← Back
Miscellaneous one family
365 UNION STREET
BROOKLYN · BIN 3007116
💬 Discuss this project
1899Year Built
3Stories
A9Building Class
R6BZoning
3,200 sfGross Floor Area
1Units
Rent Stabilized18 Open Violations ▸
Miscellaneous one family · 1,800 sf lot · 1.78 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Roof3p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
365 UNION BPC PARTNERS LL103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BAXT INGUI ARCHITECTS509/29/2025
NY BUILDING ASSOCIATES INC103/07/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BROOKLYN SOLARWORKS103/21/2026
GAMILL ENGINEERING, PC1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BROOKLYN SOLARWORKS LLCGeneral Contractor203/21/2026
MLZ GENERAL CONSTRUCTIONGeneral Contractor204/09/2026
SUPER CHARGED ELEC. INC.Electrical103/22/2026
NEW AMSTERDAM PLBG & HTGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JSPECS,INC9429509/29/2025
NKM ENGINEERING PLLC6244103/07/2025
Building Lifecycle
All (79)Filed (6)Permit Issued (4)Signed Off (3)Violation (19)Inspection (3)Objection (14)Special Inspection (30)
05/06/2026
Violation issued (HPD, open)
A
11/20/2025
Violation issued (HPD, open)
I
11/06/2025
Signed off — Alteration
RENOVATION OF BASEMENT FLOOR, RELOCATE KITCHEN TO FIRST FLOOR, HVAC WORK ON CELLAR BASEMENT AND FIRST FLOORS. NO WORK ON 2ND OR 3RD FLOORS.
B01108987-I1
11/05/2025
Permit issued — Mechanical Systems
B01108987-I1-MS
10/29/2025
Signed off — Alteration
RENOVATION OF BASEMENT FLOOR, RELOCATE KITCHEN TO FIRST FLOOR, HVAC WORK ON CELLAR BASEMENT AND FIRST FLOORS. NO WORK ON 2ND OR 3RD FLOORS.
B01108987-S1
10/10/2025
Objection resolved — Addressed
10/10/2025
Objection resolved — Addressed
10/10/2025
Special inspection requirement — Mechanical Systems
Jeffrey Stones
10/10/2025
Special inspection requirement — Lighting in dwelling units
Jeffrey Stones
10/10/2025
Special inspection requirement — HVAC-R and service water heating equipment
Jeffrey Stones
10/10/2025
Special inspection requirement — HVAC-R and service water heating system controls
Jeffrey Stones
10/10/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Jeffrey Stones
10/10/2025
Special inspection requirement — Energy Code Compliance Inspections
Jeffrey Stones
10/10/2025
Special inspection requirement — Final
Jeffrey Stones
10/10/2025
Special inspection requirement — Fire-Resistance Rated Construction
Jeffrey Stones
10/10/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jeffrey Stones
10/07/2025
Objection raised — Cost
10/07/2025
Objection raised — Fire_Protection
09/29/2025
Filed — Alteration
RENOVATION OF BASEMENT FLOOR, RELOCATE KITCHEN TO FIRST FLOOR, HVAC WORK ON CELLAR BASEMENT AND FIRST FLOORS. NO WORK ON 2ND OR 3RD FLOORS.
B01108987-P3
09/26/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jeffrey Stones
09/26/2025
Special inspection requirement — Mechanical Systems
Jeffrey Stones
09/26/2025
Special inspection requirement — Energy Code Compliance Inspections
Jeffrey Stones
09/26/2025
Special inspection requirement — Final
Jeffrey Stones
09/26/2025
Special inspection requirement — Fire-Resistance Rated Construction
Jeffrey Stones
09/26/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Jeffrey Stones
09/26/2025
Special inspection requirement — Lighting in dwelling units
Jeffrey Stones
09/26/2025
Special inspection requirement — HVAC-R and service water heating equipment
Jeffrey Stones
09/26/2025
Special inspection requirement — HVAC-R and service water heating system controls
Jeffrey Stones
06/16/2025
Objection resolved — Addressed
06/16/2025
Objection resolved — Addressed
06/16/2025
Objection resolved — Addressed
06/16/2025
Objection resolved — Addressed
06/16/2025
Objection resolved — Addressed
06/11/2025
Violation issued (HPD, open)
A
05/06/2025
Signed off — Alteration
INSTALLATION OF SOLAR PV SYSTEM ON THE EXISTING ROOFTOP. NO CHANGES TO USE, EGRESS OR OCCUPANCY.
B01189230-I1
03/17/2025
Permit issued — Solar
B01189230-I1-SL
03/13/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/13/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/12/2025
Objection raised — Energy
03/12/2025
Objection raised — Other
03/12/2025
Objection raised — Inspections
03/12/2025
Objection raised — Other
03/12/2025
Objection raised — Scope
03/07/2025
Filed — Alteration
INSTALLATION OF SOLAR PV SYSTEM ON THE EXISTING ROOFTOP. NO CHANGES TO USE, EGRESS OR OCCUPANCY.
