← Back
Unlicensed parking lot
37-38 9 STREET
QUEENS · BIN 4860628
💬 Discuss this project
0Year Built
—Stories
G7Building Class
M1-3Zoning
0 sfGross Floor Area
0Units
Unlicensed parking lot · Owner of record: LIVNO LLC · 2,505 sf lot · 0 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralPlumbingFire Protection
Roof1p · 1 filing · 20 docs
Bulkhead1p · 1 filing · 20 docs
Floor 46p · 2 filings · 20 docs
Floor 32p · 1 filing · 20 docs
Floor 21p · 1 filing · 20 docs
Floor 15p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BH103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
VIKATOS ARCHITECT PC304/01/2024
GR CONSULTING202/20/2024
ANV ENGINEERING PC210/24/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
RITE ONE EXPEDITING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
K-SQUARE DEVELOPERS INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CENTURY TESTING & CONSULT4081404/01/2024
Building Lifecycle
All (47)Filed (7)Permit Issued (1)Objection (9)Special Inspection (30)
05/30/2024
Special inspection requirement — Exterior lighting power
ALDO BRAVO
05/30/2024
Special inspection requirement — Lighting controls
ALDO BRAVO
05/30/2024
Special inspection requirement — Interior lighting power
ALDO BRAVO
05/30/2024
Special inspection requirement — Fenestration areas
ALDO BRAVO
05/30/2024
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
ALDO BRAVO
05/30/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ALDO BRAVO
05/30/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
05/30/2024
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
ALDO BRAVO
05/30/2024
Special inspection requirement — Subgrade Inspections
ALDO BRAVO
05/30/2024
Special inspection requirement — Concrete - Cast-In-Place
ALDO BRAVO
05/30/2024
Special inspection requirement — Masonry
ALDO BRAVO
05/30/2024
Special inspection requirement — Fire-Resistance Rated Construction
ALDO BRAVO
05/30/2024
Special inspection requirement — Energy Code Compliance Inspections
ALDO BRAVO
05/30/2024
Special inspection requirement — Insulation placement and R values
ALDO BRAVO
05/30/2024
Special inspection requirement — Maintenance information
ALDO BRAVO
05/30/2024
Special inspection requirement — Fenestration air leakage
ALDO BRAVO
05/30/2024
Special inspection requirement — Electrical motors and elevators
ALDO BRAVO
05/30/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
ALDO BRAVO
05/30/2024
Special inspection requirement — Air barrier - visual inspection
ALDO BRAVO
05/20/2024
Objection resolved — Addressed
04/09/2024
Objection raised — Other
04/01/2024
Filed — New Building
PROPOSED FOUNDATION WORK FOR NEW BUILDING
Q00852619-P1
03/28/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
03/28/2024
Special inspection requirement — Subgrade Inspections
ALDO BRAVO
03/28/2024
Special inspection requirement — Energy Code Compliance Inspections
ALDO BRAVO
03/28/2024
Special inspection requirement — Fire-Resistance Rated Construction
ALDO BRAVO
03/28/2024
Special inspection requirement — Air barrier - visual inspection
ALDO BRAVO
03/28/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
ALDO BRAVO
03/28/2024
Special inspection requirement — Exterior lighting power
ALDO BRAVO
03/28/2024
Special inspection requirement — Fenestration areas
ALDO BRAVO
03/28/2024
Special inspection requirement — Fenestration air leakage
ALDO BRAVO
03/28/2024
Special inspection requirement — Lighting controls
ALDO BRAVO
03/28/2024
Special inspection requirement — Interior lighting power
ALDO BRAVO
03/19/2024
Permit issued — Construction Fence
Q00887199-I1-FN
03/01/2024
Objection raised — Other
03/01/2024
Objection raised — Structural
03/01/2024
Objection raised — Other
03/01/2024
Objection raised — Admin
03/01/2024
Objection raised — Inspections
03/01/2024
Objection raised — Structural
03/01/2024
Objection raised — Admin
02/20/2024
Filed — Alteration
installation of new hvac system and associated piping.
Q00897298-S1
02/20/2024
Filed — Alteration
installation of new hvac system and associated piping.
