← Back
Two stories - detached, small or mid-size
37-27 92 STREET
QUEENS · Jackson Heights · BIN 4036477
💬 Discuss this project
1930Year Built
2.5Stories
A1Building Class
R5Zoning
1,824 sfGross Floor Area
1Units
Rent Stabilized
Two stories - detached, small or mid-size · 2,100 sf lot · 0.87 FAR built · Flood zone X
Locations of Work
PlumbingGeneral
Roof1p · 1 filing · 6 docs
Floor 21p · 1 filing · 6 docs
Floor 11p · 1 filing · 4 docs
Cellar3p · 2 filings · 10 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/21/2023$940K—— → —$515/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BASSIRI402/12/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ECDESIGN STUDIO803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
R & T ELECTRICAL CORPElectrical103/22/2026
KLE CONSTRUCTION INCGeneral Contractor107/08/2026
CATMAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BASSIRI8394202/12/2024
Building Lifecycle
All (15)Filed (4)Permit Issued (2)Signed Off (2)Inspection (4)Special Inspection (3)
05/08/2024
Signed off — Alteration
RENOVATION OF EXISTING CELLAR, FIRST, SECOND FLOOR AND ATTIC WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q00976321-I1
05/08/2024
Signed off — Alteration
RENOVATION OF EXISTING CELLAR, FIRST, SECOND FLOOR AND ATTIC WITH PLUMBING WORK: RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW BOILER AND HOT WATER HEATER ON CELLAR; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q00976326-I1
03/18/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
02/13/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
FARHAD BASSIRI-TEHRANI
02/13/2024
Special inspection requirement — Fire-Resistance Rated Construction
FARHAD BASSIRI-TEHRANI
02/13/2024
Special inspection requirement — Energy Code Compliance Inspections
FARHAD BASSIRI-TEHRANI
02/12/2024
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST, SECOND FLOOR AND ATTIC WITH PLUMBING WORK: RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW BOILER AND HOT WATER HEATER ON CELLAR; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q00976326-P1
02/12/2024
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST, SECOND FLOOR AND ATTIC WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q00976321-P1
02/05/2024
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
02/05/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/05/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
12/26/2023
Permit issued — Plumbing
Q00976326-I1-PL
12/18/2023
Permit issued — General Construction
Q00976321-I1-GC
12/14/2023
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST, SECOND FLOOR AND ATTIC WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q00976321-I1
12/14/2023
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST, SECOND FLOOR AND ATTIC WITH PLUMBING WORK: RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW BOILER AND HOT WATER HEATER ON CELLAR; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q00976326-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCATMAN PLUMBING INC12/26/2023
DOB NOWGeneral ConstructionSigned-offKLE CONSTRUCTION INC12/18/2023
1 project · most recent 03/18/2024
General Wiring
FiledStatusContractorScope
03/18/2024CompleteR & T ELECTRICAL CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
03/18/2024Pass-Final General Construction Non-Directive 14PassView ↗
02/05/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
02/05/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/05/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
02/13/2024Fire-Resistant Penetrations and JointsFARHAD BASSIRI-TEHRANIspecial
02/13/2024Fire-Resistance Rated ConstructionFARHAD BASSIRI-TEHRANIprogress
02/13/2024Energy Code Compliance InspectionsFARHAD BASSIRI-TEHRANIprogress
▾Documents — 10 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/23/2026Q00976321-P1Request digital key ↗
08/23/2026Q00976321-I1Request digital key ↗
08/23/2026Q00976326-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/23/2026Q00976321-I1Open ↗
08/23/2026Q00976321-P1Open ↗
08/23/2026Q00976326-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature1
08/25/2026Q00976321-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/25/2026Q00976321-I1Open ↗