← Back
Five to six families
37 DECATUR STREET
BROOKLYN · BIN 3053540
💬 Discuss this project
1887Year Built
4Stories
C2Building Class
R6BZoning
3,375 sfGross Floor Area
6Units
Rent Stabilized2 Open Violations 1 unresolved · 1 paperwork only ▸FDNY Report ↗
Five to six families · Owner of record: 37 BOLT EQUITIES LLC · 1,875 sf lot · 1.8 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
RoofUnder Construction21p · 1 filing · 20 docs
Floor 3Under Construction20p · 2 filings · 20 docs
Floor 2Under Construction20p · 2 filings · 20 docs
Floor 1Under Construction20p · 2 filings · 20 docs
CellarUnder Construction23p · 2 filings · 20 docs
BasementUnder Construction20p · 1 filing · 20 docs
Sub-BasementUnder Construction1 filing · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BRICKSTONE GROUP1609/08/2026
ACE GROUP NY CORP.503/22/2026
37 BOLT EQUITIES LLC203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/19/2025$1.7M—— → —$490/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CQ&J CORPORATION907/23/2026
BANGASH ASSOCIATES INC.109/18/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
WM ARCH1203/21/2026
GREEN STUDIO203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
YAFE MEOD CORPGeneral Contractor407/08/2026
ACE GROUP NY CORPGeneral Contractor303/21/2026
BRUCHE MECHANICAL NY LLCFire Protection107/08/2026
BLUEBUILD MGMT INCGeneral Contractor104/09/2026
PLBG P & H INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SIMON7555507/23/2026
Building Lifecycle
All (141)Filed (10)Permit Issued (8)Signed Off (2)Violation (60)Inspection (11)Objection (20)Special Inspection (30)
08/06/2026
Objection resolved — Resolved
08/03/2026
Objection raised — Other
07/28/2026
Special inspection requirement — Energy Code Compliance Inspections
CALVIN TRAN
07/28/2026
Special inspection requirement — HVAC-R and service water heating system controls
CALVIN TRAN
07/28/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
CALVIN TRAN
07/28/2026
Special inspection requirement — HVAC-R and service water heating equipment
CALVIN TRAN
07/28/2026
Special inspection requirement — Mechanical Systems
SIMON JIANG
07/28/2026
Special inspection requirement — Final
CALVIN TRAN
07/28/2026
Special inspection requirement — Energy Code Compliance Inspections
CALVIN TRAN
07/28/2026
Special inspection requirement — Shutoff dampers
CALVIN TRAN
07/28/2026
Special inspection requirement — HVAC-R and service water heating system controls
CALVIN TRAN
07/28/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
CALVIN TRAN
07/28/2026
Special inspection requirement — HVAC-R and service water heating equipment
CALVIN TRAN
07/28/2026
Special inspection requirement — Maintenance information
CALVIN TRAN
07/28/2026
Special inspection requirement — Ventilation and air distribution system
CALVIN TRAN
07/23/2026
Filed — Alteration CO
PROVIDE NEW FIRE SPRINKLER SYSTEM THROUGHOUT 3-STORY WITH BASEMENT & CELLAR RESIDENTIAL BUILDING IN CONJUNCTION WITH ALT1 JOB# B01196091-I1.
B01196091-P5
07/23/2026
Filed — Alteration CO
PROVIDE NEW FIRE SPRINKLER SYSTEM THROUGHOUT 3-STORY WITH BASEMENT & CELLAR RESIDENTIAL BUILDING IN CONJUNCTION WITH ALT1 JOB# B01196091-I1.
B01196091-P4
07/22/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
CALVIN TRAN
07/22/2026
Special inspection requirement — Energy Code Compliance Inspections
CALVIN TRAN
07/22/2026
Special inspection requirement — Final
CALVIN TRAN
07/22/2026
Special inspection requirement — HVAC-R and service water heating equipment
CALVIN TRAN
07/22/2026
Special inspection requirement — Maintenance information
CALVIN TRAN
07/22/2026
Special inspection requirement — Ventilation and air distribution system
CALVIN TRAN
07/22/2026
Special inspection requirement — Shutoff dampers
CALVIN TRAN
07/22/2026
Special inspection requirement — HVAC-R and service water heating system controls
CALVIN TRAN
07/22/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
CALVIN TRAN
07/22/2026
Special inspection requirement — Energy Code Compliance Inspections
CALVIN TRAN
07/22/2026
Special inspection requirement — Mechanical Systems
SIMON JIANG
07/22/2026
Special inspection requirement — HVAC-R and service water heating equipment
CALVIN TRAN
07/22/2026
Special inspection requirement — HVAC-R and service water heating system controls
CALVIN TRAN
07/16/2026
Objection resolved — Addressed
07/06/2026
Objection raised — Other
06/16/2026
Signed off — Alteration
INSTALL TEMPORARY CONSTRUCTION FENCE FOR WITH INTERIOR RENOVATIONS UNDER ALT-CO JOB # B01189675-I1.
