← Back
Two family brick
364 CLERMONT AVENUE
BROOKLYN · BIN 3059481
💬 Discuss this project
1899Year Built
3Stories
B1Building Class
R6BZoning
3,312 sfGross Floor Area
2Units
Rent Stabilized7 Open Violations ▸FDNY Report ↗
Two family brick · 2,358 sf lot · 1.4 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingCivil
Permit Issued — active, not yet Signed-off
Floor 3Under Construction22p · 1 filing · 20 docs
Floor 2Under Construction23p · 1 filing · 20 docs
Floor 1Under Construction23p · 1 filing · 20 docs
CellarUnder Construction2p · 1 filing · 20 docs
Sub-BasementUnder Construction22p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/30/2025$3.4M—— → —$1,011/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SK ARCHITECTURAL DESIGN GROUP506/09/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MOSSO CONSTRUCTION INCGeneral Contractor504/09/2026
SAMUEL & SONS P & H INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP5616206/09/2026
Building Lifecycle
All (71)Filed (5)Permit Issued (4)Violation (8)Inspection (12)Objection (13)Special Inspection (29)
09/02/2026
Objection raised — Scope
08/12/2026
Objection resolved — Addressed
08/12/2026
Objection resolved — Open
08/12/2026
Objection resolved — Addressed
08/12/2026
Objection resolved — Open
08/12/2026
Objection resolved — Open
08/07/2026
Objection raised — Scope
08/07/2026
Objection raised — Scope
08/07/2026
Objection raised — Scope
08/07/2026
Objection raised — Scope
08/07/2026
Objection raised — Scope
08/06/2026
Inspection — Pass-Final PL - More than 10 Requested Floors
Pass
View inspection ↗
08/05/2026
Objection resolved — Addressed
07/31/2026
Inspection — Pass-Final PL - More than 10 Requested Floors
Pass
View inspection ↗
07/24/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/22/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/10/2026
Objection raised — Other
06/10/2026
Special inspection requirement — HVAC-R and service water heating system controls
SHAHRIAR QUAYYUM
06/10/2026
Special inspection requirement — Energy Code Compliance Inspections
SHAHRIAR QUAYYUM
06/10/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
SHAHRIAR QUAYYUM
06/09/2026
Filed — Alteration
Renvation of existing 2-family dwelling.
B01238632-P1
06/09/2026
Filed — Alteration
Renvation of existing 2-family dwelling.
B01238632-P2
05/01/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/25/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/26/2026
Permit issued — Mechanical Systems
B01238632-S1-GC-CX
01/22/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/22/2025
Inspection — Pass-Final SP - Up to 3 Requested Floors
Pass
View inspection ↗
12/11/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
11/25/2025
Violation issued (HPD, open)
I
11/21/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/30/2025
Permit issued — Plumbing
B01238632-S2-PL
10/24/2025
Filed — Alteration
Renvation of existing 2-family dwelling.
B01238632-S2
10/21/2025
Permit issued — Earth Work
B01238632-S1-GC-CX
09/18/2025
Filed — Alteration
Renvation of existing 2-family dwelling.
B01238632-S1
09/18/2025
Permit issued — General Construction
B01238632-I1-GC
06/21/2025
Special inspection requirement — Structural Cold-Formed Steel
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Structural Steel - Details
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Structural Steel - Welding
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Concrete - Cast-In-Place
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Subgrade Inspections
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Mechanical Systems
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Fire-Resistance Rated Construction
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Structural Wood Frame
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Final
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Footing and Foundation
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Structural Steel - High Strength Bolting
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Insulation placement and R values
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Interior lighting power
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Lighting in dwelling units
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Protection of exposed foundation insulation
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Lighting controls
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Fenestration air leakage
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Air barrier - visual inspection
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Ventilation and air distribution system
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Duct leakage testing, insulation and design
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Energy Code Compliance Inspections
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Construction Utilizing CLT or SCL, Type IV
SHAHRIAR QUAYYUM
06/21/2025
Special inspection requirement — Masonry
SHAHRIAR QUAYYUM
Latest 60 of 71 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedMOSSO CONSTRUCTION INC01/26/2026
DOB NOWPlumbingPermit IssuedSAMUEL & SONS P & H INC10/30/2025
