← Back
Walk-up apt, over six families with stores
363 WEST 57 STREET
MANHATTAN · Hell's Kitchen · BIN 1026047
💬 Discuss this project
1920Year Built
5Stories
C7Building Class
C1-8Zoning
9,290 sfGross Floor Area
18Units
Rent Stabilized11 Open Violations 10 unresolved · 1 paperwork only ▸
Walk-up apt, over six families with stores · Owner of record: 363 ASSOCIATES, · 2,000 sf lot · 4.65 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingEquipmentCivilGeneral
Roof10p · 2 filings · 20 docs
Floor 118p · 2 filings · 20 docs
Site & exterior21p · 4 filings · 20 docs
Filed — no permit issued18p · 1 filing · 10 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
AJ CLARKE REAL ESTATE3707/08/2026
363 ASSOCIATES LLC C O AJ CLARKE203/21/2026
363 ASSOCIATES,103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SOTIR ASSOCIATES1012/26/2024
ASHRAF CORP209/19/2024
DS ENGINEERING SERVICES, PC105/14/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PHOENIX SUTTON STR INCGeneral Contractor507/08/2026
MSN CONSTRUCTION INCGeneral Contractor307/08/2026
SHAM CONSTRUCTION GROUPGeneral Contractor303/21/2026
MAMC CONSULTING REPS LLCGeneral Contractor307/08/2026
MATSIKAS VASILIOSElectrical103/21/2026
MICHAEL BAPTISTEElectrical103/21/2026
OFFER, IElectrical103/21/2026
PENA, SANDYElectrical103/21/2026
QUINTANA, DAVIDElectrical103/21/2026
TAKOS, VASILIOS BILLYElectrical103/21/2026
VASILIOS MATSIKASElectrical103/21/2026
CHETRAM, RISHIRAMElectrical103/21/2026
KATAN P & H INCPlumbing107/08/2026
FERRARO, STEVENElectrical103/21/2026
JIMENEZ LUISElectrical103/21/2026
LUIS JIMENEZElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ENGINEERING CONSULTING SE2050412/26/2024
SOTIR ASSOCIATES7473306/26/2024
ADS SPECIAL INSPECTIONS1270105/14/2024
DS ENGINEERING SERVICES,1608105/14/2024
Building Lifecycle
All (114)Filed (13)Permit Issued (11)Signed Off (3)Violation (25)Objection (32)Special Inspection (30)
06/04/2025
Violation issued (HPD, closed)
A
04/23/2025
Signed off — Alteration
M01049212-I1
03/25/2025
Signed off — Alteration
M01113328-I1
03/25/2025
Signed off — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF 2022 THE NYC BUILDING CODE. LIVE LOAD 300PSF.
M00991423-I1
01/17/2025
Permit issued — Sidewalk Shed
M00991423-I1-SH
01/10/2025
Special inspection requirement — Mechanical Systems
PAUL MARINO
01/10/2025
Special inspection requirement — Tenant Protection Plan Compliance
01/10/2025
Special inspection requirement — Shutoff dampers
PAUL MARINO
01/10/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
PAUL MARINO
01/10/2025
Special inspection requirement — HVAC-R and service water heating system controls
PAUL MARINO
01/10/2025
Special inspection requirement — HVAC-R and service water heating equipment
PAUL MARINO
01/10/2025
Special inspection requirement — Final
Magdy Youssef
01/03/2025
Objection resolved — Addressed
01/02/2025
Objection raised — Other
12/26/2024
Filed — Alteration
MECHANICAL WORK FOR EXISTING 1ST FL COMMERCIAL SPACE, IN CONJUNCTION WITH RENOVATIONS FILED UNDER M01119269-I1, FOR NEW EXHAUST DUCTWORK TO NEW EXHAUST FAN ON THE ROOF, NEW REFRIGERATION COMPRESSORS & NEW HEAT PUMP ON ROOF.