Q00897298-I1
01/25/2024
Filed — Alteration
NEW 8' HIGH CONSTRUCTION FENCE
Q00887199-I1
10/24/2023
Filed — New Building
PROPOSED FOUNDATION WORK FOR NEW BUILDING
Q00852619-S2
10/24/2023
Filed — New Building
PROPOSED FOUNDATION WORK FOR NEW BUILDING
Q00852619-S1
05/19/2023
Filed — New Building
PROPOSED FOUNDATION WORK FOR NEW BUILDING
Q00852619-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedK-SQUARE DEVELOPERS INC03/19/2024
1 project · most recent 02/20/2024
Air Conditioning Systems Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
02/20/2024——Air Conditioning Systems, Heating and Air Conditioning Systems, Ventilation Systems
Cooling
Daikin 4MXSS48RMVJA 48,000 BTU ×4
Heat / Cool
Daikin 4MXS48RMVA 192,000 BTU · Heat Pump Outdoor ×4
Ventilation
Greenheck CFD-7 200 CFM ×5
1 project · most recent 04/01/2024
Concrete
FiledStatusContractorScope
04/01/2024——Concrete
1 project · most recent 01/25/2024
Fence
FiledStatusContractorScope
01/25/2024Permit IssuedK-SQUARE DEVELOPERS INCFence
▾Special Inspection Requirements (DOB NOW) — 51
DateRequirementInspectorRole
05/30/2024Exterior lighting powerALDO BRAVOenergy_progress
05/30/2024Lighting controlsALDO BRAVOenergy_progress
05/30/2024Interior lighting powerALDO BRAVOenergy_progress
05/30/2024Fenestration areasALDO BRAVOenergy_progress
05/30/2024Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationALDO BRAVOspecial
05/30/2024Fire-Resistant Penetrations and JointsALDO BRAVOspecial
05/30/2024Subsurface Investigations (Borings/Test Pits)—special
05/30/2024Excavations - Sheeting, Shoring, and BracingALDO BRAVOspecial
05/30/2024Subgrade InspectionsALDO BRAVOspecial
05/30/2024Concrete - Cast-In-PlaceALDO BRAVOspecial
05/30/2024MasonryALDO BRAVOspecial
05/30/2024Fire-Resistance Rated ConstructionALDO BRAVOprogress
05/30/2024Energy Code Compliance InspectionsALDO BRAVOprogress
05/30/2024Insulation placement and R valuesALDO BRAVOenergy_progress
05/30/2024Maintenance informationALDO BRAVOenergy_progress
05/30/2024Fenestration air leakageALDO BRAVOenergy_progress
05/30/2024Electrical motors and elevatorsALDO BRAVOenergy_progress
05/30/2024Fenestration and door U-factor and product ratingsALDO BRAVOenergy_progress
05/30/2024Air barrier - visual inspectionALDO BRAVOenergy_progress
03/28/2024Subsurface Investigations (Borings/Test Pits)—special
03/28/2024Subgrade InspectionsALDO BRAVOspecial
03/28/2024Energy Code Compliance InspectionsALDO BRAVOprogress
03/28/2024Fire-Resistance Rated ConstructionALDO BRAVOprogress
03/28/2024Air barrier - visual inspectionALDO BRAVOenergy_progress
03/28/2024Fenestration and door U-factor and product ratingsALDO BRAVOenergy_progress
Latest 25 of 51.
▾Documents — 75 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/23/2026Q00852619-S2Request digital key ↗
08/23/2026Q00852619-S1Request digital key ↗
08/23/2026Q00852619-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026Q00852619-I1Open ↗
08/13/2026Q00852619-P1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026Q00852619-I1Open ↗
08/13/2026Q00852619-P1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00852619-I1Open ↗
▸Seals & Professional Certifications48
▸DOB NOWProgress Inspector Seal & Signature26
09/01/2026Q00852619-P1Open ↗
09/01/2026Q00852619-P1Open ↗
09/01/2026Q00852619-P1Open ↗
Showing 3 of 26 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature15
09/01/2026Q00852619-P1Open ↗
09/01/2026Q00852619-P1Open ↗
09/01/2026Q00852619-P1Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/23/2026Q00852619-S1Open ↗
08/23/2026Q00852619-I1Open ↗
08/23/2026Q00852619-P1Open ↗
Showing 3 of 7 on file for this type
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026Q00852619-I1Open ↗
08/13/2026Q00852619-P1Open ↗
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist2
08/13/2026Q00852619-P1Open ↗
08/13/2026Q00852619-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00852619-I1Open ↗
▸Inspections & Test Reports4
▸DOB NOWSOIL REPORT3
08/13/2026Q00852619-I1Open ↗
08/13/2026Q00852619-S2Open ↗
08/13/2026Q00852619-P1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q00852619-I1Open ↗
▸Other Documents6
▸DOB NOWSite Survey: Initial2
08/13/2026Q00852619-I1Open ↗
08/13/2026Q00852619-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026Q00852619-I1Open ↗
08/13/2026Q00852619-P1Open ↗
▸DOB NOWProperty Ownership Certification2
08/23/2026Q00852619-I1Open ↗
08/15/2026Q00852619-P1Open ↗