← Back
Primarily 4 family with 1 store or office
36 DITMARS STREET
BROOKLYN · BIN 3072680
💬 Discuss this project
1931Year Built
3Stories
S4Building Class
R6Zoning
4,125 sfGross Floor Area
5Units
Rent Stabilized39 Open Violations 21 unresolved · 18 paperwork only ▸FDNY Report ↗
Primarily 4 family with 1 store or office · Owner of record: DITMARS EQUITIES LLC · 2,375 sf lot · 1.74 FAR built · Flood zone X
Locations of Work
Plumbing
Cellar1p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
DITMARS EQUITIES LLC403/22/2026
DITMARS HOLDINGS LLC1603/22/2026
DITMAR HODINGS LLC103/22/2026
CHOICE MANAGEMENT503/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BAALBAKI&ASSOCIATES ENGINEERING, PC306/21/2025
BARRY BERG ARCHITECT PLLC101/15/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
B A INSPECTIONS803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HESCOTT, CARDINALElectrical103/21/2026
JESUS CORPORANElectrical103/21/2026
RAMSARRAN, RAMESHElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BAALBAKI&ASSOCIATES ENGIN1858102/13/2025
BZINSPECTION8294101/15/2025
Building Lifecycle
All (117)Filed (4)Violation (60)Objection (36)Special Inspection (17)
07/15/2025
Objection resolved — Addressed
07/14/2025
Objection raised — Scope
07/02/2025
Objection resolved — Addressed
07/01/2025
Objection raised — Cost
06/21/2025
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH JOB # B01169118
B01169118-S1
06/17/2025
Objection raised — Admin
06/17/2025
Objection resolved — Addressed
06/14/2025
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH JOB # B01169118
B01169118-S2
06/14/2025
Special inspection requirement — Tenant Protection Plan Compliance
06/05/2025
Objection resolved — Addressed
05/27/2025
Objection resolved — Addressed
05/23/2025
Objection raised — Cost
05/14/2025
Objection resolved — Addressed
05/14/2025
Objection resolved — Addressed
05/13/2025
Objection resolved — Addressed
05/07/2025
Objection resolved — Addressed
04/29/2025
Objection resolved — Addressed
04/29/2025
Objection resolved — Addressed
04/29/2025
Objection resolved — Addressed
04/29/2025
Objection resolved — Addressed
04/29/2025
Objection resolved — Addressed
04/28/2025
Objection raised — Fire_Protection
04/28/2025
Objection raised — Scope
04/28/2025
Objection raised — Energy
04/28/2025
Objection raised — Fire_Protection
04/28/2025
Objection raised — Zoning
04/28/2025
Objection raised — Fire_Protection
04/28/2025
Objection raised — Fire_Protection
04/17/2025
Objection resolved — Addressed
04/17/2025
Objection resolved — Addressed
04/17/2025
Objection resolved — Addressed
04/11/2025
Objection raised — Scope
04/11/2025
Objection raised — Scope
04/11/2025
Objection raised — Fire_Protection
04/11/2025
Objection raised — Fire_Protection
04/02/2025
Objection resolved — Addressed
04/02/2025
Special inspection requirement — HVAC-R and service water heating system controls
Mohammad Baalbaki
04/02/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Mohammad Baalbaki
04/02/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Mohammad Baalbaki
04/02/2025
Special inspection requirement — HVAC-R and service water heating equipment
Mohammad Baalbaki
04/02/2025
Special inspection requirement — Fenestration areas
Mohammad Baalbaki
04/02/2025
Special inspection requirement — Duct leakage testing, insulation and design
Mohammad Baalbaki
04/02/2025
Special inspection requirement — Interior lighting power
Mohammad Baalbaki
02/25/2025
Objection raised — Zoning
02/25/2025
Objection raised — Energy
02/25/2025
Objection raised — Structural
02/13/2025
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH JOB # B01169118
B01169118-I1
02/11/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Mohammad Baalbaki
02/11/2025
Special inspection requirement — Structural Steel - Details
Mohammad Baalbaki
02/11/2025
Special inspection requirement — Tenant Protection Plan Compliance
Mohammad Baalbaki
02/11/2025
Special inspection requirement — Air barrier - visual inspection
Mohammad Baalbaki
02/11/2025
Special inspection requirement — Fenestration air leakage
Mohammad Baalbaki
01/20/2025
Special inspection requirement — Final
Barry Berg
01/20/2025
