← Back
Zoned commercial or Manhattan residential
37-60 103 STREET
QUEENS · BIN 4044235
💬 Discuss this project
0Year Built
—Stories
V1Building Class
R6BZoning
0 sfGross Floor Area
0Units
3 Open Violations ▸
Zoned commercial or Manhattan residential · 2,593 sf lot · 0 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingCivil
Permit Issued — active, not yet Signed-off
RoofUnder Construction15p · 1 filing · 20 docs
Floor 4Under Construction32p · 2 filings · 20 docs
Floor 3Under Construction36p · 2 filings · 20 docs
Floor 2Under Construction37p · 3 filings · 20 docs
Floor 1Under Construction36p · 2 filings · 20 docs
CellarUnder Construction37p · 2 filings · 20 docs
2 jobs · most recent 08/23/2025
Heating Systems Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/23/2025Permit IssuedEXCELLENT METROPOLITANHeating Systems
Heating
Lg LAN090HSV5 9,000 BTU · Fan Coil Indoor ×8
LMU30CHV 30,000 BTU · Vrf Outdoor ×8
LAN120HSV5 1 tons · Vrf Outdoor ×4
A.O. Smith GCF-40 200 40,000 BTU · Water Heater ×4
05/08/2023——Heating and Air Conditioning Systems, Heating Systems, Ventilation Systems—
2 jobs · most recent 09/18/2026
General Wiring
FiledStatusContractorScope
09/18/2026Permit IssuedKJK ELECTRIC INCGeneral Wiring
08/05/2025CompleteRICHARD NEU—
1 job · most recent 08/23/2025
Steel Concrete Masonry
FiledStatusContractorScope
08/23/2025Permit IssuedEXCELLENT METROPOLITANSteel, Concrete, Masonry
1 job · most recent 05/01/2025
Fence
FiledStatusContractorScope
05/01/2025Permit IssuedEXCELLENT METROPOLITANFence
Building Lifecycle
All (126)Filed (14)Permit Issued (15)Signed Off (1)Violation (7)Inspection (19)Objection (40)Special Inspection (30)
06/02/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
05/26/2026
Permit issued — Mechanical Systems
Q00970764-S3-MS
05/20/2026
Permit issued — Construction Fence
Q01219147-I1-FN
05/20/2026
Permit issued — Structural
Q00970764-S8-ST
05/20/2026
Permit issued — Foundation
Q00970764-S7-FO-EA
05/06/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/07/2026
Permit issued — General Construction
Q00970764-I1-GC
04/01/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/01/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/04/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
03/04/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/20/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
02/17/2026
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
02/17/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/10/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/06/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
02/06/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
01/22/2026
Permit issued — Plumbing
Q31196052-S4-PL
01/09/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/30/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/30/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
12/30/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
12/30/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/30/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
12/24/2025
Permit issued — Plumbing
Q00970764-S4-EW-SP
12/23/2025
Permit issued — Plumbing
Q00970764-S4-PL
11/18/2025
Signed off — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AND PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF 2022 THE NYC BUILDING CODE.LIVE LOAD 300PSF.
Q01261992-I1
09/19/2025
Special inspection requirement — Concrete - Cast-In-Place
XIONGCAI GU
09/19/2025
Special inspection requirement — Insulation placement and R values
XIONGCAI GU
09/19/2025
Special inspection requirement — Interior lighting power
XIONGCAI GU
09/19/2025
Special inspection requirement — Energy Code Compliance Inspections
XIONGCAI GU
09/19/2025
Special inspection requirement — Fire-Resistance Rated Construction
XIONGCAI GU
09/19/2025
Special inspection requirement — Masonry
XIONGCAI GU
09/19/2025
Special inspection requirement — Air barrier - visual inspection
XIONGCAI GU
09/19/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
XIONGCAI GU
09/19/2025
Special inspection requirement — Lighting in dwelling units
XIONGCAI GU
09/19/2025
Special inspection requirement — Protection of exposed foundation insulation
XIONGCAI GU
09/19/2025
Special inspection requirement — Fenestration air leakage
XIONGCAI GU
09/19/2025
