← Back
Two family converted from one family
367 MANOR ROAD
STATEN ISLAND · Westerleigh-Castleton Corners · BIN 5009055
💬 Discuss this project
1920Year Built
2.5Stories
B3Building Class
R2Zoning
2,048 sfGross Floor Area
2Units
Two family converted from one family · 6,945 sf lot · 0.29 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 29p · 1 filing · 10 docs
Floor 18p · 1 filing · 10 docs
Cellar11p · 2 filings · 13 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ENTHINK ENGINEERS LLC302/26/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NY BUILDING ASSOCIATES INGeneral Contractor203/21/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ENTHINK ENGINEERS LLC6247202/26/2022
Building Lifecycle
All (17)Filed (3)Permit Issued (2)Signed Off (2)Inspection (3)Special Inspection (7)
05/27/2022
Signed off — Alteration
FILE THIS APPLICATION FOR THE INTERIOR RENOVATION OF AN EXISTING TWO AND A HALF STORY BUILDING WITH CELLAR. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
S00646108-I1
05/12/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/08/2022
Signed off — Alteration
FILE FOR PLUMBING WORK FOR INTERIOR RENOVATION OF AN EXISTING TWO AND A HALF STORY BUILDING WITH CELLAR. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
S00653360-I1
03/15/2022
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
03/03/2022
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
03/01/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Sunil Saigal
03/01/2022
Special inspection requirement — Energy Code Compliance Inspections
Sunil Saigal
03/01/2022
Special inspection requirement — Fire-Resistance Rated Construction
Sunil Saigal
03/01/2022
Special inspection requirement — Air barrier - visual inspection
Sunil Saigal
03/01/2022
Special inspection requirement — Fenestration areas
Sunil Saigal
03/01/2022
Special inspection requirement — Fenestration air leakage
Sunil Saigal
03/01/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
Sunil Saigal
02/26/2022
Filed — Alteration
FILE THIS APPLICATION FOR THE INTERIOR RENOVATION OF AN EXISTING TWO AND A HALF STORY BUILDING WITH CELLAR. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
S00646108-P1
01/28/2022
Permit issued — General Construction
S00646108-I1-GC
01/14/2022
Permit issued — Plumbing
S00653360-I1-PL
01/12/2022
Filed — Alteration
FILE THIS APPLICATION FOR THE INTERIOR RENOVATION OF AN EXISTING TWO AND A HALF STORY BUILDING WITH CELLAR. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
S00646108-I1
01/12/2022
Filed — Alteration
FILE FOR PLUMBING WORK FOR INTERIOR RENOVATION OF AN EXISTING TWO AND A HALF STORY BUILDING WITH CELLAR. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
S00653360-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offNY BUILDING ASSOCIATES IN01/28/2022
DOB NOWPlumbingSigned-offAMERICAN STANDARD P&H CORORP.01/14/2022
1 project · most recent 03/07/2022
General Wiring
FiledStatusContractorScope
03/07/2022CompleteVOLTRON ELECTRIC LLCGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
05/12/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/15/2022Pass-Final General Construction Non-Directive 14PassView ↗
03/03/2022Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
03/01/2022Fire-Resistant Penetrations and JointsSunil Saigalspecial
03/01/2022Energy Code Compliance InspectionsSunil Saigalprogress
03/01/2022Fire-Resistance Rated ConstructionSunil Saigalprogress
03/01/2022Air barrier - visual inspectionSunil Saigalenergy_progress
03/01/2022Fenestration areasSunil Saigalenergy_progress
03/01/2022Fenestration air leakageSunil Saigalenergy_progress
03/01/2022Fenestration and door U-factor and product ratingsSunil Saigalenergy_progress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/24/2026S00646108-I1Request digital key ↗
08/24/2026S00646108-P1Request digital key ↗
08/24/2026S00653360-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/24/2026S00646108-I1Open ↗
08/24/2026S00646108-P1Open ↗
08/13/2026S00653360-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/23/2026S00646108-I1Open ↗
08/23/2026S00646108-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026S00646108-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/24/2026S00646108-I1Open ↗
08/24/2026S00646108-P1Open ↗
08/13/2026S00653360-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/24/2026S00646108-I1Open ↗