← Back
BuildNYC
Condo, residential tower (mixed-use, multi-family elevator) [derived]
Onyx Chelsea Condominium
362 8TH AVENUE · BIN 1087714
💬 Discuss this project
2006Year Built
11Stories
RMBuilding Class
C6-2AZoning
58,194 sfGross Floor Area
54Units
LL97 CoveredRent Stabilized6 Active Violations 4 unresolved · 2 paperwork only 3 likely answered 1 old, status unconfirmed ▸FISP: SWARMP
Condo, residential tower (mixed-use, multi-family elevator) [derived] · Owner of record: The Onyx Chelsea Condominium · 7,665 sf lot · 7.59 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbingFire ProtectionEquipmentGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 1Everytable19p · 7 filings · 20 docs
CellarMidboro Management INC.2p · 1 filing · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
261 West3707/08/2026
Bronfman Fisher Real Estate Holdings2103/21/2026
Onyx Chelsea Condominium803/21/2026
NRP LLC II303/21/2026
Realty203/21/2026
322 Partners203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Office of James Ruderman112/20/2022
Leon Skvirsky PE205/03/2022
Michael G. Fahey Architect203/25/2022
EP Engineering103/24/2022
Green Design109/12/2018
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Haider Engineering, P.E103/21/2026
Building Brothers403/21/2026
BMB Building Consulting603/21/2026
Municipal Building Consultants103/21/2026
Haider Engineering P E103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Billy EnterprisesScaffold507/08/2026
Cattro Consulting GroupGeneral Contractor303/21/2026
Paul SignsSign hanger207/08/2026
Colonial CraftersGeneral Contractor203/21/2026
Accurate MechanicalFire Protection107/08/2026
A.goldnerPlumbing103/22/2026
All City ElectricalElectrical103/21/2026
LCS Plumbing & ConsultingPlumbing107/08/2026
Power Surge ElectricElectrical103/21/2026
WCK ElectricElectrical103/21/2026
Omd ElectricalElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Richmond Testing Lab263112/20/2022
Ryan Special Engineering2018103/24/2022
Building Lifecycle
All (111)Filed (7)Permit Issued (9)Signed Off (6)Facade (FISP) (9)Violation (60)Inspection (4)Special Inspection (16)
04/25/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/25/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/20/2023
Cycle 9 facade report submitted
02/20/2023
Cycle 9 facade report signed — SWARMP
02/13/2023
Cycle 9 facade inspection completed
01/10/2023
Permit issued — Structural
M08048590-I1-ST
12/20/2022
Filed — Alteration
M08048590-I1
12/02/2022
Special inspection requirement — Tenant Protection Plan Compliance
RICHARD LEMANSKY
12/02/2022
Special inspection requirement — Final
RICHARD LEMANSKY
12/02/2022
Special inspection requirement — Structural Steel - Welding
RICHARD LEMANSKY
12/02/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
RICHARD LEMANSKY
12/02/2022
Special inspection requirement — Post-installed Anchors
RICHARD LEMANSKY
12/02/2022
Special inspection requirement — Concrete - Cast-In-Place
RICHARD LEMANSKY
07/11/2022
Signed off — Alteration
INSTALL ILLUMINATED SIGN WITHIN WINDOW ( EVERYTABLE)
M00722240-I1
07/11/2022
Signed off — Alteration
INSTALL ILLUMINATED SIGN WITHIN WINDOW ( EVERYTABLE)
M00722259-I1
06/06/2022
Signed off — Alteration
PROPOSE SPRINKLER WORKS AT 1ST WORK IN CONJUNCTION WITH ARCH. DESIGN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00687659-I1
06/06/2022
Signed off — Alteration
PROPOSE PLUMBING WORK IN CONJUNCTION WITH ARCH. DESIGN. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
M00685300-I1
05/24/2022
Signed off — Alteration
PROPOSE INTERIOR RENOVATIONS AT 1ST FLOOR. WORK INCLUDES MINOR PARTITIONS AND FINISH WORK AS PER PLAN. PL AND SP WORK WILL FILE UNDER SEPARATE APPLICATION. NO CHANGE IN USE, EGRESS, AND OCCUPANCY.