M01119269-P1
12/24/2024
Special inspection requirement — HVAC-R and service water heating system controls
PAUL MARINO
12/24/2024
Special inspection requirement — Final
Magdy Youssef
12/24/2024
Special inspection requirement — Tenant Protection Plan Compliance
12/24/2024
Special inspection requirement — Mechanical Systems
PAUL MARINO
12/24/2024
Special inspection requirement — HVAC-R and service water heating equipment
PAUL MARINO
12/24/2024
Special inspection requirement — Shutoff dampers
PAUL MARINO
12/24/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
PAUL MARINO
12/05/2024
Permit issued — Plumbing
M01119269-S2-PL
11/20/2024
Permit issued — General Construction
M01119269-I1-GC
11/15/2024
Permit issued — General Construction
M00992680-I1-GC
11/07/2024
Objection resolved — Addressed
11/07/2024
Objection resolved — Addressed
11/06/2024
Permit issued — Mechanical Systems
M01119269-S1-MS
11/04/2024
Objection raised — Other
10/28/2024
Objection raised — Accessibility
10/24/2024
Filed — Alteration
MECHANICAL WORK FOR EXISTING 1ST FL COMMERCIAL SPACE, IN CONJUNCTION WITH RENOVATIONS FILED UNDER M01119269-I1, FOR NEW EXHAUST DUCTWORK TO NEW EXHAUST FAN ON THE ROOF, NEW REFRIGERATION COMPRESSORS & NEW HEAT PUMP ON ROOF.
M01119269-I1
10/24/2024
Filed — Alteration
MECHANICAL WORK FOR EXISTING 1ST FL COMMERCIAL SPACE, IN CONJUNCTION WITH RENOVATIONS FILED UNDER M01119269-I1, FOR NEW EXHAUST DUCTWORK TO NEW EXHAUST FAN ON THE ROOF, NEW REFRIGERATION COMPRESSORS & NEW HEAT PUMP ON ROOF.
M01119269-S1
10/24/2024
Filed — Alteration
MECHANICAL WORK FOR EXISTING 1ST FL COMMERCIAL SPACE, IN CONJUNCTION WITH RENOVATIONS FILED UNDER M01119269-I1, FOR NEW EXHAUST DUCTWORK TO NEW EXHAUST FAN ON THE ROOF, NEW REFRIGERATION COMPRESSORS & NEW HEAT PUMP ON ROOF.
M01119269-S2
09/20/2024
Permit issued — Supported Scaffold
M01113328-I1-SF
09/19/2024
Filed — Alteration
M01113328-I1
08/22/2024
Objection resolved — Addressed
08/22/2024
Objection resolved — Addressed
08/21/2024
Permit issued — General Construction
M01049212-I1-GC
08/15/2024
Objection raised — Admin
08/15/2024
Objection raised — Other
08/15/2024
Objection raised — Admin
08/02/2024
Filed — Alteration
INTERIOR RENOVATION TO THE EXISTING 1ST FLOOR COMMERCIAL SPACE TO CREATE A NEW DELI WITH A FULL COMMERCIAL KITCHEN & NEW HOOD. PROPOSED NEW EXHAUST & REFRIGERATION COMPRESSORS.
M00975845-S2
08/02/2024
Special inspection requirement — HVAC-R and service water heating equipment
07/31/2024
Special inspection requirement — Tenant Protection Plan Compliance
07/31/2024
Special inspection requirement — Energy Code Compliance Inspections
07/17/2024
Objection resolved — Addressed
06/28/2024
Permit issued — Suspended Scaffold
M01068655-I1-SC
06/27/2024
Special inspection requirement — Energy Code Compliance Inspections
Hany Demetry
06/27/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Hany Demetry
06/27/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Hany Demetry
06/27/2024
Special inspection requirement — Tenant Protection Plan Compliance
Hany Demetry
06/26/2024
Filed — Alteration
TEMPORARY CONSTRUCTION FENCE TO SECURE 1ST FLOOR COMMERCIAL SPACE DURING CONSTRUCTION ACTIVITIES UNDER APPLICATIONS M00992680, M00975845.
