← Back
BuildNYC
Multi-story retail building (2+)
37-44 82ND STREET
QUEENS · Jackson Heights · BIN 4030016
💬 Discuss this project
1929Year Built
2Stories
K2Building Class
C4-3Zoning
4,890 sfGross Floor Area
3Units
0 Active Violations
Multi-story retail building (2+) · 3,000 sf lot · 1.63 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofLong Agents LLC3p · 2 filings · 15 docs
Floor 2Med Spa interior renovations, 2nd floor16p · 2 filings · 20 docs
Floor 1T-Mobile26p · 1 filing · 20 docs
Cellar2nd floor demolition and interior work1p · 1 filing · 12 docs
Site & exteriorT-Mobile1p · 1 filing · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Long Agents2407/08/2026
TRC103/22/2026
Bakers103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Dennis J. Lewis PE401/26/2026
All City Engineering107/23/2025
JLS Designs207/01/2025
Russell M. Baumann, Architect104/03/2025
AL Ffred Architecture311/21/2024
Vincent J. Liotta P.E102/02/2023
Shaaban Engineering110/16/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JLS Designs303/21/2026
J.A.M. Associates1003/21/2026
National Maintenance203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Ridge ConstructionGeneral Contractor304/09/2026
Lebo ElectricElectrical103/22/2026
Abm ConstructionGeneral Contractor104/09/2026
Afgo Mechanical Servicesspecialty_contractor107/08/2026
Richmond Remodeling & ConGeneral Contractor107/08/2026
National MaintenanceSign hanger107/08/2026
Fulton Plumbing & HeatingPlumbing107/08/2026
Stat ElectricElectrical103/21/2026
Rite Way HeatingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Catalpa Special Inspectio2004501/26/2026
SD Testing & Inspection S7010105/13/2025
Vincent J. Liotta P. E1974102/02/2023
Building Lifecycle
All (63)Filed (13)Permit Issued (8)Signed Off (5)Violation (4)Inspection (3)Objection (7)Special Inspection (23)
01/27/2026
Signed off — Alteration
T-MOBILE: GENERAL CONSTRUCTION INCLUSIVE OF PARTITIONS MODIFICATIONS FOR RETAIL REMODEL AS PER PLANS FILED. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
Q01187462-S1
01/27/2026
Special inspection requirement — Final
ERIC BERLENT
01/27/2026
Special inspection requirement — Mechanical Systems
ERIC BERLENT
01/26/2026
Filed — Alteration
T-MOBILE: GENERAL CONSTRUCTION INCLUSIVE OF PARTITIONS MODIFICATIONS FOR RETAIL REMODEL AS PER PLANS FILED. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
Q01187462-P2
01/16/2026
Special inspection requirement — Mechanical Systems
ERIC BERLENT
01/16/2026
Special inspection requirement — Final
ERIC BERLENT
12/15/2025
Filed — Alteration
T-MOBILE: GENERAL CONSTRUCTION INCLUSIVE OF PARTITIONS MODIFICATIONS FOR RETAIL REMODEL AS PER PLANS FILED. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
Q01187462-P1
10/30/2025
Signed off — Alteration
T-MOBILE: GENERAL CONSTRUCTION INCLUSIVE OF PARTITIONS MODIFICATIONS FOR RETAIL REMODEL AS PER PLANS FILED. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
Q01187462-S2
10/30/2025
Signed off — Alteration
T-MOBILE: GENERAL CONSTRUCTION INCLUSIVE OF PARTITIONS MODIFICATIONS FOR RETAIL REMODEL AS PER PLANS FILED. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
Q01187462-I1
09/04/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/02/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/29/2025
Permit issued — Plumbing
Q01213270-S2-PL
07/28/2025
Objection raised — Admin
07/24/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/23/2025
Filed — Alteration
Mechanical system for a 2nd floor med Spa renovation
