← Back
Two family converted from one family
359 DECATUR STREET
BROOKLYN · BIN 3047169
💬 Discuss this project
1880Year Built
2Stories
B3Building Class
R6BZoning
2,336 sfGross Floor Area
2Units
1 Open Violation ▸FDNY Report ↗
Two family converted from one family · 1,700 sf lot · 1.37 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 31p · 1 filing · 20 docs
Floor 21p · 2 filings · 20 docs
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
GENESIS NYC CONSTRUCTION303/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/14/2018$1.5M—— → —$642/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ELLEN MARTIN ARCHITECT PC805/28/2025
ALNOUR CONSULTING208/17/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ENKAY DESIGN CONSULTING2003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
WATSON'S PLBG, HTG, & BDGPlumbing1107/08/2026
WATSONS PLBG HTG BDGGeneral Contractor203/22/2026
JEONG YUNGElectrical103/21/2026
GENESIS NYC CONSTRUCTIONGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ALNOUR CONSULTING ENGINEE607601/30/2025
Building Lifecycle
All (27)Filed (10)Permit Issued (3)Signed Off (4)Violation (6)Inspection (4)
09/05/2025
Signed off — Alteration
FOUNDATION SCOPE OF WORK IN-CONUNCTION WITH REAR HORIZONTAL ENLARGEMENT OF EXISTING RESIDENCE.
B00508342-I1
07/25/2025
Signed off — Alteration
PLUMBING SCOPE OF WORK IN-CONJUNCTION WITH GENERAL CONSTRUCTION APPLICATION.
B00431574-I1
05/28/2025
Filed — Alteration
PLUMBING SCOPE OF WORK IN-CONJUNCTION WITH GENERAL CONSTRUCTION APPLICATION.
B00431574-P4
02/12/2025
Signed off — Alteration
B00490713-I1
01/30/2025
Filed — Alteration
PLUMBING SCOPE OF WORK IN-CONJUNCTION WITH GENERAL CONSTRUCTION APPLICATION.
B00431574-P3
01/30/2025
Filed — Alteration
B00490713-P3
08/27/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/26/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
08/15/2024
Permit issued — Plumbing
B00431574-I1-PL
05/23/2024
Signed off — Alteration
STRUCTURAL SCOPE OF WORK IN-CONUNCTION WITH REAR HORIZONTAL ENLARGEMENT OF EXISTING RESIDENCE.
B00508340-I1
05/01/2024
Filed — Alteration
B00490713-P2
04/29/2024
Filed — Alteration
PLUMBING SCOPE OF WORK IN-CONJUNCTION WITH GENERAL CONSTRUCTION APPLICATION.
B00431574-P1
04/27/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/27/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/24/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/24/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
01/28/2022
Violation issued (ECB, closed)
Construction
01/28/2022
Violation issued (ECB, closed)
Construction
01/28/2022
Violation issued (ECB, closed)
Construction
12/08/2021
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/04/2021
Permit issued — Plumbing
B00431574-I1-PL
10/28/2021
Permit issued — General Construction
B00490713-I1-GC
09/18/2021
Filed — Alteration
B00490713-P1
08/20/2021
Filed — Alteration
PLUMBING SCOPE OF WORK IN-CONJUNCTION WITH GENERAL CONSTRUCTION APPLICATION.
B00431574-I1
08/17/2021
Filed — Alteration
FOUNDATION SCOPE OF WORK IN-CONUNCTION WITH REAR HORIZONTAL ENLARGEMENT OF EXISTING RESIDENCE.
B00508342-I1
08/17/2021
Filed — Alteration
STRUCTURAL SCOPE OF WORK IN-CONUNCTION WITH REAR HORIZONTAL ENLARGEMENT OF EXISTING RESIDENCE.