M00992680-P1
06/26/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Hany Demetry
06/26/2024
Special inspection requirement — Energy Code Compliance Inspections
Hany Demetry
06/26/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Hany Demetry
06/26/2024
Special inspection requirement — Tenant Protection Plan Compliance
06/21/2024
Objection resolved — Addressed
06/18/2024
Filed — Alteration
M01068655-I1
06/11/2024
Objection resolved — Addressed
06/11/2024
Objection resolved — Addressed
Latest 60 of 114 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedSigned-offPHOENIX SUTTON STR INC01/17/2025
DOB NOWPlumbingPermit IssuedKATAN P & H INC12/05/2024
DOB NOWGeneral ConstructionPermit IssuedMAMC CONSULTING REPS LLC11/20/2024
DOB NOWGeneral ConstructionPermit IssuedMAMC CONSULTING REPS LLC11/15/2024
DOB NOWMechanical SystemsPermit IssuedMAMC CONSULTING REPS LLC11/06/2024
DOB NOWSupported ScaffoldSigned-offPHOENIX SUTTON STR INC09/20/2024
DOB NOWGeneral ConstructionSigned-offMSN CONSTRUCTION INC08/21/2024
DOB NOWSuspended ScaffoldPermit IssuedMSN CONSTRUCTION INC06/28/2024
DOB NOWGeneral ConstructionSigned-offMSN CONSTRUCTION INC05/29/2024
DOB NOWSidewalk ShedSigned-offPHOENIX SUTTON STR INC01/26/2024
DOB NOWGeneral ConstructionPermit IssuedSHAM CONSTRUCTION GROUP01/26/2024
BISEQISSUEDEVEREST SCAFFOLDING INC04/14/2011
BISOTISSUEDSAMMYS RESTORATION INC06/28/2006
BISEQISSUEDSPRING SCAFFOLDING07/27/1999
BISOTISSUEDS. LEGGERIO CONST. INC.08/19/1998
BISPLISSUEDBRONZE PLUMBING & HEATING08/19/1998
BISFPISSUEDARROW MECH SYS/IDEAL FIRE CONTRO11/19/1991
2 projects · most recent 12/26/2024
Air Conditioning Systems Refrigeration Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
12/26/2024Permit IssuedMAMC CONSULTING REPS LLCAir Conditioning Systems, Refrigeration Systems, Ventilation Systems
Cooling
Daikin RXYQ120XATJA 120,000 BTU · Vrf Outdoor ×1
RXYQ96XATJA 120,000 BTU · Vrf Outdoor ×1
Ventilation
Greenheck BSQ 90-4X-QD 1,012 CFM · Makeup Air ×2
CUBE-200-LMD130GQD 6,806 CFM · Kitchen Exhaust ×2
Refrigeration
Copeland XFAM-045Z-TFC-081; XFAM-050Z-TFC-081; XFAM-030Z-TFC-081 56,000 BTU · Condensing Unit ×3
XFAM-017Z-TFC-081; XFAM-045Z-TFC-081; XFAM-020Z-TFC-081 56,000 BTU · Condensing Unit ×3
08/02/2024——Air Conditioning Systems, Refrigeration Systems, Ventilation Systems
Cooling
Daikin RXYQ120XATJA 120,000 BTU · Vrf Outdoor ×1
Ventilation
Dayton 488V78 3,911 CFM · Exhaust Fan ×1
Greenheck BSQ-240 2,400 CFM · Makeup Air ×1
Refrigeration
Copeland XFAM 030Z TFC 081 56,000 BTU · Refrigeration Unit ×1
XFAM 045Z TFC 081 56,000 BTU · Refrigeration Unit ×1
XFAM 050Z TFC 081 56,000 BTU · Refrigeration Unit ×1
2 projects · most recent 12/26/2024
Water/Sanitary
FiledStatusContractorScope
12/26/2024Permit IssuedKATAN P & H INCWater/Sanitary
08/02/2024——Water/Sanitary
2 projects · most recent 07/15/2024
FiledStatusContractorScope
07/15/2024Permit IssuedWCK ELECTRIC CORP.10 meters, 1 new_meters
01/08/2024CompleteELPO ELECTRICAL CONTG INC—
1 project · most recent 06/26/2024
FiledStatusContractorScope
06/26/2024Permit IssuedMAMC CONSULTING REPS LLC1 scope_items
1 project · most recent 06/26/2024
Fence
FiledStatusContractorScope
06/26/2024Permit IssuedMAMC CONSULTING REPS LLCFence
▾Special Inspection Requirements (DOB NOW) — 30
DateRequirementInspectorRole
01/10/2025Mechanical SystemsPAUL MARINOspecial
01/10/2025Tenant Protection Plan Compliance—special
01/10/2025Shutoff dampersPAUL MARINOenergy_progress
01/10/2025HVAC-R and service water piping design and insulationPAUL MARINOenergy_progress
01/10/2025HVAC-R and service water heating system controlsPAUL MARINOenergy_progress
