← Back
Two stories - detached, small or mid-size
366 SHARROTTS ROAD
STATEN ISLAND · Tottenville-Charleston · BIN 5086798
💬 Discuss this project
1930Year Built
1.75Stories
A1Building Class
R3XZoning
1,034 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 4,740 sf lot · 0.22 FAR built · Flood zone X
Locations of Work
Architecture
Floor 17p · 1 filing · 20 docs
Site & exterior5p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AVID DESIGNS, INC204/06/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HM BUILD AND UPLIFT CORPGeneral Contractor203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AVID DESIGNS, INC.453204/06/2023
Building Lifecycle
All (28)Filed (2)Permit Issued (1)Signed Off (1)Inspection (1)Objection (10)Special Inspection (13)
05/31/2023
Signed off — Alteration
horizontal enlargement of 1 family dwelling, no change of use/egress/occupancy/fire resistance ratings/energy efficiency under this application
S00705524-I1
05/08/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
05/02/2023
Special inspection requirement — Concrete - Cast-In-Place
Jeffrey Geary
05/02/2023
Special inspection requirement — Subgrade Inspections
Jeffrey Geary
05/02/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jeffrey Geary
05/02/2023
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Jeffrey Geary
05/02/2023
Special inspection requirement — Energy Code Compliance Inspections
Jeffrey Geary
05/02/2023
Special inspection requirement — Structural Wood Frame
Jeffrey Geary
05/02/2023
Special inspection requirement — Final
James Carroll
05/02/2023
Special inspection requirement — Footing and Foundation
Jeffrey Geary
05/02/2023
Special inspection requirement — Insulation placement and R values
Jeffrey Geary
05/02/2023
Special inspection requirement — Air barrier - visual inspection
Jeffrey Geary
05/02/2023
Special inspection requirement — Fenestration air leakage
Jeffrey Geary
05/02/2023
Special inspection requirement — Interior lighting power
Jeffrey Geary
05/02/2023
Special inspection requirement — Air barrier — testing
Jeffrey Geary
04/06/2023
Filed — Alteration
horizontal enlargement of 1 family dwelling, no change of use/egress/occupancy/fire resistance ratings/energy efficiency under this application
S00705524-P2
11/18/2022
Permit issued — General Construction
S00705524-I1-GC-CX
06/10/2022
Objection raised — Zoning
06/10/2022
Objection resolved — Addressed
06/10/2022
Objection raised — Zoning
06/10/2022
Objection resolved — Addressed
06/10/2022
Objection raised — Scope
06/10/2022
Objection resolved — Addressed
06/10/2022
Objection raised — Zoning
06/10/2022
Objection resolved — Addressed
06/01/2022
Objection raised — Zoning
06/01/2022
Objection resolved — Addressed
05/12/2022
Filed — Alteration
horizontal enlargement of 1 family dwelling, no change of use/egress/occupancy/fire resistance ratings/energy efficiency under this application
S00705524-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offHM BUILD UPLIFT11/18/2022
BISPLISSUEDQUALITY PLUMBING, INC01/14/1997
BIS—ISSUEDANTHONY MALONE10/11/1996
1 project · most recent 03/05/2023
General Wiring
FiledStatusContractorScope
03/05/2023CompleteHIGH BEAM ELECTRIC CORP.General Wiring
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
05/08/2023Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
05/02/2023Concrete - Cast-In-PlaceJeffrey Gearyspecial
05/02/2023Subgrade InspectionsJeffrey Gearyspecial
05/02/2023Fire-Resistant Penetrations and JointsJeffrey Gearyspecial
05/02/2023Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationJeffrey Gearyspecial
05/02/2023Energy Code Compliance InspectionsJeffrey Gearyprogress
05/02/2023Structural Wood FrameJeffrey Gearyprogress
05/02/2023FinalJames Carrollprogress
05/02/2023Footing and FoundationJeffrey Gearyprogress
05/02/2023Insulation placement and R valuesJeffrey Gearyenergy_progress
05/02/2023Air barrier - visual inspectionJeffrey Gearyenergy_progress
05/02/2023Fenestration air leakageJeffrey Gearyenergy_progress
05/02/2023Interior lighting powerJeffrey Gearyenergy_progress
05/02/2023Air barrier — testing Jeffrey Gearyenergy_progress
▾Documents — 41 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/24/2026S00705524-P2Request digital key ↗
08/24/2026S00705524-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records4
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026S00705524-I1Open ↗
08/13/2026S00705524-P2Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026S00705524-P2Open ↗
08/13/2026S00705524-I1Open ↗
▸Seals & Professional Certifications28
▸DOB NOWProgress Inspector Seal & Signature18
08/26/2026S00705524-I1Open ↗
08/26/2026S00705524-I1Open ↗
08/26/2026S00705524-I1Open ↗
Showing 3 of 18 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
08/26/2026S00705524-I1Open ↗
08/26/2026S00705524-I1Open ↗
08/26/2026S00705524-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026S00705524-P2Open ↗
08/13/2026S00705524-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026S00705524-I1Open ↗
08/13/2026S00705524-P2Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026S00705524-I1Open ↗
▸Other Documents4
▸DOB NOWSite Survey: Initial2
08/13/2026S00705524-I1Open ↗
08/13/2026S00705524-P2Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026S00705524-P2Open ↗
08/13/2026S00705524-I1Open ↗