Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofLic Property Holdings, LLC.Under Construction54p · 1 filing · 20 docs
ArchitectureCivilFire ProtectionGeneralStructural
Issued Permit Scope
General Construction
PROPOSED TO INSTALL NEW SPRINKLER & STANDPIPE SYSTEM FOR 6-STORY MIXED USE BUILDING.
On file for this project
65 documents · 7 drawing sheets
BulkheadLic Property Holdings, LLC.Under Construction3p · 1 filing · 20 docs
ArchitectureMechanical
PROPOSED TO INSTALL NEW SPRINKLER & STANDPIPE SYSTEM FOR 6-STORY MIXED USE BUILDING.
On file for this project
65 documents · 3 drawing sheets
Floor 6Lic Property Holdings, LLC.Under Construction67p · 1 filing · 20 docs
ArchitectureMechanicalStructural
Issued Permit Scope
General Construction · Structural
PROPOSED TO INSTALL NEW SPRINKLER & STANDPIPE SYSTEM FOR 6-STORY MIXED USE BUILDING.
On file for this project
65 documents · 2 drawing sheets
Floor 5Lic Property Holdings, LLC.Under Construction84p · 1 filing · 20 docs
ArchitectureFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Standpipe · Structural
PROPOSED TO INSTALL NEW SPRINKLER & STANDPIPE SYSTEM FOR 6-STORY MIXED USE BUILDING.
On file for this project
65 documents · 2 drawing sheets
Floor 4Lic Property Holdings, LLC.Under Construction87p · 2 filings · 20 docs
ArchitectureElectricalEquipmentFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Protection and Mechanical Methods · Standpipe · Structural
PROPOSED TO INSTALL NEW SPRINKLER & STANDPIPE SYSTEM FOR 6-STORY MIXED USE BUILDING.
On file for this project
65 documents · 2 drawing sheets
INSTALLATION OF TEMPORARY NEEDLE BEAM AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY SHALL COMPLY WITH CHAPTER#33 OF 2022 THE NY BUILDING CODE.
On file for this project
2 documents
Floor 3Lic Property Holdings, LLC.Under Construction85p · 1 filing · 20 docs
ArchitectureFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Standpipe · Structural
PROPOSED TO INSTALL NEW SPRINKLER & STANDPIPE SYSTEM FOR 6-STORY MIXED USE BUILDING.
On file for this project
65 documents · 3 drawing sheets
Floor 2Lic Property Holdings, LLC.Under Construction69p · 1 filing · 20 docs
ArchitectureMechanicalStructural
Issued Permit Scope
General Construction · Structural
PROPOSED TO INSTALL NEW SPRINKLER & STANDPIPE SYSTEM FOR 6-STORY MIXED USE BUILDING.
On file for this project
65 documents · 4 drawing sheets
Floor 1Lic Property Holdings, LLC.Under Construction85p · 3 filings · 20 docs
ArchitectureFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Standpipe · Structural
PROPOSED TO INSTALL NEW SPRINKLER & STANDPIPE SYSTEM FOR 6-STORY MIXED USE BUILDING.
On file for this project
65 documents · 3 drawing sheets
PROPOSED 10' CURB CUT ON 34TH STREET 101' SOUTH OF 37TH AVENUE, FILED IN CONJUCTION WITH NB Q00654121
On file for this project
2 documents · 1 drawing sheet
PROPOSED 14' CURB CUT ON 37TH AVENUE 93'-0" WEST OF 34TH STREET, FILED IN CONJUCTION WITH NB Q00654121
On file for this project
2 documents · 1 drawing sheet
CellarLic Property Holdings, LLC.Under Construction87p · 1 filing · 20 docs
ArchitectureFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
Foundation · General Construction · Mechanical Systems · Plumbing · Standpipe
PROPOSED TO INSTALL NEW SPRINKLER & STANDPIPE SYSTEM FOR 6-STORY MIXED USE BUILDING.
On file for this project
65 documents · 5 drawing sheets
Site & exteriorLic Property Holdings, LLC.Under Construction35p · 6 filings · 20 docs
ArchitectureEquipmentGeneralMechanicalPlumbingStructural
Issued Permit Scope
Construction Fence · Protection and Mechanical Methods · Sidewalk Shed · Supported Scaffold · Support of Excavation
INSTALLATION OF 300 psf SIDEWALK SHED AS PER PLANS. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE 2014 CODE. NO CHANGE INUSE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
On file for this project
4 documents · 4 drawing sheets
PROPOSED TO INSTALL NEW SPRINKLER & STANDPIPE SYSTEM FOR 6-STORY MIXED USE BUILDING.
On file for this project
65 documents · 12 drawing sheets
PROPOSED INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. WORK SHALL COMPLY WITH CHAPTER #33 OF 2022 THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
On file for this project
2 documents · 5 drawing sheets
Latest 3 of 6 filings on this floor.