Q01213270-S3
07/07/2025
Objection resolved — Addressed
07/03/2025
Objection raised — Admin
07/01/2025
Filed — Alteration
Mechanical system for a 2nd floor med Spa renovation
Q01213270-S2
07/01/2025
Permit issued — General Construction
Q01213270-I1-GC
06/24/2025
Special inspection requirement — Shutoff dampers
06/24/2025
Special inspection requirement — Exhaust and Vent Systems in Plenums and Ducts
06/24/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/24/2025
Special inspection requirement — Maintenance information
06/24/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
06/24/2025
Special inspection requirement — Energy Code Compliance Inspections
06/24/2025
Special inspection requirement — Duct leakage testing, insulation and design
06/24/2025
Special inspection requirement — HVAC-R and service water heating equipment
06/24/2025
Special inspection requirement — HVAC-R and service water heating system controls
06/23/2025
Special inspection requirement — Final
06/23/2025
Special inspection requirement — Mechanical Systems
06/11/2025
Objection resolved — Addressed
06/10/2025
Permit issued — Plumbing
Q01187462-S2-PL
05/28/2025
Objection raised — Admin
05/13/2025
Filed — Alteration
Mechanical system for a 2nd floor med Spa renovation
Q01213270-I1
04/10/2025
Permit issued — General Construction
Q01187462-I1-GC
04/07/2025
Permit issued — Mechanical Systems
Q01187462-S1-MS
04/03/2025
Filed — Alteration
T-MOBILE: GENERAL CONSTRUCTION INCLUSIVE OF PARTITIONS MODIFICATIONS FOR RETAIL REMODEL AS PER PLANS FILED. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
Q01187462-S1
04/03/2025
Filed — Alteration
T-MOBILE: GENERAL CONSTRUCTION INCLUSIVE OF PARTITIONS MODIFICATIONS FOR RETAIL REMODEL AS PER PLANS FILED. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
Q01187462-S2
04/03/2025
Filed — Alteration
T-MOBILE: GENERAL CONSTRUCTION INCLUSIVE OF PARTITIONS MODIFICATIONS FOR RETAIL REMODEL AS PER PLANS FILED. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
Q01187462-I1
02/27/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ERIC BERLENT
02/27/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ERIC BERLENT
02/27/2025
Special inspection requirement — Final
ERIC BERLENT
12/09/2024
Objection raised — Admin
12/09/2024
Objection raised — Admin
11/21/2024
Filed — Alteration
Removal of non load bearing exist. partions, doors, cabinetry, suspended clg. and fl. finishess on 2nd fl. Removal of ductwork on rooof above the 2nd fl. of exist. com. bldg as shown on filed plans. No change to C of O, egress, use & bulk of the building.
Q01035286-S2
11/21/2024
Filed — Alteration
Removal of non load bearing exist. partions, doors, cabinetry, suspended clg. and fl. finishess on 2nd fl. Removal of ductwork on rooof above the 2nd fl. of exist. com. bldg as shown on filed plans. No change to C of O, egress, use & bulk of the building.
Q01035286-S1
11/15/2024
Special inspection requirement — Energy Code Compliance Inspections
Alfred Mierzejewski
08/14/2024
Special inspection requirement — Final
Feng Zhang
08/14/2024
Special inspection requirement — Mechanical Systems
05/30/2024
Permit issued — General Construction
Q01035286-I1-GC
05/22/2024
Filed — Alteration
Removal of non load bearing exist. partions, doors, cabinetry, suspended clg. and fl. finishess on 2nd fl. Removal of ductwork on rooof above the 2nd fl. of exist. com. bldg as shown on filed plans. No change to C of O, egress, use & bulk of the building.
