← Back
Two stories - detached, small or mid-size
3624 AVENUE P
BROOKLYN · BIN 3212462
💬 Discuss this project
1925Year Built
1.75Stories
A1Building Class
R3-2Zoning
1,191 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 2,805 sf lot · 0.42 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction9p · 1 filing · 20 docs
Floor 2Under Construction11p · 1 filing · 20 docs
Floor 1Under Construction11p · 1 filing · 20 docs
CellarUnder Construction16p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/12/2021$620K—— → —$521/sf building
09/28/2017$500K—— → —$420/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CL ENGINEERING P.C.306/21/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
METRO DESIGN CONSULTANTS INC603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ALL PRO PLBG & HTG INCPlumbing807/14/2026
CHANDRABALI RAMANANDGeneral Contractor407/11/2026
RAMANAND CHANDRABALIGeneral Contractor203/21/2026
ABE HIMELFARBElectrical103/21/2026
BENJAMIN DREBINElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CL ENGINEERING P.C.6781206/01/2021
Building Lifecycle
All (80)Filed (3)Permit Issued (6)Inspection (15)Objection (30)Special Inspection (26)
07/17/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/14/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
07/13/2026
Permit issued — Plumbing
B00520137-S1-PL
07/10/2026
Permit issued — Mechanical Systems
B00520137-I1-GC-CX
11/17/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/01/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/27/2025
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
07/18/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/09/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/25/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/22/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
09/22/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/22/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
09/20/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
09/20/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/28/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/03/2022
Permit issued — Plumbing
B00520137-S1-PL
07/21/2022
Permit issued — Structural
B00520137-I1-GC-CX
10/15/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/16/2021
Permit issued — Construction Fence
B00520137-S2-FN
07/16/2021
Permit issued — General Construction
B00520137-I1-GC-CX
06/28/2021
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
06/21/2021
Filed — Alteration
FILED HEREWITH PLUMBING WORK TYPES IN CONJUNCTION WITH DOB NOW APPLICATION # B00520137-I1.
B00520137-S2
06/07/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
CHRISTIAN LOZADA
06/03/2021
Objection raised — Structural
06/03/2021
Objection resolved — Addressed
06/03/2021
Objection raised — Structural
06/03/2021
Objection resolved — Addressed
06/03/2021
Objection raised — Structural
06/03/2021
Objection resolved — Addressed
06/03/2021
Objection raised — Structural
06/03/2021
Objection resolved — Addressed
06/03/2021
Objection raised — Scope
06/03/2021
Objection resolved — Addressed
06/03/2021
Objection raised — Scope
06/03/2021
Objection resolved — Addressed
06/03/2021
Objection raised — Admin
06/03/2021
Objection resolved — Addressed
06/03/2021
Objection raised — Structural
06/03/2021
Objection resolved — Addressed
06/03/2021
Objection raised — Scope
06/03/2021
Objection resolved — Addressed
06/03/2021
Objection raised — Structural
06/03/2021
Objection resolved — Addressed
06/02/2021
Objection raised — Scope
06/02/2021
Objection resolved — Addressed
06/02/2021
Objection raised — Scope
06/02/2021
Objection resolved — Addressed
06/02/2021
Objection raised — Mechanical
06/02/2021
Objection resolved — Addressed
06/02/2021
Objection raised — Mechanical
06/02/2021
Objection resolved — Addressed
06/02/2021
Objection raised — Mechanical
06/02/2021
Objection resolved — Addressed
06/01/2021
Filed — Alteration
FILED HEREWITH PLUMBING WORK TYPES IN CONJUNCTION WITH DOB NOW APPLICATION # B00520137-I1.
