RoofUnder Construction2p · 3 filings · 8 docs
ArchitectureCivilElectricalEquipmentFire ProtectionGeneralLandscapeMechanicalPlumbingStructural
Issued Permit Scope
Protection and Mechanical Methods · Supported Scaffold
Suspended scaffold from Building Maintenance Unit (BMU) as per plans filed herewith. This application is filed in conjunction with NB-121190200 .
On file for this project
2 documents
INSTALLATION AND USE OF TEMPORARY SUPPORTED SCAFFOLD AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
On file for this project
4 documents · 2 drawing sheets
INSTALLATION OF A TEMPORARY SCAFFOLD TYPE PROTECTION AS PER PLANS IN CONJUNCTION WITH NB CONSTRUCTION. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION. SCAFFOLD PROTECTION INSTALLED IN ACCORDANCE WITH 2022 NYC BUILDING CODE, CHAPTER 33.
On file for this project
2 documents
Floor 401p · 1 filing · 2 docs
ElectricalPlumbingStructural
Issued Permit Scope
Protection and Mechanical Methods
TEMPORARY WORK PLATFORM AS PER DRAWINGS. WORK PLATFORM SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
On file for this project
2 documents · 1 drawing sheet
Floor 39
Floor 38
Floor 37
Floor 36
Floor 35
Floor 34
Floor 33
Floor 32
Floor 31
Floor 30
Floor 29
Floor 28
Floor 27
Floor 26
Floor 25
Floor 24
Floor 23
Floor 22
Floor 21
Floor 201 filing · 6 docs
ArchitectureCivilElectricalEquipmentFire ProtectionGeneralLandscapeMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Protection and Mechanical Methods
Installation and use of suspended scaffold as per plans filed herein. No change in egress, use, or occupancy.
On file for this project
6 documents
Floor 191 filing · 6 docs
ArchitectureCivilElectricalEquipmentFire ProtectionGeneralLandscapeMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Protection and Mechanical Methods · Supported Scaffold
Installation and use of suspended scaffold as per plans filed herein. No change in egress, use, or occupancy.
On file for this project
6 documents
Floor 181 filing · 6 docs
ArchitectureCivilElectricalEquipmentFire ProtectionGeneralLandscapeMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Protection and Mechanical Methods · Supported Scaffold
Installation and use of suspended scaffold as per plans filed herein. No change in egress, use, or occupancy.
On file for this project
6 documents
Floor 171p · 2 filings · 15 docs
ArchitectureCivilElectricalEquipmentFire ProtectionGeneralLandscapeMechanicalPlumbingStructural
Issued Permit Scope
Boiler Equipment · General Construction · Protection and Mechanical Methods
Installation and use of suspended scaffold as per plans filed herein. No change in egress, use, or occupancy.
On file for this project
6 documents
INSTALLATION OF FIVE (5) NEW BOILERS LOCATED ON THE 17TH FLOOR OF A NEW CONSTRUCTION MIXED USE BUILDING. BOILER WORK TYPE ONLY. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
On file for this project
9 documents · 1 drawing sheet
Floor 161 filing · 6 docs
ArchitectureCivilElectricalEquipmentFire ProtectionGeneralLandscapeMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Protection and Mechanical Methods
Installation and use of suspended scaffold as per plans filed herein. No change in egress, use, or occupancy.
On file for this project
6 documents
Floor 152p · 3 filings · 16 docs
ArchitectureCivilElectricalEquipmentFire ProtectionGeneralLandscapeMechanicalPlumbingStructural
Issued Permit Scope
Boiler Equipment · General Construction · Protection and Mechanical Methods
Installation and use of suspended scaffold as per plans filed herein. No change in egress, use, or occupancy.