M00676752-I1
05/06/2022
Permit issued — Sign
M00722259-I1-SG
05/06/2022
Permit issued — Sign
M00722240-I1-SG
05/05/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/03/2022
Filed — Alteration
INSTALL ILLUMINATED SIGN WITHIN WINDOW ( EVERYTABLE)
M00722240-I1
05/03/2022
Filed — Alteration
INSTALL ILLUMINATED SIGN WITHIN WINDOW ( EVERYTABLE)
M00722259-I1
04/22/2022
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
04/22/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/20/2022
Special inspection requirement — Final
LEON SKVIRSKY
04/20/2022
Special inspection requirement — Final
LEON SKVIRSKY
04/19/2022
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
04/12/2022
Permit issued — Sprinklers
M00687659-I1-EW-SP
04/08/2022
Permit issued — Plumbing
M00685300-I1-PL
04/06/2022
Permit issued — General Construction
M00676752-I1-GC
03/25/2022
Filed — Alteration
PROPOSE PLUMBING WORK IN CONJUNCTION WITH ARCH. DESIGN. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
M00685300-I1
03/25/2022
Filed — Alteration
PROPOSE INTERIOR RENOVATIONS AT 1ST FLOOR. WORK INCLUDES MINOR PARTITIONS AND FINISH WORK AS PER PLAN. PL AND SP WORK WILL FILE UNDER SEPARATE APPLICATION. NO CHANGE IN USE, EGRESS, AND OCCUPANCY.
M00676752-I1
03/24/2022
Filed — Alteration
PROPOSE SPRINKLER WORKS AT 1ST WORK IN CONJUNCTION WITH ARCH. DESIGN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00687659-I1
03/15/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
William Ryan
03/15/2022
Special inspection requirement — Post-installed Anchors
William Ryan
03/03/2022
Special inspection requirement — Lighting controls
Michael Fahey
03/03/2022
Special inspection requirement — Interior lighting power
Michael Fahey
02/25/2022
Special inspection requirement — Sprinkler Systems
William Ryan
02/22/2022
Special inspection requirement — Energy Code Compliance Inspections
Michael Fahey
02/08/2022
Special inspection requirement — Final
Michael Fahey
12/14/2020
Signed off — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 LBS PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M00076564-I1
07/17/2019
Cycle 8 facade report signed — SWARMP
06/26/2019
Cycle 8 facade report submitted
06/13/2019
Cycle 8 facade inspection completed
02/15/2019
Violation issued (ECB, closed)
Construction
02/15/2019
Violation issued (ECB, closed)
Unknown
02/15/2019
Violation issued (ECB, open)
Unknown
02/15/2019
Violation issued (ECB, open)
Unknown
02/15/2019
Violation issued (ECB, closed)
Construction
02/15/2019
Violation issued (ECB, closed)
Construction
02/15/2019
Violation issued (ECB, closed)
Unknown
02/15/2019
Violation issued (ECB, closed)
Construction
02/15/2019
Violation issued (ECB, closed)
Construction
01/11/2019
Permit issued — Sidewalk Shed
M00076564-I1-SH
10/03/2018
Permit issued — Sidewalk Shed
M00076564-I1-SH
09/13/2018
Permit issued — Sidewalk Shed
M00076564-I1-SH
09/12/2018
Filed — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 LBS PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M00076564-I1
09/05/2018
Special inspection requirement — Final
BRIAN T. O'CONNOR
02/21/2018
Cycle 8 facade report submitted
Latest 60 of 111 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedCattro Consulting Group01/10/2023
DOB NOWSignSigned-offPaul Signs05/06/2022
DOB NOWSignSigned-offPaul Signs05/06/2022
DOB NOWSprinklersSigned-offAccurate Mechanical04/12/2022
DOB NOWPlumbingSigned-offAttention to Detail P&H.I04/08/2022
DOB NOWGeneral ConstructionSigned-offColonial Crafters04/06/2022
DOB NOWSidewalk ShedSigned-offBilly Enterprises01/11/2019
DOB NOWSidewalk ShedSigned-offBilly Enterprises10/03/2018
DOB NOWSidewalk ShedSigned-offBilly Enterprises09/13/2018
BISOTISSUEDExo Industries05/22/2019
BISOTISSUEDExo Industries09/13/2018
BISPLISSUEDSal-Tech Plumbing & Heating09/11/2018
BISOTISSUEDHongtai Construction08/14/2018
BISEQISSUEDBilly Enterprises08/02/2017
BISOTISSUEDFresh Meadow Mechanical04/05/2016
BISMHISSUEDFresh Meadow Mechanical04/05/2016
