fenestration areas
Shahrish Shuvo
02/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Shahrish Shuvo
02/02/2026
Special inspection requirement — Energy Code Compliance Inspections
Shahrish Shuvo
02/02/2026
Special inspection requirement — Fire-Resistance Rated Construction
Shahrish Shuvo
02/02/2026
Special inspection requirement — Interior lighting power
Shahrish Shuvo
02/02/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Shahrish Shuvo
02/02/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
Shahrish Shuvo
02/02/2026
Special inspection requirement — Insulation placement and R values
Shahrish Shuvo
01/21/2026
Objection resolved — Addressed
01/21/2026
Objection resolved — Addressed
01/16/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Shahrish Shuvo
01/16/2026
Special inspection requirement — HVAC-R and service water heating system controls
Shahrish Shuvo
01/16/2026
Special inspection requirement — HVAC-R and service water heating equipment
Shahrish Shuvo
01/16/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Shahrish Shuvo
01/13/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/07/2026
Objection raised — Structural
01/07/2026
Objection raised — Other
12/31/2025
Filed — Alteration CO
Filing plumbing drawing subsequent to primary job number X01059821-I1
X01059821-P6
12/23/2025
Filed — Alteration CO
Filing plumbing drawing subsequent to primary job number X01059821-I1
X01059821-P5
12/19/2025
Filed — Alteration CO
Filing plumbing drawing subsequent to primary job number X01059821-I1
X01059821-P4
11/19/2025
Permit issued — Structural
X01059821-S5-ST
11/19/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/18/2025
Violation issued (HPD, closed)
I
11/13/2025
Filed — Alteration CO
Filing plumbing drawing subsequent to primary job number X01059821-I1
X01059821-S5
11/06/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
11/03/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
10/29/2025
Signed off — Alteration CO
Filing plumbing drawing subsequent to primary job number X01059821-I1
X01059821-S1
10/29/2025
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
09/24/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
09/16/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
09/16/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/16/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
09/09/2025
Permit issued — Mechanical Systems
X01059821-S1-MS
09/05/2025
Permit issued — General Construction
X01059821-I1-GC
08/27/2025
Objection raised — Admin
08/27/2025
Objection resolved — Addressed
Latest 60 of 147 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offJHZ CONSULTING SERVICES *11/19/2025
DOB NOWMechanical SystemsSigned-offJHZ CONSULTING SERVICES *09/09/2025
DOB NOWGeneral ConstructionPermit IssuedJHZ CONSULTING SERVICES *09/05/2025
DOB NOWPlumbingSigned-offRAPTOR MECHANICAL, INC07/21/2025
DOB NOWSprinklersSigned-offACCURATE MECHANICAL INC07/21/2025
DOB NOWGeneral ConstructionPermit IssuedJHZ CONSULTING SERVICES *07/10/2025
DOB NOWMechanical SystemsSigned-offJHZ CONSULTING SERVICES *07/03/2025
BIS—ISSUEDCAVA CONSTRUCTION CO. INC.04/27/1999
BISPLISSUEDG.N.T. MECHANICAL LLC04/27/1999
1 project · most recent 07/16/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/16/2026Signed-offJHZ CONSULTING SERVICES *Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Daikin FTXF18AXVJU 18,000 BTU · Fan Coil Indoor ×21
RXF12AXVJU 12,000 BTU · Condensing Unit ×20
FTXF12AXVJU 12,000 BTU · Split System ×18
RXF18AXVJU 18,100 BTU · Condensing Unit ×10
Ventilation
Nutone AEN110 50 CFM · Exhaust Fan ×10
QTXE110150DC 100 CFM · Exhaust Fan ×10
1 project · most recent 07/16/2026
Sprinkler System
FiledStatusContractorScope
07/16/2026Signed-offACCURATE MECHANICAL INCSprinkler System
1 project · most recent 07/16/2026
Gas Water/Sanitary
FiledStatusContractorScope
07/16/2026Signed-offRAPTOR MECHANICAL,INCGas, Water/Sanitary
2 projects · most recent 12/31/2025
General Wiring
FiledStatusContractorScope
12/31/2025CompleteACCURATE ELEC'L CORP.—
11/18/2025CompleteACCURATE ELEC'L CORP.General Wiring