On file for this project
6 documents · 1 drawing sheet
TEMPORARY WORK PLATFORM AS PER DRAWINGS. WORK PLATFORM SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
On file for this project
2 documents · 1 drawing sheet
INSTALLATION OF NEW FUEL OIL EMERGENCY GENERATOR LOCATED ON THE 15TH FLOOR OF A NEW CONSTRUCTION MIXED USE BUILDING. MECHANICAL AND FUEL STORAGE WORK TYPES. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
On file for this project
8 documents
Floor 14
Floor 132 filings · 7 docs
ArchitectureCivilElectricalEquipmentFire ProtectionGeneralLandscapeMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Protection and Mechanical Methods
FILING APPLICATION FOR THE INTERIOR RENOVATION OF APARTMENT 16D ON THE 13TH FLOOR. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
On file for this project
5 documents
FILING APPLICATION FOR THE INTERIOR RENOVATION OF APARTMENT 16C ON THE 13TH FLOOR. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
On file for this project
2 documents
Floor 122 filings · 7 docs
ArchitectureCivilElectricalEquipmentFire ProtectionGeneralLandscapeMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Protection and Mechanical Methods
GENERAL CONSTRUCTION SCOPE OF WORK: MINOR PARTITION AND INTERIOR DOOR REMOVAL, NEW PARTITIONS AND DOORS, DROPPED CEILINGS, NEW FINISHES AND CANINETRY PER PLANS FILED. NO CHANGE TO USE OCCUPANCY OR EGRESS (TOTAL APT SF IS 1030 SF, AREA OF WORK IS 75 SF)
On file for this project
2 documents
FILING APPLICATION FOR THE INTERIOR RENOVATION OF APARTMENT 15B ON THE 12TH FLOOR. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
On file for this project
5 documents
Floor 112 filings · 16 docs
ArchitectureCivilElectricalEquipmentFire ProtectionGeneralLandscapeMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Protection and Mechanical Methods
MINOR PARTITION AND CABINET REMOVAL, NEW PARTITIONS AND DOORS, DROPPED CEILINGS, NEW FINISHES AND CABINETRY PER PLANS FILED. NO CHANGE TO USE OCCUPANCY OR EGRESS
On file for this project
14 documents
LIMITED CONSTRUCTION OF NEW CEILINGS AND NEW LIGHTING IN EXISTING APARTMENT 11E. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
On file for this project
2 documents
Floor 101p · 2 filings · 5 docs
ArchitectureCivilElectricalEquipmentFire ProtectionGeneralLandscapeMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Protection and Mechanical Methods
LIMITED CONSTRUCTION OF NEW CEILINGS AND NEW LIGHTING IN EXISTING APARTMENT 11E. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
On file for this project
2 documents · 1 drawing sheet
MINOR INTERIOR RENOVATION TO EXISTING APARTMENT 10D ON THE 10TH OF AN EXISTING RESIDENTIAL BUILDING. ARCHITECTURAL WORK. NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
On file for this project
3 documents
Floor 9
Floor 8
ArchitectureCivilElectricalEquipmentFire ProtectionGeneralLandscapeMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Protection and Mechanical Methods · Supported Scaffold
Floor 72 filings · 9 docs
ArchitectureCivilElectricalEquipmentFire ProtectionGeneralLandscapeMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Plumbing · Protection and Mechanical Methods · Sprinklers · Supported Scaffold
Relocation of a clothes washer and two sprinkler heads. No net increase in no. of sprinkler heads.
On file for this project
4 documents
FILING APPLICATION FOR THE INTERIOR RENOVATION OF APARTMENT 8D ON THE 7TH FLOOR. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
On file for this project
5 documents
Floor 6Under Construction7p · 1 filing · 16 docs
ArchitectureCivilElectricalEquipmentFire ProtectionGeneralLandscapeMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Protection and Mechanical Methods · Sprinklers · Supported Scaffold
Subsequent SP work Unit 7CD.
On file for this project
16 documents · 7 drawing sheets
Floor 51 filing · 5 docs
ArchitectureCivilElectricalEquipmentFire ProtectionGeneralLandscapeMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Protection and Mechanical Methods · Supported Scaffold
TEMPORARY PIPE SCAFFOLD AS PER DRAWINGS. SCAFFOLD SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
On file for this project
5 documents
Floor 41 filing · 5 docs
ArchitectureCivilElectricalEquipmentFire ProtectionGeneralLandscapeMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Protection and Mechanical Methods · Supported Scaffold
TEMPORARY PIPE SCAFFOLD AS PER DRAWINGS. SCAFFOLD SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
On file for this project
5 documents
Floor 31 filing · 5 docs
ArchitectureCivilElectricalEquipmentFire ProtectionGeneralLandscapeMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Protection and Mechanical Methods · Supported Scaffold
TEMPORARY PIPE SCAFFOLD AS PER DRAWINGS. SCAFFOLD SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
On file for this project
5 documents
Floor 22 filings · 7 docs
ArchitectureCivilElectricalEquipmentFire ProtectionGeneralLandscapeMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Protection and Mechanical Methods · Supported Scaffold
FILING APPLICATION FOR THE INTERIOR RENOVATION OF APARTMENT 3D ON THE 2ND FLOOR. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
On file for this project
2 documents
TEMPORARY PIPE SCAFFOLD AS PER DRAWINGS. SCAFFOLD SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
On file for this project
5 documents
Floor 1Under Construction12p · 11 filings · 20 docs
ArchitectureCivilElectricalEquipmentFire ProtectionGeneralLandscapeMechanicalPlumbingStructural
Issued Permit Scope
Construction Fence · General Construction · Mechanical Systems · Plumbing · Protection and Mechanical Methods · Sidewalk Shed · Sprinklers · Supported Scaffold
Removal of existing Sprinkler heads and piping, and Installation of Temporary Core Sprinkler Protection only as defined in Bulletin 2020-012.