BISPLISSUEDPeter Plumbing Associates04/01/2015
BISOTISSUEDH.Y.M. Construction03/30/2015
BISOTISSUEDK & K Renovation03/27/2014
BIS—ISSUEDFive Town Neon Sign Co02/28/2014
BIS—ISSUEDFive Town Neon Sign Co02/28/2014
BISPLISSUEDLloyd G Drummond Plumbing & Gen12/17/2013
BISOTISSUEDLet's Do It Right10/31/2013
BISOTISSUEDKaizen NY Contracting08/26/2013
BISOTISSUEDMRMD NY08/08/2013
BISPLISSUEDMiller Plumbing & Heating06/07/2013
BISOTISSUEDParamount Builders Contracting05/09/2013
BISOTISSUEDD.M.A. General Contracting09/30/2010
BISOTISSUEDD.M.A. General Contracting09/02/2009
BISEQISSUEDKriesler Borg Florman Gen Construction04/04/2008
BIS—ISSUEDKriesler Borg Florman Gen Construction04/04/2008
BISSPISSUEDCapitol Fire SPKL Co10/15/2007
BISBLISSUEDM. Farbman & Sons07/26/2007
BISPLISSUEDCardoza Ocrp06/15/2007
BISBLISSUEDKreisler BORG_FLORMAN General04/04/2007
BISMHISSUEDKreisler Borg Florman Gen. Construction04/03/2007
BIS—ISSUEDKriesler Borg Florman Gen Construction04/03/2007
BISOTISSUEDKriesler Borg Florman Gen Construction04/03/2007
BISOTISSUEDKreisler Borg Florman04/03/2007
BISEQRE-ISSUEDKriesler Borg Florman Gen Construction04/03/2007
+ 19 more permits on file
8 projects · most recent 07/26/2023
General Wiring
FiledStatusContractorScope
07/26/2023CompleteAll City ElectricalGeneral Wiring
05/11/2023Permit IssuedOmd Electrical1 meters, 1 new_meters
06/30/2022Permit IssuedEmpire State Electl—
06/30/2022Permit IssuedEmpire State Electl—
03/22/2022CompleteBeacon ElectricGeneral Wiring
09/26/2019CompleteGlendale Electl Contng—
09/06/2018CompleteWCK Electric—
02/26/2018Permit IssuedE & M Electrical NYGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
05/05/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/22/2022Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
04/22/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/19/2022Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
12/02/2022Tenant Protection Plan ComplianceRICHARD LEMANSKYspecial
12/02/2022FinalRICHARD LEMANSKYprogress
12/02/2022Structural Steel - WeldingRICHARD LEMANSKYspecial
12/02/2022Structural Stability – Alterations of existing buildingsRICHARD LEMANSKYspecial
12/02/2022Post-installed AnchorsRICHARD LEMANSKYspecial
12/02/2022Concrete - Cast-In-PlaceRICHARD LEMANSKYspecial
04/20/2022FinalLEON SKVIRSKYprogress
04/20/2022FinalLEON SKVIRSKYprogress
03/15/2022Fire-Resistant Penetrations and JointsWilliam Ryanspecial
03/15/2022Post-installed AnchorsWilliam Ryanspecial
03/03/2022Lighting controlsMichael Faheyenergy_progress
03/03/2022Interior lighting powerMichael Faheyenergy_progress
02/25/2022Sprinkler SystemsWilliam Ryanspecial
02/22/2022Energy Code Compliance InspectionsMichael Faheyprogress
02/08/2022FinalMichael Faheyprogress
09/05/2018FinalBRIAN T. O'CONNORprogress
▾Tenants in the building
TenantSpaceFloorsRenovation projects
EverytableRestaurant / Food ServiceFloor 1
Project M00722240 Alteration · LOC Issued · 05/03/2022
Project M00722259 Alteration · LOC Issued · 05/03/2022
Project M00676752 Alteration · LOC Issued · 03/25/2022
Project M00685300 Alteration · LOC Issued · 03/25/2022
Project M00687659 Alteration · LOC Issued · 03/24/2022
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 224 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
09/06/2026M00076564-I1Request digital key ↗
09/02/2026M00687659-I1Request digital key ↗
09/02/2026M00676752-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits42
▸BISWORK PERMIT APPLICATION22
05/28/2019123529226Open ↗
09/13/2018123529226Open ↗
09/11/2018123521144Open ↗
Showing 3 of 22 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION20
07/16/2019123529226Open ↗
12/13/2018123521144Open ↗
11/30/2018123521144Open ↗
Showing 3 of 20 on file for this type
▸Zoning, Tax Lot & Property Records1
▸BISZONING EXHIBIT I- CERTIFICATION1
09/14/2009120104788Open ↗
▸Seals & Professional Certifications63
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION27
12/26/2018123521144Open ↗