Special inspection requirement — Metering
XIONGCAI GU
09/19/2025
Special inspection requirement — Maintenance information
XIONGCAI GU
09/19/2025
Special inspection requirement — Air barrier — testing
XIONGCAI GU
09/19/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIONGCAI GU
09/19/2025
Special inspection requirement — Lighting controls
XIONGCAI GU
09/19/2025
Special inspection requirement — Exterior lighting power
XIONGCAI GU
09/19/2025
Special inspection requirement — Fenestration areas
XIONGCAI GU
09/17/2025
Violation issued (ECB, open)
Construction
08/23/2025
Filed — New Building
INSTALL FOUNDATION AND EARTHWORK IN CONJUNCTION WITH JOB#Q00970764
Q00970764-P4
08/13/2025
Special inspection requirement — Insulation placement and R values
XIONGCAI GU
08/13/2025
Special inspection requirement — Exterior lighting power
XIONGCAI GU
08/13/2025
Special inspection requirement — Air barrier — testing
XIONGCAI GU
08/13/2025
Special inspection requirement — Lighting controls
XIONGCAI GU
08/13/2025
Special inspection requirement — Fenestration areas
XIONGCAI GU
08/13/2025
Special inspection requirement — Fenestration air leakage
XIONGCAI GU
08/13/2025
Special inspection requirement — Masonry
XIONGCAI GU
08/13/2025
Special inspection requirement — Fire-Resistance Rated Construction
XIONGCAI GU
08/13/2025
Special inspection requirement — Concrete - Cast-In-Place
XIONGCAI GU
08/13/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIONGCAI GU
08/13/2025
Special inspection requirement — Energy Code Compliance Inspections
XIONGCAI GU
08/13/2025
Special inspection requirement — Lighting in dwelling units
XIONGCAI GU
08/06/2025
Violation issued (ECB, open)
Unknown
Latest 60 of 126 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PLATINUM SERVICES NY504/09/2026
JCNY DEVELOPMENT GR203/22/2026
37-13 REALTY INC CHOI YUI103/22/2026
RISE UP REALTY403/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/27/2022$1.3M—37-13 REALTY INC. → Private party— not available
10/16/2015$1.1M—— → —— not available
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AMERILAND BROOK LLC1108/23/2025
ASHRAF CORP107/30/2025
BRIAN ILL DEVELOPMENT LLC105/01/2025
JIMENEZ BUILDING CONSULTING LLC105/08/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AMERILAND BROOK LLC803/21/2026
SD DESIGN STUDIO203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
EXCELLENT METROPOLITANGeneral Contractor1407/08/2026
WATSON'S PLBG, HTG, & BDGPlumbing707/08/2026
JUST PLBG & HTG INCPlumbing607/08/2026
PLATINUM SERVICES NY LLCGeneral Contractor204/09/2026
NEU, RICHARDElectrical103/21/2026
RICHARD NEUElectrical103/21/2026
FOY, REMERElectrical103/21/2026
RRP PLUMBING CORPFire Protection107/08/2026
SERGIO GIANNACHIElectrical103/21/2026
H&F IRON WORKSElectrical103/21/2026
KJK ELECTRIC INCElectrical103/22/2026
LELIS, ARILSONElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
G ENGINEERING PC7778808/23/2025
BUILDING CONSULTING ENGIN1034102/17/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedEXCELLENT METROPOLITAN05/26/2026
DOB NOWConstruction FencePermit IssuedEXCELLENT METROPOLITAN05/20/2026
DOB NOWStructuralPermit IssuedEXCELLENT METROPOLITAN05/20/2026
DOB NOWFoundationPermit IssuedEXCELLENT METROPOLITAN05/20/2026
DOB NOWGeneral ConstructionPermit IssuedEXCELLENT METROPOLITAN04/07/2026
DOB NOWPlumbingPermit IssuedMOHAMED ABDELRAZEK01/22/2026
DOB NOWPlumbingPermit IssuedRALPH W. LANDOLFI JR.12/24/2025
DOB NOWPlumbingPermit IssuedWATSON'S PLBG, HTG, & BDG12/23/2025
DOB NOWSupported ScaffoldSigned-offPLATINUM SERVICES NY LLC07/30/2025
DOB NOWSidewalk ShedSigned-offPLATINUM SERVICES NY LLC07/30/2025
DOB NOWEarth WorkPermit IssuedEXCELLENT METROPOLITAN05/12/2025
DOB NOWGeneral ConstructionPermit IssuedEXCELLENT METROPOLITAN05/12/2025
DOB NOWStructuralPermit IssuedEXCELLENT METROPOLITAN05/12/2025
DOB NOWSupport of ExcavationPermit IssuedEXCELLENT METROPOLITAN05/12/2025
DOB NOWConstruction FencePermit IssuedEXCELLENT METROPOLITAN05/08/2025
BISEQISSUEDPEERLESS BUILDERS INC04/14/2022
BIS—ISSUEDJCNY DEVELOPMENT GR INC10/18/2018
BISEQRE-ISSUEDJCNY DEVELOPMENT GR INC10/18/2018
BIS—ISSUEDJCNY DEVELOPMENT GR INC10/18/2018
BISEQISSUEDFIRST CLASS MANAGEMENT CO01/26/2017
BIS—ISSUEDFIRST CLASS MANAGEMENT CO01/26/2017
▾Field Inspections (DOB CAP) — 19
DateTypeResultReport