1 project · most recent 07/16/2026
Wood
FiledStatusContractorScope
07/16/2026Signed-offJHZ CONSULTING SERVICES *Wood
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
03/18/2026Pass-Final Construction Permit WithdrawalPassView ↗
01/13/2026Pass-Final CND-Occupancy InspectionPassView ↗
11/19/2025Pass-Final CND-Occupancy InspectionPassView ↗
11/06/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
11/03/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
10/29/2025Fail-Final CND-Occupancy InspectionFailView ↗
09/24/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
09/16/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
09/16/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/16/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 78
DateRequirementInspectorRole
07/17/2026FinalJhonatan Diaz Santanaprogress
07/17/2026Structural Wood FrameShahrish Shuvoprogress
07/17/2026Post-installed anchors in masonryShahrish Shuvospecial
07/17/2026Structural Steel - DetailsShahrish Shuvospecial
07/17/2026Structural Stability – Alterations of existing buildingsShahrish Shuvospecial
07/17/2026Structural Steel - WeldingShahrish Shuvospecial
07/16/2026Structural Steel - Welding—special
07/16/2026Post-installed anchors in masonry—special
07/16/2026Structural Steel - Details—special
07/13/2026Structural Wood FrameShahrish Shuvoprogress
07/13/2026FinalShahrish Shuvoprogress
07/13/2026Structural Stability – Alterations of existing buildingsShahrish Shuvospecial
02/02/2026Permanent certificateShahrish Shuvoenergy_progress
02/02/2026Fire-Resistance Rated ConstructionShahrish Shuvoprogress
02/02/2026MeteringShahrish Shuvoenergy_progress
02/02/2026Energy Code Compliance InspectionsShahrish Shuvoprogress
02/02/2026Fire-Resistant Penetrations and JointsShahrish Shuvospecial
02/02/2026Exterior Insulation and Finish Systems (EIFS)Shahrish Shuvospecial
02/02/2026Structural Stability – Alterations of existing buildingsShahrish Shuvospecial
02/02/2026Interior lighting powerShahrish Shuvoenergy_progress
02/02/2026Fenestration air leakageShahrish Shuvoenergy_progress
02/02/2026Air barrier - visual inspectionShahrish Shuvoenergy_progress
02/02/2026Maintenance informationShahrish Shuvoenergy_progress
02/02/2026Insulation placement and R valuesShahrish Shuvoenergy_progress
02/02/2026Fenestration areasShahrish Shuvoenergy_progress
Latest 25 of 78.
▾Documents — 84 on file (BIS + DOB NOW)
▸Plans & Drawings12
▸DOB NOWPlans/Sketch12
08/19/2026X01059821-P1Request digital key ↗
08/19/2026X01059821-S3Request digital key ↗
08/19/2026X01059821-S2Request digital key ↗
Showing 3 of 12 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWHouse Number Verification: TOPO Stamp3
08/13/2026X01059821-P5Open ↗
08/13/2026X01059821-P3Open ↗
08/13/2026X01059821-I1Open ↗
▸Seals & Professional Certifications40
▸DOB NOWSpecial Inspector Seal & Signature15
09/01/2026X01059821-S1Open ↗
08/29/2026X01059821-P7Open ↗
08/28/2026X01059821-P3Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWProgress Inspector Seal & Signature13
09/01/2026X01059821-S1Open ↗
09/01/2026X01059821-S1Open ↗
08/29/2026X01059821-P7Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature12
08/19/2026X01059821-S3Open ↗
08/19/2026X01059821-S2Open ↗
08/19/2026X01059821-S1Open ↗
Showing 3 of 12 on file for this type
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist3
08/13/2026X01059821-I1Open ↗
08/13/2026X01059821-P5Open ↗
08/13/2026X01059821-P3Open ↗
▸Environmental & Asbestos23
▸DOB NOWDEP ACP-5: Asbestos Assessment Report12
08/19/2026X01059821-S3Open ↗
08/19/2026X01059821-S2Open ↗
08/19/2026X01059821-S1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWOER: Notice to Proceed7
08/19/2026X01059821-S5Open ↗
08/13/2026X01059821-S5Open ↗
08/13/2026X01059821-P3Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWOER: Notice of Satisfaction4
08/19/2026X01059821-S5Open ↗
08/13/2026X01059821-S1Open ↗
08/13/2026X01059821-I1Open ↗
Showing 3 of 4 on file for this type
▸Other Documents3
▸DOB NOWProperty Ownership Certification3
08/19/2026X01059821-I1Open ↗
08/19/2026X01059821-P5Open ↗
08/19/2026X01059821-P3Open ↗