B00520137-S1
05/28/2021
Special inspection requirement — HVAC-R and service water heating equipment
CHRISTIAN LOZADA
05/28/2021
Special inspection requirement — HVAC-R and service water heating system controls
CHRISTIAN LOZADA
05/28/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
CHRISTIAN LOZADA
05/28/2021
Special inspection requirement — Energy Code Compliance Inspections
CHRISTIAN LOZADA
05/28/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHRISTIAN LOZADA
Latest 60 of 80 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedALL PRO PLBG & HTG INC07/13/2026
DOB NOWMechanical SystemsPermit IssuedCHANDRABALI RAMANAND07/10/2026
DOB NOWPlumbingPermit IssuedALL PRO PLBG & HTG INC11/03/2022
DOB NOWStructuralPermit IssuedCHANDRABALI RAMANAND07/21/2022
DOB NOWConstruction FencePermit IssuedCHANDRABALI RAMANAND07/16/2021
DOB NOWGeneral ConstructionPermit IssuedCHANDRABALI RAMANAND07/16/2021
1 project · most recent 06/21/2021
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
06/21/2021Permit IssuedCHANDRABALI RAMANANDAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Blueridge BHP15L60P 56,500 BTU · Condensing Unit ×1
Heating
Blueridge BHP15L60P 55,000 BTU · Condensing Unit ×1
Ventilation
Hampton Bay 7114-01 50 CFM · Exhaust Fan ×4
Delta Breeze SMT150 150 CFM · Exhaust Fan ×2
1 project · most recent 06/21/2021
Gas Water/Sanitary
FiledStatusContractorScope
06/21/2021Permit IssuedALL PRO PLBG & HTG INCGas, Water/Sanitary
1 project · most recent 04/11/2023
General Wiring
FiledStatusContractorScope
04/11/2023Permit IssuedACCURATE ELEC'L CORP.General Wiring
1 project · most recent 06/21/2021
Wood
FiledStatusContractorScope
06/21/2021Permit IssuedALL PRO PLBG & HTG INCWood
1 project · most recent 06/21/2021
Fence
FiledStatusContractorScope
06/21/2021Permit IssuedALL PRO PLBG & HTG INCFence
▾Field Inspections (DOB CAP) — 15
DateTypeResultReport
07/17/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/14/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
11/17/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/01/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/27/2025Pass-Final PL - UndergroundPassView ↗
07/18/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/09/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/25/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/22/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
09/22/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/22/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
09/20/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
09/20/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/28/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/15/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 26
DateRequirementInspectorRole
06/28/2021Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
06/07/2021Structural Stability – Alterations of existing buildingsCHRISTIAN LOZADAspecial
05/28/2021HVAC-R and service water heating equipmentCHRISTIAN LOZADAenergy_progress
05/28/2021HVAC-R and service water heating system controlsCHRISTIAN LOZADAenergy_progress
05/28/2021HVAC-R and service water piping design and insulationCHRISTIAN LOZADAenergy_progress
05/28/2021Energy Code Compliance InspectionsCHRISTIAN LOZADAprogress
05/28/2021Fire-Resistant Penetrations and JointsCHRISTIAN LOZADAspecial
05/28/2021Maintenance informationCHRISTIAN LOZADAenergy_progress
05/26/2021Concrete - Cast-In-PlaceCHRISTIAN LOZADAspecial
05/11/2021HVAC-R and service water piping design and insulationCHRISTIAN LOZADAenergy_progress
05/11/2021HVAC-R and service water heating equipmentCHRISTIAN LOZADAenergy_progress
05/11/2021Fenestration and door U-factor and product ratingsCHRISTIAN LOZADAenergy_progress
05/11/2021Fenestration air leakageCHRISTIAN LOZADAenergy_progress
05/11/2021HVAC-R and service water heating system controlsCHRISTIAN LOZADAenergy_progress
05/11/2021Maintenance informationCHRISTIAN LOZADAenergy_progress
05/11/2021Interior lighting powerCHRISTIAN LOZADAenergy_progress
05/11/2021Ventilation and air distribution systemCHRISTIAN LOZADAenergy_progress
05/11/2021Fenestration areasCHRISTIAN LOZADAenergy_progress
05/11/2021Mechanical SystemsCHRISTIAN LOZADAspecial
05/11/2021Fire-Resistant Penetrations and JointsCHRISTIAN LOZADAspecial
05/11/2021Heating SystemsCHRISTIAN LOZADAspecial
05/11/2021Subgrade InspectionsCHRISTIAN LOZADAspecial
05/11/2021FinalCHRISTIAN LOZADAprogress
05/11/2021Energy Code Compliance InspectionsCHRISTIAN LOZADAprogress
05/11/2021Fire-Resistance Rated ConstructionCHRISTIAN LOZADAprogress
Latest 25 of 26.
▾Documents — 21 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
09/01/2026B00520137-S2Request digital key ↗
08/15/2026B00520137-S1Request digital key ↗
08/14/2026B00520137-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWRestrictive Declaration/Easement 12
08/13/2026B00520137-I1Open ↗
08/13/2026B00520137-S1Open ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026B00520137-S1Open ↗
09/01/2026B00520137-S1Open ↗
08/26/2026B00520137-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
09/01/2026B00520137-S1Open ↗
09/01/2026B00520137-I1Open ↗
09/01/2026B00520137-S2Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026B00520137-S1Open ↗
08/26/2026B00520137-I1Open ↗
08/26/2026B00520137-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/15/2026B00520137-S1Open ↗
08/14/2026B00520137-I1Open ↗
▸Inspections & Test Reports3
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026B00520137-I1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026B00520137-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026B00520137-I1Open ↗
▸Other Documents1
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026B00520137-I1Open ↗