On file for this project
36 documents · 6 drawing sheets
Installation of temporary construction fence per plan submitted. Work shall comply with 2014 building codes chapter 33. No change in use, egress and/or occupancy with this application.
On file for this project
2 documents
TEMPORARY SYSTEM SCAFFOLD PLATFORMS AS PER DRAWINGS. SYSTEM SCAFFOLD PLATFORMS SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
On file for this project
2 documents
Latest 3 of 11 filings on this floor.
MezzanineUnder Construction1p · 2 filings · 6 docs
Fire ProtectionMechanical
Issued Permit Scope
Mechanical Systems · Sprinklers
New water source air conditioning units with hot water coils. New economizer/condenser, hot and condensate drain water piping. New HVAC ductwork and distribution. Fire, smoke, motorized, and balancing dampers. No change to use, egress or occupancy.
On file for this project
4 documents · 1 drawing sheet
THIS IS WORK FOR TENANT FIT OUT SPRINKLER SYSTEMS AREAS IN COMPLIANCE WITH NFPA 13 AND THE NYC BUILDING CODE. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
On file for this project
2 documents
CellarUnder Construction4p · 4 filings · 20 docs
ArchitectureFire ProtectionMechanicalPlumbing
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers
Removal of existing Sprinkler heads and piping, and Installation of Temporary Core Sprinkler Protection only as defined in Bulletin 2020-012.
On file for this project
36 documents
New water source air conditioning units with hot water coils. New economizer/condenser, hot and condensate drain water piping. New HVAC ductwork and distribution. Fire, smoke, motorized, and balancing dampers. No change to use, egress or occupancy.
On file for this project
4 documents · 2 drawing sheets
THIS IS WORK FOR TENANT FIT OUT SPRINKLER SYSTEMS AREAS IN COMPLIANCE WITH NFPA 13 AND THE NYC BUILDING CODE. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
On file for this project
2 documents · 1 drawing sheet
Latest 3 of 4 filings on this floor.
Sub-CellarUnder Construction8p · 4 filings · 20 docs
ArchitectureFire ProtectionGeneralMechanicalPlumbing
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers
Removal of existing Sprinkler heads and piping, and Installation of Temporary Core Sprinkler Protection only as defined in Bulletin 2020-012.
On file for this project
36 documents · 5 drawing sheets
New water source air conditioning units with hot water coils. New economizer/condenser, hot and condensate drain water piping. New HVAC ductwork and distribution. Fire, smoke, motorized, and balancing dampers. No change to use, egress or occupancy.
On file for this project
4 documents · 1 drawing sheet
THIS IS WORK FOR TENANT FIT OUT SPRINKLER SYSTEMS AREAS IN COMPLIANCE WITH NFPA 13 AND THE NYC BUILDING CODE. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
On file for this project
2 documents
Latest 3 of 4 filings on this floor.
Site & exteriorUnder Construction8 filings · 20 docs
ArchitectureCivilElectricalEquipmentGeneralLandscapeMechanicalPlumbingStructuralOther
Issued Permit Scope
Protection and Mechanical Methods · Sidewalk Shed · Supported Scaffold
TEMPORARY INSTALLATION AND USE OF SIDEWALK SHED PROTECTION AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
On file for this project
20 documents · 12 drawing sheets
Project M01345432Permit Issued · 01/14/2026
INSTALLATION OF PIPE SCAFFOLDING AS PER PLANS. PIPE SCAFFOLDING SHALL COMPLY WITH CHAPTER # 33 OF THE 2022 CODE, NO CHANGESS IN USE IN EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
On file for this project
4 drawing sheets
TEMPORARY HOIST RUN-BACK STRUCTURE DURING NB CONSTRUCTION, FILED SEPARATELY. HOIST RUN-BACK STRUCTURE SHALL COMPLY WITH CH #33 OF THE NYC BLDG CODE. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION. HOIST & ELEVATOR APPL SUBMITTED SEP
On file for this project
2 documents · 2 drawing sheets
Latest 3 of 8 filings on this floor.
Filed — no permit issued6 filings · 18 docs
ArchitectureElectricalFire ProtectionGeneralMechanicalPlumbingStructuralOther
No filed description on record for this project.
On file for this project
7 documents · 2 drawing sheets
No filed description on record for this project.
On file for this project
2 documents · 5 drawing sheets
No filed description on record for this project.
On file for this project
3 documents · 2 drawing sheets
Latest 3 of 6 filings on this floor.