01/10/2025HVAC-R and service water heating equipmentPAUL MARINOenergy_progress
01/10/2025FinalMagdy Youssefprogress
12/24/2024HVAC-R and service water heating system controlsPAUL MARINOenergy_progress
12/24/2024FinalMagdy Youssefprogress
12/24/2024Tenant Protection Plan Compliance—special
12/24/2024Mechanical SystemsPAUL MARINOspecial
12/24/2024HVAC-R and service water heating equipmentPAUL MARINOenergy_progress
12/24/2024Shutoff dampersPAUL MARINOenergy_progress
12/24/2024HVAC-R and service water piping design and insulationPAUL MARINOenergy_progress
08/02/2024HVAC-R and service water heating equipment—energy_progress
07/31/2024Tenant Protection Plan Compliance—special
07/31/2024Energy Code Compliance Inspections—progress
06/27/2024Energy Code Compliance InspectionsHany Demetryprogress
06/27/2024Fire-Resistant Penetrations and JointsHany Demetryspecial
06/27/2024Structural Stability – Alterations of existing buildingsHany Demetryspecial
06/27/2024Tenant Protection Plan ComplianceHany Demetryspecial
06/26/2024Structural Stability – Alterations of existing buildingsHany Demetryspecial
06/26/2024Energy Code Compliance InspectionsHany Demetryprogress
06/26/2024Fire-Resistant Penetrations and JointsHany Demetryspecial
06/26/2024Tenant Protection Plan Compliance—special
Latest 25 of 30.
▾Documents — 85 on file (BIS + DOB NOW)
▸Plans & Drawings14
▸DOB NOWPlans/Sketch14
08/28/2026M00991423-I1Request digital key ↗
08/27/2026M01049212-I1Request digital key ↗
08/27/2026M00975845-I1Request digital key ↗
Showing 3 of 14 on file for this type
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION2
04/07/2016122688449Open ↗
04/18/2011120659466Open ↗
▸BISWORK PERMIT APPLICATION1
04/19/2011120659466Open ↗
▸Seals & Professional Certifications34
▸DOB NOWDPL-1: Design Professional Seal & Signature13
08/27/2026M01049212-I1Open ↗
08/27/2026M00975845-S1Open ↗
08/27/2026M00975845-I1Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWProgress Inspector Seal & Signature8
09/01/2026M01049212-I1Open ↗
09/01/2026M00975845-S1Open ↗
08/29/2026M00992680-P1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
09/01/2026M01049212-I1Open ↗
09/01/2026M01049212-I1Open ↗
09/01/2026M00975845-S1Open ↗
Showing 3 of 8 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
04/07/2016122688449Open ↗
04/18/2011120659466Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
04/07/2016122688449Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
04/18/2011120659466Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
04/07/2016122688449Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
04/07/2016122688449Open ↗
▸Safety & Tenant Protection14
▸DOB NOWHPD-2: Clinton Special District Anti-Harassment Checklist13
08/13/2026M00975845-S1Open ↗
08/13/2026M01119269-P1Open ↗
08/13/2026M01119269-S2Open ↗
Showing 3 of 13 on file for this type
▸BISANTI-HARASSMENT CHECKLIST: CLINTON1
04/07/2016122688449Open ↗
▸Environmental & Asbestos12
▸DOB NOWDEP ACP-5: Asbestos Assessment Report10
08/27/2026M01049212-I1Open ↗
08/27/2026M00975845-I1Open ↗
08/27/2026M00975845-S1Open ↗
Showing 3 of 10 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
04/18/2011120659466Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
04/07/2016122688449Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
04/07/2016122688449Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
04/18/2011120659466Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
04/07/2016122688449Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET2
04/07/2016122688449Open ↗
04/18/2011120659466Open ↗
▸Other Documents2
▸DOB NOWManufacturer's Specifications1
08/13/2026M01068655-I1Open ↗
▸DOB NOWCalculations1
08/13/2026M01068655-I1Open ↗