08/01/2018123529226Open ↗
07/09/2018123521144Open ↗
Showing 3 of 27 on file for this type
▸DOB NOWProgress Inspector Seal & Signature8
09/02/2026M00076564-I1Open ↗
08/24/2026M08048590-I1Open ↗
08/23/2026M00676752-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
09/06/2026M00076564-I1Open ↗
09/02/2026M00687659-I1Open ↗
09/02/2026M00676752-I1Open ↗
Showing 3 of 7 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST6
07/09/2018123521144Open ↗
03/03/2014121907847Open ↗
03/03/2014121907856Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT5
07/09/2018123521144Open ↗
08/01/2017140669738Open ↗
03/03/2014121907847Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
08/25/2026M00687659-I1Open ↗
08/25/2026M00687659-I1Open ↗
08/25/2026M00687659-I1Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM3
08/13/2013121744461Open ↗
05/01/2013121602202Open ↗
05/01/2013121602202Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
08/01/2017140669738Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
08/01/2017140669738Open ↗
▸Trade Schedules & Equipment11
▸BISSELF-CERT PLUMBING NOTICE6
07/16/2015122251080Open ↗
03/27/2014121806830Open ↗
02/12/2014121806830Open ↗
Showing 3 of 6 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE3
07/09/2018123521144Open ↗
09/21/2015122526052Open ↗
02/03/2015122251080Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT1
03/07/2014121806830Open ↗
▸BISSCHEDULE B - PLUMBING1
05/01/2013121602202Open ↗
▸Safety & Tenant Protection6
▸BISTenant Protection Plan and Notes5
08/01/2018123529226Open ↗
07/09/2018123521144Open ↗
07/22/2016122838885Open ↗
Showing 3 of 5 on file for this type
▸BISST-1 Street Tree Checklist1
07/14/2009120104788Open ↗
▸Environmental & Asbestos9
▸BISASBESTOS-CERTIFICATION (DEP ACP5)4
05/01/2013121602202Open ↗
05/01/2013121602202Open ↗
09/21/2015122526052Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
09/02/2026M00687659-I1Open ↗
09/02/2026M00676752-I1Open ↗
09/02/2026M00685300-I1Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
07/14/2009120104788Open ↗
▸BISASBESTOS: EXEMPTION (ASB4)1
01/04/2016122614965Open ↗
▸Energy Compliance22
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS16
12/26/2018123521144Open ↗
08/01/2018123529226Open ↗
07/09/2018123521144Open ↗
Showing 3 of 16 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS5
12/26/2018123521144Open ↗
02/28/2017122526052Open ↗
10/06/2015122251080Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWEN2: As Built Energy Analysis1
09/02/2026M00676752-I1Open ↗
▸Inspections & Test Reports2
▸BISINSPECTION REPORT - SUPPORTING DOCUMENTATION1
12/26/2018123521144Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
08/01/2017140669738Open ↗
▸Approvals, Objections & Sign-offs11
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST7
12/26/2018123521144Open ↗
02/28/2017122526052Open ↗
10/06/2015122251080Open ↗
Showing 3 of 7 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION2
02/16/2016122526052Open ↗
03/28/2014121806830Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
05/01/2013121602202Open ↗
07/14/2009120104788Open ↗
▸Cost, Insurance & Ownership23
▸BISCOST AFFIDAVIT22
07/29/2019123529226Open ↗
12/26/2018123521144Open ↗
08/01/2018123529226Open ↗
Showing 3 of 22 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT1
04/07/2015122251080Open ↗
▸Filing & Intake Forms25
▸BISEFILING COVER SHEET15
08/01/2018123529226Open ↗
07/09/2018123521144Open ↗
07/22/2016122838885Open ↗
Showing 3 of 15 on file for this type
▸BISADDITIONAL INFORMATION5
12/13/2018123521144Open ↗
02/16/2016122526052Open ↗
08/25/2014121744461Open ↗
Showing 3 of 5 on file for this type
▸BISBOROUGH INTAKE FORM4
07/16/2019123529226Open ↗
12/26/2018123521144Open ↗
11/30/2018123521144Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET1
08/01/2017140669738Open ↗
▸Other Documents2
▸BISSEPTIC - SUPPORTING DOCUMENTATION1
08/01/2017140669738Open ↗
▸DOB NOWBSA Meeting Minutes/BSA Resolution1
09/06/2026M00076564-I1Open ↗