Special inspection requirement — Mechanical Systems
Mohammad Baalbaki
01/15/2025
Filed — Alteration
LIMITED TO INTERIOR, NON-BEARING DEMOLISHING. ALL CONSTRUCTION WORK TO BE FILED UNDER A SEPARATE FILING
B01167218-I1
01/15/2025
Special inspection requirement — Tenant Protection Plan Compliance
Barry Berg
01/15/2025
Special inspection requirement — Final
10/29/2019
Violation issued (HPD, closed)
I
05/31/2018
Violation issued (HPD, closed)
B
05/07/2018
Violation issued (HPD, closed)
B
Latest 60 of 117 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISMHISSUEDALL PURPOSE GC LLC07/10/2013
BISOTISSUEDALL PURPOSE GC LLC07/09/2013
1 project · most recent 06/21/2025
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
06/21/2025——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MITSUBISHI - 48K BTU - M-SERIES H2I OUTDOOR, MODEL: MXZ-8C48NAHZ CONDENSER - FOR 2-8 ZONES 36,000 CFM · Vrf Outdoor ×2
Ventilation
Captiveaire RESTAURANT CANOPY HOOD GREASE RATED EXHAUST FAN- HIGH SPEED DIRECT DRIVE CENTRIFUGAL UPBLAST EXHAUST FAN WITH SPEED CONTROL- 24 3/4" BASE, 0.75 HP 115 VOLT SINGLE PHASE MOTOR, 1500-2200 CFM (DU85HFA) 60,000 CFM · Exhaust Fan ×1
1 project · most recent 06/21/2025
Gas Water/Sanitary
FiledStatusContractorScope
06/21/2025——Gas, Water/Sanitary
1 project · most recent 06/21/2025
Steel Wood
FiledStatusContractorScope
06/21/2025——Steel, Wood
1 project · most recent 06/21/2025
Fence
FiledStatusContractorScope
06/21/2025——Fence
▾Special Inspection Requirements (DOB NOW) — 17
DateRequirementInspectorRole
06/14/2025Tenant Protection Plan Compliance—special
04/02/2025HVAC-R and service water heating system controlsMohammad Baalbakienergy_progress
04/02/2025Fenestration and door U-factor and product ratingsMohammad Baalbakienergy_progress
04/02/2025HVAC-R and service water piping design and insulationMohammad Baalbakienergy_progress
04/02/2025HVAC-R and service water heating equipmentMohammad Baalbakienergy_progress
04/02/2025Fenestration areasMohammad Baalbakienergy_progress
04/02/2025Duct leakage testing, insulation and designMohammad Baalbakienergy_progress
04/02/2025Interior lighting powerMohammad Baalbakienergy_progress
02/11/2025Structural Stability – Alterations of existing buildingsMohammad Baalbakispecial
02/11/2025Structural Steel - DetailsMohammad Baalbakispecial
02/11/2025Tenant Protection Plan ComplianceMohammad Baalbakispecial
02/11/2025Air barrier - visual inspectionMohammad Baalbakienergy_progress
02/11/2025Fenestration air leakageMohammad Baalbakienergy_progress
01/20/2025FinalBarry Bergprogress
01/20/2025Mechanical SystemsMohammad Baalbakispecial
01/15/2025Tenant Protection Plan ComplianceBarry Bergspecial
01/15/2025Final—progress
▾Documents — 35 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/23/2026B01167218-I1Request digital key ↗
08/22/2026B01169118-I1Request digital key ↗
08/22/2026B01169118-S2Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
04/25/2013320745636Open ↗
▸BISWORK PERMIT APPLICATION1
07/11/2013320745636Open ↗
▸Seals & Professional Certifications19
▸DOB NOWProgress Inspector Seal & Signature9
08/29/2026B01169118-I1Open ↗
08/29/2026B01169118-I1Open ↗
08/29/2026B01169118-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/23/2026B01167218-I1Open ↗
08/13/2026B01169118-S2Open ↗
08/13/2026B01169118-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/29/2026B01169118-I1Open ↗
08/29/2026B01169118-I1Open ↗
08/29/2026B01169118-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY-CERTIFICATION2
07/11/2013320745636Open ↗
04/25/2013320745636Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
04/25/2013320745636Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/23/2026B01167218-I1Open ↗
08/13/2026B01169118-S1Open ↗
08/13/2026B01169118-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
04/25/2013320745636Open ↗
▸Energy Compliance2
▸BISTR8: Energy Code Progress Inspections1
07/11/2013320745636Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
04/25/2013320745636Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
04/25/2013320745636Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
04/25/2013320745636Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
04/25/2013320745636Open ↗