B01196046-I1
06/14/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
06/04/2026
Filed — Alteration CO
PROVIDE NEW FIRE SPRINKLER SYSTEM THROUGHOUT 3-STORY WITH BASEMENT & CELLAR RESIDENTIAL BUILDING IN CONJUNCTION WITH ALT1 JOB# B01196091-I1.
B01196091-P2
06/04/2026
Special inspection requirement — Maintenance information
CALVIN TRAN
06/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SIMON JIANG
06/04/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
SIMON JIANG
06/04/2026
Special inspection requirement — Energy Code Compliance Inspections
CALVIN TRAN
05/20/2026
Permit issued — Structural
B01196091-I1-GC-CX
05/04/2026
Violation issued (HPD, closed)
A
03/18/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
03/18/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/18/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
02/11/2026
Signed off — Alteration
INSTALLATION OF PIPE SCAFFOLDING PER PLANS. PIPE SCAFFOLDING SHALL COMPLY WITH CHAPTER #33 OF THE 2022 CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01289760-I1
12/03/2025
Permit issued — Mechanical Systems
B01196091-S3-MS
11/13/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/13/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/13/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/06/2025
Inspection — Pass-Final PL - More than 10 Requested Floors
Pass
View inspection ↗
10/28/2025
Filed — Alteration CO
PROVIDE NEW FIRE SPRINKLER SYSTEM THROUGHOUT 3-STORY WITH BASEMENT & CELLAR RESIDENTIAL BUILDING IN CONJUNCTION WITH ALT1 JOB# B01196091-I1.
B01196091-S3
09/30/2025
Permit issued — Plumbing
B01196091-S1-PL
09/30/2025
Permit issued — Sprinklers
B01196091-S2-EW-SP
09/29/2025
Permit issued — Structural
B01196091-I1-GC-CX
09/26/2025
Filed — Alteration CO
PROVIDE NEW FIRE SPRINKLER SYSTEM THROUGHOUT 3-STORY WITH BASEMENT & CELLAR RESIDENTIAL BUILDING IN CONJUNCTION WITH ALT1 JOB# B01196091-I1.
B01196091-S1
09/26/2025
Filed — Alteration CO
PROVIDE NEW FIRE SPRINKLER SYSTEM THROUGHOUT 3-STORY WITH BASEMENT & CELLAR RESIDENTIAL BUILDING IN CONJUNCTION WITH ALT1 JOB# B01196091-I1.
B01196091-S2
09/19/2025
Permit issued — Supported Scaffold
B01289760-I1-SF
09/18/2025
Filed — Alteration
INSTALLATION OF PIPE SCAFFOLDING PER PLANS. PIPE SCAFFOLDING SHALL COMPLY WITH CHAPTER #33 OF THE 2022 CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01289760-I1
08/29/2025
Objection resolved — Addressed
06/27/2025
Objection resolved — Addressed
Latest 60 of 141 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedYAFE MEOD CORP05/20/2026
DOB NOWMechanical SystemsPermit IssuedYAFE MEOD CORP12/03/2025
DOB NOWPlumbingPermit IssuedPLBG P & H INC09/30/2025
DOB NOWSprinklersPermit IssuedBRUCHE MECHANICAL NY LLC09/30/2025
DOB NOWStructuralPermit IssuedYAFE MEOD CORP09/29/2025
DOB NOWSupported ScaffoldSigned-offACE GROUP NY CORP09/19/2025
DOB NOWConstruction FenceSigned-offBLUEBUILD MGMT INC04/08/2025
DOB NOWGeneral ConstructionPermit IssuedYAFE MEOD CORP03/14/2025
1 project · most recent 07/23/2026
Air Conditioning Systems Heating and Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/23/2026Permit IssuedYAFE MEOD CORPAir Conditioning Systems, Heating and Air Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Daikin FTXS09WVJU9 10,900 BTU · Fan Coil Indoor ×15
FTXC09AXVJU 9,400 BTU · Fan Coil Indoor ×5
Heat / Cool
Daikin 4MXL36WVJU9 36,000 BTU · Condensing Unit ×14
3MXL24WMVJU9 24,000 BTU · Condensing Unit ×5
RXC09AXVJU 9,000 BTU · Condensing Unit ×5
Heating
Daikin FDMQ18WVJU9 21,600 BTU · Vrf Indoor ×14
FDMQ24WVJU9 24,000 BTU · Vrf Indoor ×9
FDMQ15WVJU9 18,000 BTU · Fan Coil Indoor ×5
Ventilation
Greenheck SP-B150 100 CFM · Exhaust Fan ×5
SP-BA110 50 CFM · Exhaust Fan ×5
1 project · most recent 07/23/2026
Sprinkler System
FiledStatusContractorScope
07/23/2026Permit IssuedPLBG P & H INCSprinkler System
1 project · most recent 07/23/2026
Gas Water/Sanitary
FiledStatusContractorScope
07/23/2026Permit IssuedPLBG P & H INCGas, Water/Sanitary
1 project · most recent 08/06/2026
General Wiring
FiledStatusContractorScope
