← Back
Elevator apt, semi-fireproof without stores
36 CLARK STREET
BROOKLYN · BIN 3001798
💬 Discuss this project
1908Year Built
6Stories
D1Building Class
R6Zoning
24,570 sfGross Floor Area
29Units
Rent Stabilized6 Open Violations ▸
Elevator apt, semi-fireproof without stores · Owner of record: 36170 RLTY LTD · 4,522 sf lot · 5.43 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Roof1p · 1 filing · 5 docs
Floor 31p · 1 filing · 8 docs
Floor 2
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
36170 REALTY4207/08/2026
OWNER OF 36 CLARK ST103/22/2026
T-MOBILE103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CLIP ARCHITECTS210/09/2025
GREYBAR ARCHITECTURE PLLC401/23/2024
KM CONSULTING ENGINEERS, INC.101/16/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MODERN BUILDING CONSULTANT203/21/2026
GC1 EXPEDITING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ELITE PROFESSIONAL CONSTRGeneral Contractor303/21/2026
AMC PLBG, HTG & CLNG, INCPlumbing207/08/2026
FERRARO, STEVENElectrical103/21/2026
REEDY, GWENDOLYNElectrical103/21/2026
TAKOS, VASILIOS BILLYElectrical103/21/2026
ELITE PROFESSIONAL CONST*General Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GREAT WALL CONSULTANT P.E5633210/09/2025
O'ROURKE ENGINEERING, LLC5873401/23/2024
KM CONSULTING NY, INC.5305101/16/2023
Building Lifecycle
All (88)Filed (7)Permit Issued (4)Signed Off (3)Violation (28)Inspection (4)Objection (18)Special Inspection (24)
03/03/2026
Signed off — Alteration
Propose interior renovation at partial 2nd floor unit 2D of existing residential building with partition work and finish work as per plan. No change in use, egress, or occupancy.
B01241857-I1
11/05/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
10/14/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Xiong Wei Wu
10/14/2025
Special inspection requirement — Lighting in dwelling units
Jaeyoung Jang
10/14/2025
Special inspection requirement — Interior lighting power
Jaeyoung Jang
10/14/2025
Special inspection requirement — Energy Code Compliance Inspections
Jaeyoung Jang
10/14/2025
Special inspection requirement — Fire-Resistance Rated Construction
Jaeyoung Jang
10/14/2025
Special inspection requirement — Tenant Protection Plan Compliance
Xiong Wei Wu
10/09/2025
Filed — Alteration
Propose interior renovation at partial 2nd floor unit 2D of existing residential building with partition work and finish work as per plan. No change in use, egress, or occupancy.
B01241857-P1
09/18/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Xiong Wei Wu
09/18/2025
Special inspection requirement — Tenant Protection Plan Compliance
Xiong Wei Wu
09/18/2025
Special inspection requirement — Energy Code Compliance Inspections
Jaeyoung Jang
09/18/2025
Special inspection requirement — Fire-Resistance Rated Construction
Jaeyoung Jang
09/18/2025
Special inspection requirement — Lighting in dwelling units
Jaeyoung Jang
09/18/2025
Special inspection requirement — Interior lighting power
Jaeyoung Jang
07/02/2025
Permit issued — General Construction
B01241857-I1-GC
06/23/2025
Filed — Alteration
Propose interior renovation at partial 2nd floor unit 2D of existing residential building with partition work and finish work as per plan. No change in use, egress, or occupancy.
B01241857-I1
04/09/2024
Violation issued (HPD, closed)
A
02/22/2024
Signed off — Alteration
INTERIOR RENOVATION OF APARTMENT 3A, NO CHANGE IN USE, EGRESS OR OCCUPANCY
B00907939-I1
02/22/2024
Signed off — Alteration
INTERIOR RENOVATION OF APARTMENT #3A. NEW BATHROOM AND REPLACEMENT OF EXISTING KITCHEN AND BATHROOM PLUMBING FIXTURES.