B01189230-I1
03/06/2025
Filed — Alteration
RENOVATION OF BASEMENT FLOOR, RELOCATE KITCHEN TO FIRST FLOOR, HVAC WORK ON CELLAR BASEMENT AND FIRST FLOORS. NO WORK ON 2ND OR 3RD FLOORS.
B01108987-P2
03/06/2025
Filed — Alteration
RENOVATION OF BASEMENT FLOOR, RELOCATE KITCHEN TO FIRST FLOOR, HVAC WORK ON CELLAR BASEMENT AND FIRST FLOORS. NO WORK ON 2ND OR 3RD FLOORS.
B01108987-P1
03/03/2025
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
03/03/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
03/03/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
03/03/2025
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
03/03/2025
Special inspection requirement — Final
NARESH MAHANGU
02/27/2025
Special inspection requirement — Fire-Resistance Rated Construction
Jeffrey Stones
02/27/2025
Special inspection requirement — Final
Jeffrey Stones
02/27/2025
Special inspection requirement — Energy Code Compliance Inspections
Jeffrey Stones
02/27/2025
Special inspection requirement — Mechanical Systems
Jeffrey Stones
02/27/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jeffrey Stones
02/27/2025
Special inspection requirement — HVAC-R and service water heating system controls
Jeffrey Stones
02/27/2025
Special inspection requirement — HVAC-R and service water heating equipment
Jeffrey Stones
12/24/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/17/2024
Permit issued — Plumbing
B01108987-S1-PL
Latest 60 of 79 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offMLZ GENERAL CONSTRUCTION11/05/2025
DOB NOWSolarSigned-offBROOKLYN SOLARWORKS LLC03/17/2025
DOB NOWPlumbingSigned-offEDWARD FITZSIMMONS12/17/2024
DOB NOWGeneral ConstructionSigned-offMLZ GENERAL CONSTRUCTION10/22/2024
BISPLISSUEDROCKFORD P & H CORP10/05/2000
BISOTISSUEDMLZ GENERAL CONSTRUCTION02/23/2000
2 projects · most recent 03/28/2025
General Wiring
FiledStatusContractorScope
03/28/2025CompleteSUPER CHARGED ELEC. INC.General Wiring
03/04/2025CompleteBROOKYLN SOLARWORKS, LLC—
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
03/13/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/13/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
12/24/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 32
DateRequirementInspectorRole
10/10/2025Mechanical SystemsJeffrey Stonesspecial
10/10/2025Lighting in dwelling unitsJeffrey Stonesenergy_progress
10/10/2025HVAC-R and service water heating equipmentJeffrey Stonesenergy_progress
10/10/2025HVAC-R and service water heating system controlsJeffrey Stonesenergy_progress
10/10/2025HVAC-R and service water piping design and insulationJeffrey Stonesenergy_progress
10/10/2025Energy Code Compliance InspectionsJeffrey Stonesprogress
10/10/2025FinalJeffrey Stonesprogress
10/10/2025Fire-Resistance Rated ConstructionJeffrey Stonesprogress
10/10/2025Fire-Resistant Penetrations and JointsJeffrey Stonesspecial
09/26/2025Fire-Resistant Penetrations and JointsJeffrey Stonesspecial
09/26/2025Mechanical SystemsJeffrey Stonesspecial
09/26/2025Energy Code Compliance InspectionsJeffrey Stonesprogress
09/26/2025FinalJeffrey Stonesprogress
09/26/2025Fire-Resistance Rated ConstructionJeffrey Stonesprogress
09/26/2025HVAC-R and service water piping design and insulationJeffrey Stonesenergy_progress
09/26/2025Lighting in dwelling unitsJeffrey Stonesenergy_progress
09/26/2025HVAC-R and service water heating equipmentJeffrey Stonesenergy_progress
09/26/2025HVAC-R and service water heating system controlsJeffrey Stonesenergy_progress
03/03/2025Air barrier - visual inspectionNARESH MAHANGUenergy_progress
03/03/2025Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
03/03/2025Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
03/03/2025Energy Code Compliance InspectionsNARESH MAHANGUprogress
03/03/2025FinalNARESH MAHANGUprogress
02/27/2025Fire-Resistance Rated ConstructionJeffrey Stonesprogress
02/27/2025FinalJeffrey Stonesprogress
Latest 25 of 32.
▾Documents — 34 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/22/2026B01189230-I1Request digital key ↗
08/20/2026B01108987-I1Request digital key ↗
08/20/2026B01108987-S1Request digital key ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications21
▸DOB NOWProgress Inspector Seal & Signature11
08/31/2026B01108987-I1Open ↗
08/31/2026B01108987-I1Open ↗
08/31/2026B01108987-I1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/22/2026B01189230-I1Open ↗
08/20/2026B01108987-I1Open ↗
08/20/2026B01108987-S1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/31/2026B01108987-I1Open ↗
08/27/2026B01189230-I1Open ↗
08/26/2026B01108987-P3Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/22/2026B01189230-I1Open ↗
08/20/2026B01108987-I1Open ↗
08/20/2026B01108987-S1Open ↗
Showing 3 of 6 on file for this type
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026B01189230-I1Open ↗