DOB NOWEarth WorkPermit IssuedMOSSO CONSTRUCTION INC10/21/2025
DOB NOWGeneral ConstructionPermit IssuedMOSSO CONSTRUCTION INC09/18/2025
1 project · most recent 06/09/2026
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
06/09/2026Permit IssuedMOSSO CONSTRUCTION INCAir Conditioning Systems
Cooling
Lg LG KUSXB361A 39,000 BTU · Split System ×2
LG KUSXD421A 48,000 BTU · Split System ×1
LG KUSXB481A 53,000 BTU · Split System ×1
1 project · most recent 06/09/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
06/09/2026Permit IssuedSAMUEL & SONS P & H INCGas, Storm, Water/Sanitary
1 project · most recent 10/15/2025
General Wiring
FiledStatusContractorScope
10/15/2025Permit IssuedAPPROVED ELECTRIC CORP.General Wiring
1 project · most recent 06/09/2026
Steel Concrete Masonry Wood
FiledStatusContractorScope
06/09/2026Permit IssuedMOSSO CONSTRUCTION INCSteel, Concrete, Masonry, Wood
▾Field Inspections (DOB CAP) — 12
DateTypeResultReport
08/06/2026Pass-Final PL - More than 10 Requested FloorsPassView ↗
07/31/2026Pass-Final PL - More than 10 Requested FloorsPassView ↗
07/24/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/22/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
05/01/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/25/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/22/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/22/2025Pass-Final SP - Up to 3 Requested FloorsPassView ↗
12/11/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
11/21/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/11/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/07/2024Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 29
DateRequirementInspectorRole
06/10/2026HVAC-R and service water heating system controlsSHAHRIAR QUAYYUMenergy_progress
06/10/2026Energy Code Compliance InspectionsSHAHRIAR QUAYYUMprogress
06/10/2026HVAC-R and service water piping design and insulationSHAHRIAR QUAYYUMenergy_progress
06/21/2025Structural Cold-Formed SteelSHAHRIAR QUAYYUMspecial
06/21/2025Structural Steel - DetailsSHAHRIAR QUAYYUMspecial
06/21/2025Structural Steel - WeldingSHAHRIAR QUAYYUMspecial
06/21/2025Concrete - Cast-In-PlaceSHAHRIAR QUAYYUMspecial
06/21/2025Subgrade InspectionsSHAHRIAR QUAYYUMspecial
06/21/2025Structural Stability – Alterations of existing buildingsSHAHRIAR QUAYYUMspecial
06/21/2025Mechanical SystemsSHAHRIAR QUAYYUMspecial
06/21/2025Fire-Resistance Rated ConstructionSHAHRIAR QUAYYUMprogress
06/21/2025Structural Wood FrameSHAHRIAR QUAYYUMprogress
06/21/2025FinalSHAHRIAR QUAYYUMprogress
06/21/2025Footing and FoundationSHAHRIAR QUAYYUMprogress
06/21/2025Structural Steel - High Strength BoltingSHAHRIAR QUAYYUMspecial
06/21/2025Insulation placement and R valuesSHAHRIAR QUAYYUMenergy_progress
06/21/2025Interior lighting powerSHAHRIAR QUAYYUMenergy_progress
06/21/2025Lighting in dwelling unitsSHAHRIAR QUAYYUMenergy_progress
06/21/2025Protection of exposed foundation insulationSHAHRIAR QUAYYUMenergy_progress
06/21/2025Lighting controlsSHAHRIAR QUAYYUMenergy_progress
06/21/2025Fenestration air leakageSHAHRIAR QUAYYUMenergy_progress
06/21/2025Air barrier - visual inspectionSHAHRIAR QUAYYUMenergy_progress
06/21/2025Ventilation and air distribution systemSHAHRIAR QUAYYUMenergy_progress
06/21/2025Duct leakage testing, insulation and designSHAHRIAR QUAYYUMenergy_progress
06/21/2025Fenestration and door U-factor and product ratingsSHAHRIAR QUAYYUMenergy_progress
Latest 25 of 29.
▾Documents — 42 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/16/2026B01238632-S2Request digital key ↗
08/16/2026B01238632-S1Request digital key ↗
08/16/2026B01238632-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits5
▸DOB NOWLPC Approval/Permit5
08/16/2026B01238632-S2Open ↗
08/16/2026B01238632-P2Open ↗
08/15/2026B01238632-P1Open ↗
Showing 3 of 5 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram3
08/15/2026B01238632-P1Open ↗
08/13/2026B01238632-S1Open ↗
08/13/2026B01238632-P1Open ↗
▸Seals & Professional Certifications11
▸DOB NOWProgress Inspector Seal & Signature5
09/23/2026B01238632-S1Open ↗
09/23/2026B01238632-S1Open ↗
09/02/2026B01238632-S2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/16/2026B01238632-S1Open ↗
08/16/2026B01238632-I1Open ↗
08/16/2026B01238632-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature1
09/23/2026B01238632-S1Open ↗
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026B01238632-S1Open ↗
08/13/2026B01238632-P1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/16/2026B01238632-S1Open ↗
08/16/2026B01238632-I1Open ↗
08/16/2026B01238632-P2Open ↗
Showing 3 of 5 on file for this type
▸Inspections & Test Reports1
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/13/2026B01238632-S1Open ↗
▸Approvals, Objections & Sign-offs2
▸DOB NOWLandmark Approval2
08/13/2026B01238632-P1Open ↗
08/13/2026B01238632-S2Open ↗
▸Other Documents8
▸DOB NOWPlot Diagram3
08/15/2026B01238632-P1Open ↗
08/13/2026B01238632-P1Open ↗
08/13/2026B01238632-S1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026B01238632-P1Open ↗
08/13/2026B01238632-S1Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026B01238632-S1Open ↗
08/13/2026B01238632-P1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026B01238632-S1Open ↗