06/02/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
05/06/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/01/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/01/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/04/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
03/04/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/20/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
02/17/2026Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
02/17/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/10/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/06/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
02/06/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
01/09/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/30/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/30/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
12/30/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
12/30/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/30/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
06/04/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
09/19/2025MasonryXIONGCAI GUspecial
09/19/2025Fenestration air leakageXIONGCAI GUenergy_progress
09/19/2025Fenestration and door U-factor and product ratingsXIONGCAI GUenergy_progress
09/19/2025Lighting in dwelling unitsXIONGCAI GUenergy_progress
09/19/2025Protection of exposed foundation insulationXIONGCAI GUenergy_progress
09/19/2025Maintenance informationXIONGCAI GUenergy_progress
09/19/2025Air barrier — testing XIONGCAI GUenergy_progress
09/19/2025Insulation placement and R valuesXIONGCAI GUenergy_progress
09/19/2025Fenestration areasXIONGCAI GUenergy_progress
09/19/2025Exterior lighting powerXIONGCAI GUenergy_progress
09/19/2025Lighting controlsXIONGCAI GUenergy_progress
09/19/2025MeteringXIONGCAI GUenergy_progress
09/19/2025Interior lighting powerXIONGCAI GUenergy_progress
09/19/2025Air barrier - visual inspectionXIONGCAI GUenergy_progress
09/19/2025Energy Code Compliance InspectionsXIONGCAI GUprogress
09/19/2025Fire-Resistance Rated ConstructionXIONGCAI GUprogress
09/19/2025Concrete - Cast-In-PlaceXIONGCAI GUspecial
09/19/2025Fire-Resistant Penetrations and JointsXIONGCAI GUspecial
08/13/2025Concrete - Cast-In-PlaceXIONGCAI GUspecial
08/13/2025Protection of exposed foundation insulationXIONGCAI GUenergy_progress
08/13/2025Maintenance informationXIONGCAI GUenergy_progress
08/13/2025MeteringXIONGCAI GUenergy_progress
08/13/2025Air barrier - visual inspectionXIONGCAI GUenergy_progress
08/13/2025Interior lighting powerXIONGCAI GUenergy_progress
08/13/2025Fenestration and door U-factor and product ratingsXIONGCAI GUenergy_progress
Latest 25 of 150.
▾Documents — 259 on file (BIS + DOB NOW)
▸Plans & Drawings14
▸DOB NOWPlans/Sketch14
08/24/2026Q00870472-I1Request digital key ↗
08/23/2026Q00970764-I1Request digital key ↗
08/23/2026Q00970764-S1Request digital key ↗
Showing 3 of 14 on file for this type
▸Applications & Permits35
▸BISPLAN / WORK APPROVAL APPLICATION27
08/19/2024440709592Open ↗
05/04/2023421238057Open ↗
05/02/2023421238057Open ↗
Showing 3 of 27 on file for this type
▸BISWORK PERMIT APPLICATION6
04/29/2022421238057Open ↗
11/13/2018421238057Open ↗
11/13/2018421238057Open ↗
Showing 3 of 6 on file for this type
▸BISBPP-5 - Authorization to the Department of Transportation2
04/02/2022440709592Open ↗
05/10/2016421322517Open ↗
▸Zoning, Tax Lot & Property Records14
▸DOB NOWZD1: DOB Zoning Diagram4
08/13/2026Q00870472-I1Open ↗
08/13/2026Q00970764-P4Open ↗
08/13/2026Q00970764-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWZoning Exhibit form (1-5)4
08/13/2026Q00970764-P4Open ↗
08/13/2026Q00970764-I1Open ↗
08/13/2026Q00870472-I1Open ↗
Showing 3 of 4 on file for this type
▸BISZONING DIAGRAM3
04/13/2022440661204Open ↗
10/26/2016421238057Open ↗
06/06/2016421238057Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
04/08/2022440661204Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
04/08/2022440661204Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00970764-I1Open ↗
▸Seals & Professional Certifications114
▸DOB NOWProgress Inspector Seal & Signature68
09/12/2026Q00970764-S8Open ↗
08/29/2026Q00970764-S4Open ↗
08/29/2026Q00970764-S4Open ↗
Showing 3 of 68 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature23
