← Back
Two stories - detached, small or mid-size
36-50 CORPORAL KENNEDY ST
QUEENS · BIN 4488196
💬 Discuss this project
1920Year Built
2.5Stories
A1Building Class
R2AZoning
1,975 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 4,000 sf lot · 0.49 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RUGGIERO AND ASSOCIATES LTD406/17/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
QUEDAN CONSTRUCTION SERVICESGeneral Contractor404/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
RUGGIERO AND ASSOCITES LT4896103/01/2025
Building Lifecycle
All (15)Filed (4)Permit Issued (3)Signed Off (3)Inspection (1)Objection (2)Special Inspection (2)
08/14/2026
Signed off — Alteration
INSTALL 100 LINEAR FEET OF CONSTRUCTION FENCE AROUND EXISTING GARAGE AS PER PLANS.
Q01182725-S2
06/17/2026
Filed — Alteration
INSTALL 100 LINEAR FEET OF CONSTRUCTION FENCE AROUND EXISTING GARAGE AS PER PLANS.
Q01182725-P1
11/18/2025
Inspection — Fail-Final Curb Cut Non-Directive 14
Fail
View inspection ↗
10/24/2025
Signed off — Alteration
INSTALL 100 LINEAR FEET OF CONSTRUCTION FENCE AROUND EXISTING GARAGE AS PER PLANS.
Q01182725-I1
10/24/2025
Signed off — Alteration
INSTALL 100 LINEAR FEET OF CONSTRUCTION FENCE AROUND EXISTING GARAGE AS PER PLANS.
Q01182725-S1
09/19/2025
Permit issued — General Construction
Q01182725-I1-GC
09/19/2025
Permit issued — Construction Fence
Q01182725-S1-FN
09/19/2025
Permit issued — Curb Cut
Q01182725-S2-CC
09/10/2025
Filed — Alteration
INSTALL 100 LINEAR FEET OF CONSTRUCTION FENCE AROUND EXISTING GARAGE AS PER PLANS.
Q01182725-S2
08/01/2025
Filed — Alteration
INSTALL 100 LINEAR FEET OF CONSTRUCTION FENCE AROUND EXISTING GARAGE AS PER PLANS.
Q01182725-S1
06/24/2025
Objection resolved — Addressed
03/14/2025
Objection raised — Scope
03/01/2025
Filed — Alteration
INSTALL 100 LINEAR FEET OF CONSTRUCTION FENCE AROUND EXISTING GARAGE AS PER PLANS.
Q01182725-I1
02/28/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
SANDOLO RUGGIERO
02/18/2025
Special inspection requirement — Final
SANDOLO RUGGIERO
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offQUEDAN CONSTRUCTION SERVI09/19/2025
DOB NOWConstruction FenceSigned-offQUEDAN CONSTRUCTION SERVI09/19/2025
DOB NOWCurb CutSigned-offQUEDAN CONSTRUCTION SERVI09/19/2025
1 project · most recent 06/17/2026
Fence
FiledStatusContractorScope
06/17/2026Signed-offQUEDAN CONSTRUCTION SERVIFence
1 project · most recent 06/17/2026
Construction Fence
FiledStatusContractorScope
06/17/2026Signed-offQUEDAN CONSTRUCTION SERVIConstruction Fence
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
11/18/2025Fail-Final Curb Cut Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
02/28/2025Structural Stability – Alterations of existing buildingsSANDOLO RUGGIEROspecial
02/18/2025FinalSANDOLO RUGGIEROprogress
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/19/2026Q01182725-S2Request digital key ↗
08/19/2026Q01182725-I1Request digital key ↗
08/19/2026Q01182725-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/19/2026Q01182725-S2Open ↗
08/19/2026Q01182725-S1Open ↗
08/19/2026Q01182725-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature1
09/05/2026Q01182725-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/05/2026Q01182725-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/19/2026Q01182725-I1Open ↗