B00907964-I1
02/06/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
02/06/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/24/2024
Special inspection requirement — Interior lighting power
Nicholas Wilder
01/24/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
BRIAN O'ROURKE
01/24/2024
Special inspection requirement — Fire-Resistance Rated Construction
BRIAN O'ROURKE
01/24/2024
Special inspection requirement — Final
Nicholas Wilder
01/24/2024
Special inspection requirement — Lighting in dwelling units
Nicholas Wilder
01/24/2024
Special inspection requirement — Lighting controls
Nicholas Wilder
01/23/2024
Filed — Alteration
INTERIOR RENOVATION OF APARTMENT 3A, NO CHANGE IN USE, EGRESS OR OCCUPANCY
B00907939-P1
01/23/2024
Filed — Alteration
INTERIOR RENOVATION OF APARTMENT #3A. NEW BATHROOM AND REPLACEMENT OF EXISTING KITCHEN AND BATHROOM PLUMBING FIXTURES.
B00907964-P1
01/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
BRIAN O'ROURKE
01/18/2024
Special inspection requirement — Lighting in dwelling units
Nicholas Wilder
01/18/2024
Special inspection requirement — Lighting controls
Nicholas Wilder
01/18/2024
Special inspection requirement — Interior lighting power
Nicholas Wilder
01/18/2024
Special inspection requirement — Fire-Resistance Rated Construction
BRIAN O'ROURKE
01/18/2024
Special inspection requirement — Final
Nicholas Wilder
01/04/2024
Permit issued — Plumbing
B00907964-I1-PL
11/17/2023
Violation issued (HPD, closed)
I
11/17/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/19/2023
Permit issued — General Construction
B00907939-I1-GC
10/16/2023
Permit issued — Plumbing
B00907964-I1-PL
09/06/2023
Objection resolved — Addressed
08/24/2023
Objection raised — Scope
08/24/2023
Objection resolved — Addressed
08/21/2023
Objection resolved — Addressed
08/21/2023
Objection resolved — Addressed
08/21/2023
Objection resolved — Addressed
08/18/2023
Objection resolved — Addressed
08/18/2023
Objection resolved — Addressed
08/18/2023
Objection resolved — Addressed
08/18/2023
Objection resolved — Addressed
08/08/2023
Objection raised — Other
08/08/2023
Objection raised — Scope
08/08/2023
Objection raised — Fire_Protection
08/08/2023
Objection raised — Admin
08/08/2023
Objection raised — Fire_Protection
08/08/2023
Objection raised — Scope
08/08/2023
Objection raised — Inspections
08/08/2023
Objection raised — Inspections
08/03/2023
Filed — Alteration
INTERIOR RENOVATION OF APARTMENT 3A, NO CHANGE IN USE, EGRESS OR OCCUPANCY
B00907939-I1
Latest 60 of 88 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offELITE PROFESSIONAL CONST*07/02/2025
DOB NOWPlumbingSigned-offAMC PLBG, HTG & CLNG, INC01/04/2024
DOB NOWGeneral ConstructionSigned-offELITE PROFESSIONAL CONSTR10/19/2023
DOB NOWPlumbingSigned-offAMC PLBG, HTG & CLNG, INC10/16/2023
BISOTISSUEDJAGIELLO CONSTRUCTION COR10/02/2014
BISOTISSUEDSKYLINE STEEL FABRICATORS &08/09/2012
BISOTISSUEDTELCOM ENGINEERING GP INC05/09/2007
BISBLISSUEDCALRAY GAS HT CORP09/07/2006
BISPLISSUEDADRIATIC PLBG & HTG CORP01/28/2002
BISOTISSUED36170 REALTY LTD01/28/2002
BISPLISSUEDLIQUID PLBG & HTNG SCS IN08/31/2000
BISOTISSUEDW & A CONSTRUCTION08/01/2000
BISBLISSUEDCALRAY GAS HEAT CORP02/16/2000
BISPLISSUEDCALRAY GAS HEAT CORP02/16/2000
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
11/05/2025Pass-Final General Construction Non-Directive 14PassView ↗
02/06/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/06/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/17/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 24
DateRequirementInspectorRole
10/14/2025Fire-Resistant Penetrations and JointsXiong Wei Wuspecial
10/14/2025Lighting in dwelling unitsJaeyoung Jangenergy_progress
10/14/2025Interior lighting powerJaeyoung Jangenergy_progress
10/14/2025Energy Code Compliance InspectionsJaeyoung Jangprogress
10/14/2025Fire-Resistance Rated ConstructionJaeyoung Jangprogress
