← Back
Primarily 4 family with 1 store or office
361 STOCKHOLM STREET
BROOKLYN · Bushwick (West) · BIN 3073956
💬 Discuss this project
1931Year Built
3Stories
S4Building Class
R6Zoning
4,875 sfGross Floor Area
5Units
Rent Stabilized6 Open Violations ▸FDNY Report ↗
Primarily 4 family with 1 store or office · Owner of record: STOCKHOLM RESIDENCE LLC · 2,500 sf lot · 1.95 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Floor 316p · 2 filings · 20 docs
Floor 213p · 2 filings · 20 docs
Floor 113p · 2 filings · 20 docs
Cellar15p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
STOCKHOLM RESIDENCE LLC203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/22/2021$1.8M—— → —$375/sf building
09/23/2019$790K—VLVVVL, LLC → LELOV 18 CORPORATION$162/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KNF SERVICES CROP508/05/2022
SYED ENGINEERING, P.C.411/29/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EXPRESS FILING INC1803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PLBG P & H INCPlumbing507/08/2026
Y&M HOME BUILDERS INCGeneral Contractor303/21/2026
BRUCHE MECHANICALGeneral Contractor103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SYED ENGINEERING, P.C.7054708/05/2022
Building Lifecycle
All (90)Filed (9)Permit Issued (3)Signed Off (3)Violation (18)Inspection (4)Objection (30)Special Inspection (23)
05/06/2026
Violation issued (HPD, closed)
A
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/11/2025
Violation issued (HPD, closed)
A
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/06/2022
Signed off — Alteration
INTERIOR GUT RENOVATIONS TO AN EXISTING 3 STORY & CELLAR RESIDENTIAL BUILDING . NO CHANGE IN USE, EGRESS OR OCCUPANCY
B00608344-S1
12/06/2022
Signed off — Alteration
INTERIOR GUT RENOVATIONS TO AN EXISTING 3 STORY & CELLAR RESIDENTIAL BUILDING . NO CHANGE IN USE, EGRESS OR OCCUPANCY
B00608344-I1
12/06/2022
Signed off — Alteration
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC JOB #B00550260-I1
B00550260-S1
11/14/2022
Permit issued — Mechanical Systems
B00550260-S1-MS
11/14/2022
Violation issued (HPD, closed)
I
11/09/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
RAFI HAMID
11/09/2022
Special inspection requirement — Final
AKM RAHMAN
11/09/2022
Special inspection requirement — Lighting controls
RAFI HAMID
11/09/2022
Special inspection requirement — Lighting in dwelling units
RAFI HAMID
10/31/2022
Objection resolved — Addressed
10/31/2022
Objection resolved — Addressed
10/31/2022
Objection resolved — Addressed
08/24/2022
Objection resolved — Addressed
08/19/2022
Objection raised — Zoning
08/19/2022
Objection raised — Admin
08/19/2022
Objection raised — Structural
08/19/2022
Objection raised — Scope
08/05/2022
Filed — Alteration
INTERIOR GUT RENOVATIONS TO AN EXISTING 3 STORY & CELLAR RESIDENTIAL BUILDING . NO CHANGE IN USE, EGRESS OR OCCUPANCY
B00608344-P3
04/28/2022
Objection resolved — Addressed
04/28/2022
Objection resolved — Addressed
04/11/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
RAFI HAMID
04/11/2022
Special inspection requirement — Energy Code Compliance Inspections
RAFI HAMID
04/05/2022
Objection raised — Admin
04/05/2022
Objection resolved — Addressed
04/05/2022
Objection resolved — Addressed
04/05/2022
Objection resolved — Addressed
04/05/2022
Objection resolved — Addressed
03/25/2022
Objection raised — Other
03/24/2022
Objection raised — Admin
03/24/2022
Objection raised — Other
03/21/2022
Filed — Alteration
INTERIOR GUT RENOVATIONS TO AN EXISTING 3 STORY & CELLAR RESIDENTIAL BUILDING . NO CHANGE IN USE, EGRESS OR OCCUPANCY
B00608344-P2
03/15/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
RAFI HAMID
03/15/2022
Special inspection requirement — Energy Code Compliance Inspections
RAFI HAMID
03/02/2022
Violation issued (HPD, closed)
A
02/24/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/14/2022
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
01/14/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/14/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
01/07/2022
Permit issued — Plumbing
B00608344-S1-PL
12/30/2021
Objection raised — Other
12/30/2021
Objection raised — Accessibility
12/23/2021
Filed — Alteration
INTERIOR GUT RENOVATIONS TO AN EXISTING 3 STORY & CELLAR RESIDENTIAL BUILDING . NO CHANGE IN USE, EGRESS OR OCCUPANCY
B00608344-P1
12/23/2021
Special inspection requirement — Lighting controls
RAFI HAMID
12/23/2021
Special inspection requirement — Final
RAFI HAMID
12/23/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
RAFI HAMID
12/23/2021