Q01035286-I1
05/21/2024
Special inspection requirement — Final
Feng Zhang
02/23/2023
Signed off — Alteration
ERECT ACCESSORY BUSINESS WALL SIGN FOR T-MOBILE, NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00512034-I1
02/15/2023
Signed off — Alteration
REPLACEMENT OF CONDENSER UNIT ON THE ROOFTOP WITH A TOTAL CAPACITY OF 7.5 TONS. NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
Q08016229-I1
02/02/2023
Filed — Alteration
REPLACEMENT OF CONDENSER UNIT ON THE ROOFTOP WITH A TOTAL CAPACITY OF 7.5 TONS. NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
Q08016229-I1
02/02/2023
Permit issued — Mechanical Systems
Q08016229-I1-MS
10/20/2021
Permit issued — Sign
Q00512034-I1-SG
10/16/2021
Filed — Alteration
ERECT ACCESSORY BUSINESS WALL SIGN FOR T-MOBILE, NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00512034-I1
10/16/2021
Special inspection requirement — Final
AHMED SHAABAN
11/26/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Latest 60 of 63 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedLS Plumbing08/29/2025
DOB NOWGeneral ConstructionSigned-offAbm Construction07/01/2025
DOB NOWPlumbingSigned-offFulton Plumbing & Heating06/10/2025
DOB NOWGeneral ConstructionSigned-offRidge Construction04/10/2025
DOB NOWMechanical SystemsSigned-offRidge Construction04/07/2025
DOB NOWGeneral ConstructionPermit IssuedRichmond Remodeling & Con05/30/2024
DOB NOWMechanical SystemsSigned-offAfgo Mechanical Services02/02/2023
DOB NOWSignSigned-offNational Maintenance10/20/2021
BISEQISSUEDColgate Enterprise01/28/2015
BISEQISSUEDColgate Enterprise01/23/2015
BIS—ISSUEDCad Signs NYC10/17/2014
BISOTISSUEDGsi Systems05/24/2013
BISMHISSUEDGsi Systems03/21/2013
BIS—ISSUEDTru Art Sign Co04/23/2008
BISPLISSUEDPrimo P & H02/16/2005
BISOTISSUEDSchimenti Construction Co02/10/2005
BISMHISSUEDSchimenti Construction Co02/10/2005
BIS—ISSUEDTru Sign Co01/04/2005
BIS—ISSUEDUniversal Electric Sign Co08/22/1995
BISPLISSUEDWolford07/14/1995
BISEQISSUEDTurner Busch06/19/1995
BISMHISSUEDTurner Busch06/19/1995
1 project · most recent 07/23/2025
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/23/2025Signed-offAbm ConstructionHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Midea MDV-V48WMN1T 48,000 BTU · Vrf Outdoor ×2
Ventilation
Renewaire HE10INV 605 CFM · Erv ×1
1 project · most recent 07/23/2025
Water/Sanitary
FiledStatusContractorScope
07/23/2025Permit IssuedRite Way HeatingWater/Sanitary
4 projects · most recent 03/23/2026
General Wiring
FiledStatusContractorScope
03/23/2026CompleteBLZ ElectricGeneral Wiring
09/10/2025CompleteLebo ElectricGeneral Wiring
04/10/2025CompleteNapstar ElectricGeneral Wiring
10/23/2021Permit IssuedNational Maintenance—
1 project · most recent 11/21/2024
FiledStatusContractorScope
11/21/2024Permit IssuedRichmond Remodeling & Con1 scope_items
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
09/04/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/02/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/24/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 23
DateRequirementInspectorRole
01/27/2026FinalERIC BERLENTprogress
01/27/2026Mechanical SystemsERIC BERLENTspecial
01/16/2026Mechanical SystemsERIC BERLENTspecial
01/16/2026FinalERIC BERLENTprogress
06/24/2025Shutoff dampers—energy_progress
06/24/2025Exhaust and Vent Systems in Plenums and Ducts—special
06/24/2025Fire-Resistant Penetrations and Joints—special
06/24/2025Maintenance information—energy_progress
06/24/2025HVAC-R and service water piping design and insulation—energy_progress
06/24/2025Energy Code Compliance Inspections—progress
06/24/2025Duct leakage testing, insulation and design—energy_progress
06/24/2025HVAC-R and service water heating equipment—energy_progress
06/24/2025HVAC-R and service water heating system controls—energy_progress
06/23/2025Final—progress
06/23/2025Mechanical Systems—special
02/27/2025Fire-Resistant Penetrations and JointsERIC BERLENTspecial
02/27/2025Fire-Resistant Penetrations and JointsERIC BERLENTspecial