09/12/2026Q00970764-S8Open ↗
09/12/2026Q00970764-S8Open ↗
08/29/2026Q00970764-S4Open ↗
Showing 3 of 23 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature14
08/23/2026Q00970764-I1Open ↗
08/23/2026Q00970764-S1Open ↗
08/23/2026Q00970764-S3Open ↗
Showing 3 of 14 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
11/13/2018421238057Open ↗
11/13/2018421238057Open ↗
10/25/2016421238057Open ↗
Showing 3 of 5 on file for this type
▸BISAPPLICANT OWNER SIGNATURE3
04/02/2022440709592Open ↗
02/01/2021440661204Open ↗
02/01/2021440661204Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
04/02/2022440709592Open ↗
▸Trade Schedules & Equipment7
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)3
08/13/2026Q00970764-P2Open ↗
08/13/2026Q00970764-I1Open ↗
08/13/2026Q00970764-P4Open ↗
▸BISELECTRIC CUT-OFF1
01/27/2017421351370Open ↗
▸BISGAS CUT-OFF1
01/27/2017421351370Open ↗
▸BISSEWER CUT-OFF1
01/27/2017421351370Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
09/30/2016421238057Open ↗
▸Safety & Tenant Protection12
▸BISSTREET TREE CHECKLIST4
07/23/2021440661204Open ↗
07/24/2017421322517Open ↗
10/25/2016421238057Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWStreet Tree Checklist4
08/13/2026Q00870472-I1Open ↗
08/13/2026Q00970764-P2Open ↗
08/13/2026Q00970764-I1Open ↗
Showing 3 of 4 on file for this type
▸BISEXCAVATION OR DEMOLITION: 5-DAY NOTICE2
01/27/2017421351370Open ↗
01/27/2017421351370Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026Q00970764-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00970764-I1Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
01/27/2017421351370Open ↗
▸BISRODENT CONTROL1
01/27/2017421351370Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
11/13/2018421238057Open ↗
11/13/2018421238057Open ↗
06/06/2016421238057Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
07/23/2021440661204Open ↗
▸Inspections & Test Reports7
▸BISTECHNICAL REPORT: RESPONSIBILITY2
07/23/2021440661204Open ↗
07/23/2021440661204Open ↗
▸BISSOIL REPORT1
07/23/2021440661204Open ↗
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER1
11/13/2018421238057Open ↗
▸BISTECHNICAL REPORT: SOIL INSPECTION1
10/25/2016421238057Open ↗
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX1
11/13/2018421238057Open ↗
▸BISSUBSURFACE / SOILS INVESTIGATION (BORINGS/TEST PITS)1
07/23/2021440661204Open ↗
▸Approvals, Objections & Sign-offs17
▸BISSCHEDULE A - OCCUPANCY / USE10
05/02/2023421238057Open ↗
03/24/2023421238057Open ↗
03/20/2023421238057Open ↗
Showing 3 of 10 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION4
01/27/2017421351370Open ↗
01/27/2017421351370Open ↗
12/30/2016421351370Open ↗
Showing 3 of 4 on file for this type
▸BISADMINISTRATIVE OBJECTIONS1
01/04/2016421238057Open ↗
▸BISSUPERSEDING LETTER1
04/29/2022421238057Open ↗
▸BISTAP LETTER - DOM SVC : DEP-DOM1
01/27/2017421351370Open ↗
▸Cost, Insurance & Ownership1
▸BISPROJECT-SPECIFIC GL INSURANCE1
11/13/2018421238057Open ↗
▸Filing & Intake Forms13
▸BISEFILING COVER SHEET5
09/30/2016421238057Open ↗
09/29/2016421238057Open ↗
08/15/2016421351370Open ↗
Showing 3 of 5 on file for this type
▸BISADDITIONAL INFORMATION3
04/13/2022440661204Open ↗
07/23/2021440661204Open ↗
07/23/2021440661204Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT32
04/02/2022440709592Open ↗
07/24/2017421322517Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET2
04/02/2022440709592Open ↗
02/01/2021440661204Open ↗
▸BISSRO INTAKE FORM(SRO1)1
01/27/2017421351370Open ↗
▸Other Documents19
▸DOB NOWSite Survey: Initial4
08/13/2026Q00870472-I1Open ↗
08/13/2026Q00970764-P2Open ↗
08/13/2026Q00970764-P4Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
08/13/2026Q00970764-I1Open ↗
08/13/2026Q00870472-I1Open ↗
08/13/2026Q00970764-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProperty Ownership Certification4
08/23/2026Q00970764-I1Open ↗
08/23/2026Q00970764-P2Open ↗
08/23/2026Q00970764-P4Open ↗
Showing 3 of 4 on file for this type
▸BISBPP - SUPPORTING DOCUMENTATION2
11/14/2018421238057Open ↗
11/13/2018421238057Open ↗
▸DOB NOWAdjoining Owners Notification2
08/13/2026Q00970764-S6Open ↗
08/13/2026Q00970764-S7Open ↗
▸BISSITE CONNECTION:DEP1
10/25/2016421238057Open ↗
▸BISSUSTAINABLE ROOF ZONE FORM1
02/01/2021440661204Open ↗
▸BISPLOT DIAGRAM1
01/22/2016421238057Open ↗