Special inspection requirement — Lighting in dwelling units
RAFI HAMID
12/01/2021
Special inspection requirement — Fire-Resistance Rated Construction
RAFI HAMID
12/01/2021
Special inspection requirement — Final
RAFI HAMID
11/29/2021
Filed — Alteration
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC JOB #B00550260-I1
B00550260-P1
11/28/2021
Filed — Alteration
INTERIOR GUT RENOVATIONS TO AN EXISTING 3 STORY & CELLAR RESIDENTIAL BUILDING . NO CHANGE IN USE, EGRESS OR OCCUPANCY
B00608344-S1
11/28/2021
Special inspection requirement — Final
RAFI HAMID
11/28/2021
Special inspection requirement — Fire-Resistance Rated Construction
RAFI HAMID
11/18/2021
Permit issued — General Construction
B00608344-I1-GC
Latest 60 of 90 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedY&M HOME BUILDERS INC11/14/2022
DOB NOWPlumbingSigned-offPLBG P & H INC01/07/2022
DOB NOWGeneral ConstructionSigned-offY&M HOME BUILDERS INC11/18/2021
1 project · most recent 11/29/2021
Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
11/29/2021Permit IssuedY&M HOME BUILDERS INCHeating Systems, Ventilation Systems
Heating
Daikin RXTQ36TAVJ9A 49,500 BTU · Vrf Outdoor ×6
Ventilation
Greenheck SP-B110 100 CFM · Exhaust Fan ×24
1 project · most recent 12/27/2021
General Wiring
FiledStatusContractorScope
12/27/2021CompleteACCURATE ELEC'L CORP.General Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
02/24/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/14/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
01/14/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/14/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 23
DateRequirementInspectorRole
11/09/2022Structural Stability – Alterations of existing buildingsRAFI HAMIDspecial
11/09/2022FinalAKM RAHMANprogress
11/09/2022Lighting controlsRAFI HAMIDenergy_progress
11/09/2022Lighting in dwelling unitsRAFI HAMIDenergy_progress
04/11/2022Fire-Resistant Penetrations and JointsRAFI HAMIDspecial
04/11/2022Energy Code Compliance InspectionsRAFI HAMIDprogress
03/15/2022Fire-Resistant Penetrations and JointsRAFI HAMIDspecial
03/15/2022Energy Code Compliance InspectionsRAFI HAMIDprogress
12/23/2021Lighting controlsRAFI HAMIDenergy_progress
12/23/2021FinalRAFI HAMIDprogress
12/23/2021Structural Stability – Alterations of existing buildingsRAFI HAMIDspecial
12/23/2021Lighting in dwelling unitsRAFI HAMIDenergy_progress
12/01/2021Fire-Resistance Rated ConstructionRAFI HAMIDprogress
12/01/2021FinalRAFI HAMIDprogress
11/28/2021FinalRAFI HAMIDprogress
11/28/2021Fire-Resistance Rated ConstructionRAFI HAMIDprogress
07/15/2021Energy Code Compliance InspectionsAKM RAHMANprogress
07/15/2021FinalAKM RAHMANprogress
07/15/2021Heating SystemsRAFI HAMIDspecial
07/15/2021Mechanical SystemsRAFI HAMIDspecial
07/15/2021HVAC-R and service water piping design and insulationAKM RAHMANenergy_progress
07/15/2021HVAC-R and service water heating system controlsAKM RAHMANenergy_progress
07/15/2021HVAC-R and service water heating equipmentAKM RAHMANenergy_progress
▾Documents — 55 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
09/01/2026B00608344-S1Request digital key ↗
08/31/2026B00550260-I1Request digital key ↗
08/31/2026B00550260-S2Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION2
09/10/2021321827056Open ↗
08/24/2018321827056Open ↗
▸Seals & Professional Certifications27
▸DOB NOWProgress Inspector Seal & Signature12
08/30/2026B00550260-S1Open ↗
08/30/2026B00550260-S1Open ↗
08/29/2026B00608344-P2Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
09/01/2026B00608344-P1Open ↗
09/01/2026B00608344-P2Open ↗
09/01/2026B00608344-S1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
08/30/2026B00550260-S1Open ↗
08/29/2026B00608344-P2Open ↗
08/27/2026B00608344-I1Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
08/24/2018321827056Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
08/24/2018321827056Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
09/01/2026B00608344-S1Open ↗
08/31/2026B00550260-S2Open ↗
08/31/2026B00550260-P1Open ↗
Showing 3 of 9 on file for this type
▸Energy Compliance3
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026B00608344-I1Open ↗
08/13/2026B00550260-S1Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
08/24/2018321827056Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
08/24/2018321827056Open ↗
▸Filing & Intake Forms2
▸BISBOROUGH INTAKE FORM1
09/10/2021321827056Open ↗
▸BISEFILING COVER SHEET1
08/24/2018321827056Open ↗
▸Other Documents1
▸DOB NOWProject Specific General Liability (PGL1)1
08/13/2026B00608344-I1Open ↗