10/14/2025Tenant Protection Plan ComplianceXiong Wei Wuspecial
09/18/2025Fire-Resistant Penetrations and JointsXiong Wei Wuspecial
09/18/2025Tenant Protection Plan ComplianceXiong Wei Wuspecial
09/18/2025Energy Code Compliance InspectionsJaeyoung Jangprogress
09/18/2025Fire-Resistance Rated ConstructionJaeyoung Jangprogress
09/18/2025Lighting in dwelling unitsJaeyoung Jangenergy_progress
09/18/2025Interior lighting powerJaeyoung Jangenergy_progress
01/24/2024Interior lighting powerNicholas Wilderenergy_progress
01/24/2024Fire-Resistant Penetrations and JointsBRIAN O'ROURKEspecial
01/24/2024Fire-Resistance Rated ConstructionBRIAN O'ROURKEprogress
01/24/2024FinalNicholas Wilderprogress
01/24/2024Lighting in dwelling unitsNicholas Wilderenergy_progress
01/24/2024Lighting controlsNicholas Wilderenergy_progress
01/18/2024Fire-Resistant Penetrations and JointsBRIAN O'ROURKEspecial
01/18/2024Lighting in dwelling unitsNicholas Wilderenergy_progress
01/18/2024Lighting controlsNicholas Wilderenergy_progress
01/18/2024Interior lighting powerNicholas Wilderenergy_progress
01/18/2024Fire-Resistance Rated ConstructionBRIAN O'ROURKEprogress
01/18/2024FinalNicholas Wilderprogress
▾Documents — 86 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/27/2026B08049600-I1Request digital key ↗
08/27/2026B00907939-P1Request digital key ↗
08/27/2026B00907939-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits14
▸DOB NOWLPC Approval/Permit7
08/13/2026B01241857-I1Open ↗
08/13/2026B08049600-I1Open ↗
08/13/2026B00907939-I1Open ↗
Showing 3 of 7 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION5
12/10/2018321123752Open ↗
05/14/2015321123752Open ↗
06/23/2014320825149Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION2
10/06/2014320825149Open ↗
08/10/2012320356137Open ↗
▸Seals & Professional Certifications33
▸DOB NOWProgress Inspector Seal & Signature14
08/31/2026B00907939-P1Open ↗
08/31/2026B00907939-P1Open ↗
08/31/2026B00907939-P1Open ↗
Showing 3 of 14 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION8
08/02/2017320356137Open ↗
05/14/2015321123752Open ↗
06/23/2014320825149Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/27/2026B08049600-I1Open ↗
08/27/2026B00907939-P1Open ↗
08/27/2026B00907939-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/31/2026B00907939-P1Open ↗
08/27/2026B00907939-I1Open ↗
08/25/2026B01241857-I1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos12
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/27/2026B08049600-I1Open ↗
08/27/2026B08049600-I1Open ↗
08/27/2026B00907939-I1Open ↗
Showing 3 of 8 on file for this type
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)2
06/23/2014320825149Open ↗
05/22/2014320825149Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
06/23/2014320825149Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
09/16/2011320356137Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
05/14/2015321123752Open ↗
06/23/2014320825149Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
08/02/2017320356137Open ↗
▸BISTR8: Energy Code Progress Inspections1
05/22/2014320825149Open ↗
▸Approvals, Objections & Sign-offs6
▸BISADMINISTRATIVE OBJECTIONS3
05/14/2015321123752Open ↗
05/22/2014320825149Open ↗
09/16/2011320356137Open ↗
▸BISLANDMARKS APPROVAL1
05/01/2012320356137Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
08/02/2017320356137Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
08/02/2017320356137Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT5
08/02/2017320356137Open ↗
05/14/2015321123752Open ↗
06/23/2014320825149Open ↗
Showing 3 of 5 on file for this type
▸Filing & Intake Forms5
▸BISEFILING COVER SHEET2
05/14/2015321123752Open ↗
06/23/2014320825149Open ↗
▸BISADDITIONAL INFORMATION1
08/02/2017320356137Open ↗
▸BISBOROUGH INTAKE FORM1
12/10/2018321123752Open ↗
▸BISeFiling Job Application Cover Sheet1
05/22/2014320825149Open ↗