← Back
Two stories - detached, small or mid-size
36 HOUSMAN AVENUE
STATEN ISLAND · BIN 5026664
💬 Discuss this project
1899Year Built
2Stories
A1Building Class
R3AZoning
1,208 sfGross Floor Area
1Units
1 Open Violation ▸FDNY Report ↗
Two stories - detached, small or mid-size · 4,995 sf lot · 0.24 FAR built · Flood zone X500
Locations of Work
PlumbingGeneral
Cellar2p · 2 filings · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHRIS PONISI, ARCHITECT510/10/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DAWN PONISI503/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GREGORY'S HOME IMPROVEMTGeneral Contractor307/08/2026
KCM PLUMBING & HEATING COPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A TECH ENGINEERING NYC, P6738510/10/2021
Building Lifecycle
All (30)Filed (5)Permit Issued (4)Signed Off (3)Inspection (3)Special Inspection (15)
02/28/2022
Signed off — Alteration
NEW BATHROOM IN CELLAR OF EXISTING ONE FAMILY HOME AS PER PLANS SUBMITTED HEREWITH
S00462259-I1
02/02/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/21/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/17/2022
Permit issued — Plumbing
S00462259-I1-PL
01/11/2022
Signed off — Alteration
APPLICATION FILED FOR INTERIOR PARTITIONS IN CELLAR OF EXISTING ONE FAMILY HOME AS INDICATED ON PLANS SUBMITTED HEREWITH
S00462198-I1
01/11/2022
Signed off — Alteration
S00464874-I1
01/05/2022
Inspection — Pass-Final EQ Non-Directive 14
Pass
View inspection ↗
12/04/2021
Permit issued — Foundation
S00464874-I1-GC-CX
10/13/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
anthony santoro
10/13/2021
Special inspection requirement — Fire-Resistance Rated Construction
anthony santoro
10/13/2021
Special inspection requirement — Energy Code Compliance
anthony santoro
10/13/2021
Special inspection requirement — Air barrier - visual inspection
anthony santoro
10/10/2021
Filed — Alteration
NEW BATHROOM IN CELLAR OF EXISTING ONE FAMILY HOME AS PER PLANS SUBMITTED HEREWITH
S00462259-P1
10/10/2021
Filed — Alteration
APPLICATION FILED FOR INTERIOR PARTITIONS IN CELLAR OF EXISTING ONE FAMILY HOME AS INDICATED ON PLANS SUBMITTED HEREWITH
S00462198-P1
10/10/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
anthony santoro
10/10/2021
Special inspection requirement — Energy Code Compliance
anthony santoro
10/10/2021
Special inspection requirement — Maintenance information
anthony santoro
10/10/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
anthony santoro
10/10/2021
Special inspection requirement — Energy Code Compliance
anthony santoro
10/10/2021
Special inspection requirement — Fire-Resistance Rated Construction
anthony santoro
10/10/2021
Special inspection requirement — Air barrier - visual inspection
anthony santoro
06/23/2021
Permit issued — General Construction
S00462198-I1-GC
03/25/2021
Filed — Alteration
S00464874-I1
03/23/2021
Permit issued — General Construction
S00462198-I1-GC
02/10/2021
Filed — Alteration
NEW BATHROOM IN CELLAR OF EXISTING ONE FAMILY HOME AS PER PLANS SUBMITTED HEREWITH
S00462259-I1
02/08/2021
Filed — Alteration
APPLICATION FILED FOR INTERIOR PARTITIONS IN CELLAR OF EXISTING ONE FAMILY HOME AS INDICATED ON PLANS SUBMITTED HEREWITH
S00462198-I1
02/03/2021
Special inspection requirement — Concrete - Cast-In-Place
anthony santoro
02/03/2021
Special inspection requirement — Subgrade Inspections
anthony santoro
02/03/2021
Special inspection requirement — Final
anthony santoro
02/03/2021
Special inspection requirement — Footing and Foundation
anthony santoro
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offKCM PLUMBING & HEATING CO01/17/2022
DOB NOWFoundationSigned-offGREGORY'S HOME IMPROVEMT12/04/2021
DOB NOWGeneral ConstructionSigned-offGREGORY'S HOME IMPROVEMT06/23/2021
DOB NOWGeneral ConstructionSigned-offGREGORY'S HOME IMPROVEMT03/23/2021
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
02/02/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/21/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/05/2022Pass-Final EQ Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 15
DateRequirementInspectorRole
10/13/2021Fire-Resistant Penetrations and Jointsanthony santorospecial
10/13/2021Fire-Resistance Rated Constructionanthony santoroprogress
10/13/2021Energy Code Complianceanthony santoroprogress
10/13/2021Air barrier - visual inspectionanthony santoroenergy_progress
10/10/2021Fire-Resistant Penetrations and Jointsanthony santorospecial
10/10/2021Energy Code Complianceanthony santoroprogress
10/10/2021Maintenance informationanthony santoroenergy_progress
10/10/2021Fire-Resistant Penetrations and Jointsanthony santorospecial
10/10/2021Energy Code Complianceanthony santoroprogress
10/10/2021Fire-Resistance Rated Constructionanthony santoroprogress
10/10/2021Air barrier - visual inspectionanthony santoroenergy_progress
02/03/2021Concrete - Cast-In-Placeanthony santorospecial
02/03/2021Subgrade Inspectionsanthony santorospecial
02/03/2021Finalanthony santoroprogress
02/03/2021Footing and Foundationanthony santoroprogress
▾Documents — 33 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch - General Construction3
08/25/2026S00464874-I1Request digital key ↗
08/25/2026S00462198-P1Request digital key ↗
08/25/2026S00462198-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing2
08/25/2026S00462259-I1Request digital key ↗
08/15/2026S00462259-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Foundation1
08/25/2026S00464874-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records4
▸DOB NOWRestrictive Declaration/Easement 14
08/25/2026S00462259-I1Open ↗
08/25/2026S00462198-I1Open ↗
08/13/2026S00462259-P1Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications16
▸DOB NOWProgress Inspector Seal & Signature7
09/02/2026S00462198-I1Open ↗
09/02/2026S00462198-I1Open ↗
08/31/2026S00462259-P1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/25/2026S00462259-I1Open ↗
08/25/2026S00462198-I1Open ↗
08/13/2026S00462198-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/02/2026S00462198-I1Open ↗
08/31/2026S00462259-P1Open ↗
08/25/2026S00462198-P1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/25/2026S00462259-I1Open ↗
08/25/2026S00462198-I1Open ↗
08/13/2026S00462198-P1Open ↗
Showing 3 of 5 on file for this type
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026S00462198-I1Open ↗
08/13/2026S00462259-I1Open ↗