02/27/2025FinalERIC BERLENTprogress
11/15/2024Energy Code Compliance InspectionsAlfred Mierzejewskiprogress
08/14/2024FinalFeng Zhangprogress
08/14/2024Mechanical Systems—special
05/21/2024FinalFeng Zhangprogress
10/16/2021FinalAHMED SHAABANprogress
▾Tenants in the building
TenantSpaceFloorsRenovation projects
T-MobileRetailFloor 1
Project Q01187462 Alteration · LOC Issued · 04/03/2025
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 111 on file (BIS + DOB NOW)
▸Plans & Drawings13
▸DOB NOWPlans/Sketch13
08/27/2026Q00512034-I1Request digital key ↗
08/25/2026Q08016229-I1Request digital key ↗
08/21/2026Q01035286-S1Request digital key ↗
Showing 3 of 13 on file for this type
▸Applications & Permits18
▸DOB NOWLPC Approval/Permit9
08/13/2026Q01213270-I1Open ↗
08/13/2026Q08016229-I1Open ↗
08/13/2026Q01035286-I1Open ↗
Showing 3 of 9 on file for this type
▸BISWORK PERMIT APPLICATION5
01/22/2015440198019Open ↗
01/21/2015440197920Open ↗
10/28/2014421041731Open ↗
Showing 3 of 5 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION4
01/22/2015440198019Open ↗
01/21/2015440197920Open ↗
10/28/2014421041731Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications35
▸DOB NOWDPL-1: Design Professional Seal & Signature13
08/21/2026Q01035286-I1Open ↗
08/21/2026Q01035286-S1Open ↗
08/21/2026Q01035286-S2Open ↗
Showing 3 of 13 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
07/16/2015440197920Open ↗
07/16/2015440198019Open ↗
10/28/2014421041731Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
08/31/2026Q00512034-I1Open ↗
08/28/2026Q01187462-S1Open ↗
08/28/2026Q01187462-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/28/2026Q01187462-S1Open ↗
08/28/2026Q01187462-P2Open ↗
08/27/2026Q01187462-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
01/22/2015440198019Open ↗
01/21/2015440197920Open ↗
10/28/2014421041731Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
01/22/2015440198019Open ↗
01/21/2015440197920Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
01/22/2015440198019Open ↗
01/21/2015440197920Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
10/28/2014421041731Open ↗
▸Trade Schedules & Equipment4
▸BISEQUIPMENT USE PERMITS2
06/20/2013420814248Open ↗
06/20/2013420814248Open ↗
▸BISSIGN HANGER CERTIFICATE1
11/08/2014421041731Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT1
06/19/2013420814248Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE SUPPORTING DOCUMENT1
11/07/2014421041731Open ↗
▸Environmental & Asbestos15
▸DOB NOWDEP ACP-5: Asbestos Assessment Report12
08/21/2026Q01035286-I1Open ↗
08/21/2026Q01035286-S1Open ↗
08/21/2026Q01035286-S2Open ↗
Showing 3 of 12 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)3
01/22/2015440198019Open ↗
10/28/2014421041731Open ↗
02/25/2013420814248Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
06/12/2013420814248Open ↗
05/30/2013420814248Open ↗
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
01/21/2015440197920Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
06/13/2013420814248Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
01/22/2015440198019Open ↗
01/21/2015440197920Open ↗
▸Approvals, Objections & Sign-offs11
▸BISLETTERS - SUPPORTING DOCUMENTATION4
07/21/2015440197920Open ↗
07/21/2015440198019Open ↗
06/19/2013420814248Open ↗
Showing 3 of 4 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
07/21/2015440197920Open ↗
07/21/2015440198019Open ↗
06/19/2013420814248Open ↗
▸BISLANDMARKS APPROVAL3
01/22/2015440198019Open ↗
01/21/2015440197920Open ↗
03/04/2013420814248Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
02/25/2013420814248Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
10/28/2014421041731Open ↗
06/13/2013420814248Open ↗
02/25/2013420814248Open ↗
▸Filing & Intake Forms4
▸BISEFILING JOB APPLICATION COVER SHEET2
01/22/2015440198019Open ↗
01/21/2015440197920Open ↗
▸BISEFILING COVER SHEET2
10/28/2014421041731Open ↗
02/25/2013420814248Open ↗
▸Other Documents1
▸DOB NOWProof of Historic Building1
08/13/2026Q01187462-I1Open ↗