← Back
Two family frame
37-36 93 STREET
QUEENS · Jackson Heights · BIN 4036442
💬 Discuss this project
1930Year Built
2Stories
B2Building Class
R5Zoning
2,052 sfGross Floor Area
2Units
0 Open Violations
Two family frame · 2,200 sf lot · 0.93 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 26p · 2 filings · 16 docs
Floor 16p · 2 filings · 16 docs
Cellar8p · 2 filings · 16 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/03/2021$1.2M—Private party → Private party$570/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ALPHA HOME DESIGN LLC406/23/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ECDESIGN STUDIO803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HAIAN HONEST RENOVATIONGeneral Contractor303/21/2026
KJK ELECTRIC INCElectrical103/22/2026
YILIN CONSTRUCTION INCGeneral Contractor107/08/2026
CATMAN PLUMBING INCPlumbing107/08/2026
Building Lifecycle
All (15)Filed (4)Permit Issued (3)Signed Off (2)Violation (2)Special Inspection (4)
07/06/2021
Signed off — Alteration
INTERIOR RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q00482173-I1
07/06/2021
Signed off — Alteration
INTERIOR RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH PLUMBING WORK: RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW COMBI BOILERS ON CELLAR. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q00482178-I1
06/23/2021
Filed — Alteration
INTERIOR RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q00482173-P1
06/23/2021
Special inspection requirement — Energy Code Compliance Inspections
YAN GAO
06/23/2021
Special inspection requirement — Fire-Resistance Rated Construction
YAN GAO
06/23/2021
Special inspection requirement — Energy Code Compliance Inspections
YAN GAO
06/23/2021
Special inspection requirement — Fire-Resistance Rated Construction
YAN GAO
05/28/2021
Filed — Alteration
INTERIOR RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH PLUMBING WORK: RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW COMBI BOILERS ON CELLAR. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q00482178-P1
04/09/2021
Permit issued — General Construction
Q00482173-I1-GC
03/19/2021
Permit issued — Plumbing
Q00482178-I1-PL
03/15/2021
Permit issued — General Construction
Q00482173-I1-GC
03/12/2021
Filed — Alteration
INTERIOR RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q00482173-I1
03/12/2021
Filed — Alteration
INTERIOR RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH PLUMBING WORK: RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW COMBI BOILERS ON CELLAR. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q00482178-I1
09/02/1999
Violation issued (ECB, closed)
Quality of Life
09/02/1999
Violation issued (ECB, closed)
Quality of Life
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offHAIAN HONEST RENOVATION04/09/2021
DOB NOWPlumbingSigned-offCATMAN PLUMBING INC03/19/2021
DOB NOWGeneral ConstructionSigned-offYILIN CONSTRUCTION INC03/15/2021
1 project · most recent 03/22/2021
General Wiring
FiledStatusContractorScope
03/22/2021CompleteKJK ELECTRIC INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
06/23/2021Energy Code Compliance InspectionsYAN GAOprogress
06/23/2021Fire-Resistance Rated ConstructionYAN GAOprogress
06/23/2021Energy Code Compliance InspectionsYAN GAOprogress
06/23/2021Fire-Resistance Rated ConstructionYAN GAOprogress
▾Documents — 16 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/27/2026Q00482173-I1Request digital key ↗
08/27/2026Q00482173-P1Request digital key ↗
08/27/2026Q00482178-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/27/2026Q00482173-I1Open ↗
08/27/2026Q00482173-P1Open ↗
08/13/2026Q00482178-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026Q00482173-P1Open ↗
09/01/2026Q00482173-P1Open ↗
08/30/2026Q00482173-I1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/27/2026Q00482173-I1Open ↗
08/27/2026Q00482173-P1Open ↗
08/13/2026Q00482178-P1Open ↗
Showing 3 of 4 on file for this type