B00508340-I1
06/01/2021
Filed — Alteration
B00490713-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offWATSON'S PLBG, HTG, & BDG08/15/2024
DOB NOWPlumbingSigned-offWATSON'S PLBG, HTG, & BDG11/04/2021
DOB NOWGeneral ConstructionSigned-offGENESIS NYC CONSTRUCTION10/28/2021
1 project · most recent 11/03/2021
General Wiring
FiledStatusContractorScope
11/03/2021Permit IssuedINTELOGIC ELECTRIC, INC.General Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
08/27/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/26/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
02/24/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/24/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
01/31/2025FinalELLEN MARTINprogress
01/31/2025Structural Stability – Alterations of existing buildingsNouredine Benabdelhakspecial
03/16/2023Fire-Resistant Penetrations and JointsNouredine Benabdelhakspecial
09/16/2021Final—progress
09/16/2021Fire-Resistant Penetrations and Joints—special
09/16/2021Structural Stability – Alterations of existing buildings—special
06/07/2021Structural Stability – Alterations of existing buildingsNouredine Benabdelhakspecial
04/22/2021Footing and FoundationNouredine Benabdelhakprogress
04/22/2021Concrete - Cast-In-PlaceNouredine Benabdelhakspecial
04/22/2021Subgrade InspectionsNouredine Benabdelhakspecial
04/22/2021Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
04/22/2021FinalNouredine Benabdelhakprogress
▾Documents — 65 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch6
09/01/2026B00490713-P3Request digital key ↗
09/01/2026B00490713-P1Request digital key ↗
09/01/2026B00490713-P2Request digital key ↗
Showing 3 of 6 on file for this type
▸DOB NOWPlans/Sketch - Plumbing4
09/01/2026B00431574-I1Request digital key ↗
09/01/2026B00431574-P4Request digital key ↗
09/01/2026B00431574-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits5
▸DOB NOWLPC Approval/Permit5
08/13/2026B00431574-P1Open ↗
08/13/2026B00431574-P4Open ↗
08/13/2026B00508340-I1Open ↗
Showing 3 of 5 on file for this type
▸Zoning, Tax Lot & Property Records8
▸DOB NOWZoning Exhibit form (1-5)4
08/13/2026B00490713-I1Open ↗
08/13/2026B00490713-P3Open ↗
08/13/2026B00490713-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram4
08/13/2026B00490713-P3Open ↗
08/13/2026B00490713-P1Open ↗
08/13/2026B00490713-P2Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications19
▸DOB NOWDPL-1: Design Professional Seal & Signature10
09/01/2026B00431574-I1Open ↗
09/01/2026B00431574-P4Open ↗
09/01/2026B00431574-P3Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
08/25/2026B00508342-I1Open ↗
08/25/2026B00508342-I1Open ↗
08/25/2026B00508342-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
08/25/2026B00508342-I1Open ↗
08/25/2026B00508342-I1Open ↗
08/23/2026B00490713-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form4
09/01/2026B00431574-I1Open ↗
09/01/2026B00490713-I1Open ↗
08/13/2026B00508340-I1Open ↗
Showing 3 of 4 on file for this type
▸Inspections & Test Reports3
▸DOB NOWSOIL REPORT1
08/13/2026B00508342-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026B00508342-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026B00508342-I1Open ↗
▸Cost, Insurance & Ownership2
▸DOB NOWCertification by Insurance Broker or Agency1
08/13/2026B00490713-I1Open ↗
▸DOB NOWCertificate of Insurance1
08/13/2026B00490713-I1Open ↗
▸Other Documents14
▸DOB NOWPlot Diagram5
08/13/2026B00490713-P1Open ↗
08/13/2026B00490713-P2Open ↗
08/13/2026B00490713-P3Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
08/13/2026B00490713-P3Open ↗
08/13/2026B00490713-P1Open ↗
08/13/2026B00490713-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSite Survey: Initial3
08/13/2026B00490713-I1Open ↗
08/13/2026B00490713-P2Open ↗
08/13/2026B00490713-P3Open ↗
▸DOB NOWPARTIAL DEMO: 10-DAY Notice1
08/13/2026B00508340-I1Open ↗
▸DOB NOWAdditional Insured Authorizations1
08/13/2026B00490713-I1Open ↗