08/06/2026CompleteSolar Pro Electric Inc.General Wiring
1 project · most recent 07/23/2026
FiledStatusContractorScope
07/23/2026Permit IssuedYAFE MEOD CORP2 scope_items
1 project · most recent 03/31/2025
Fence
FiledStatusContractorScope
03/31/2025Signed-offBLUEBUILD MGMT INCFence
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
06/14/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
03/18/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/18/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/18/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
11/13/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/13/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/13/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
11/06/2025Pass-Final PL - More than 10 Requested FloorsPassView ↗
11/05/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/29/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/29/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 44
DateRequirementInspectorRole
07/28/2026Energy Code Compliance InspectionsCALVIN TRANprogress
07/28/2026HVAC-R and service water heating system controlsCALVIN TRANenergy_progress
07/28/2026HVAC-R and service water piping design and insulationCALVIN TRANenergy_progress
07/28/2026HVAC-R and service water heating equipmentCALVIN TRANenergy_progress
07/28/2026Mechanical SystemsSIMON JIANGspecial
07/28/2026FinalCALVIN TRANprogress
07/28/2026Energy Code Compliance InspectionsCALVIN TRANprogress
07/28/2026Shutoff dampersCALVIN TRANenergy_progress
07/28/2026HVAC-R and service water heating system controlsCALVIN TRANenergy_progress
07/28/2026HVAC-R and service water piping design and insulationCALVIN TRANenergy_progress
07/28/2026HVAC-R and service water heating equipmentCALVIN TRANenergy_progress
07/28/2026Maintenance informationCALVIN TRANenergy_progress
07/28/2026Ventilation and air distribution systemCALVIN TRANenergy_progress
07/22/2026HVAC-R and service water piping design and insulationCALVIN TRANenergy_progress
07/22/2026Energy Code Compliance InspectionsCALVIN TRANprogress
07/22/2026FinalCALVIN TRANprogress
07/22/2026HVAC-R and service water heating equipmentCALVIN TRANenergy_progress
07/22/2026Maintenance informationCALVIN TRANenergy_progress
07/22/2026Ventilation and air distribution systemCALVIN TRANenergy_progress
07/22/2026Shutoff dampersCALVIN TRANenergy_progress
07/22/2026HVAC-R and service water heating system controlsCALVIN TRANenergy_progress
07/22/2026HVAC-R and service water piping design and insulationCALVIN TRANenergy_progress
07/22/2026Energy Code Compliance InspectionsCALVIN TRANprogress
07/22/2026Mechanical SystemsSIMON JIANGspecial
07/22/2026HVAC-R and service water heating equipmentCALVIN TRANenergy_progress
Latest 25 of 44.
▾Documents — 84 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
08/22/2026B01189675-I1Request digital key ↗
08/22/2026B01196046-I1Request digital key ↗
08/20/2026B01289760-I1Request digital key ↗
Showing 3 of 11 on file for this type
▸Applications & Permits7
▸DOB NOWLPC Approval/Permit7
08/16/2026B01196091-P4Open ↗
08/16/2026B01196091-P5Open ↗
08/15/2026B01196091-I1Open ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/15/2026B01196091-I1Open ↗
08/15/2026B01196091-P2Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/15/2026B01196091-I1Open ↗
08/15/2026B01196091-P2Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/15/2026B01196091-I1Open ↗
▸Seals & Professional Certifications31
▸DOB NOWProgress Inspector Seal & Signature15
08/28/2026B01196091-S1Open ↗
08/28/2026B01196091-S1Open ↗
08/28/2026B01196091-S1Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/16/2026B01196091-P5Open ↗
08/16/2026B01196091-P4Open ↗
08/16/2026B01196091-P2Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/01/2026B01196091-S2Open ↗
08/28/2026B01196091-P2Open ↗
08/28/2026B01196091-P2Open ↗
Showing 3 of 5 on file for this type
▸Safety & Tenant Protection13
▸DOB NOWHPD-3: Single Room Occupancy Multiple Dwelling (SRO MD) Anti-Harassment Checklist11
08/16/2026B01196091-P5Open ↗
08/16/2026B01196091-P4Open ↗
08/16/2026B01196091-P3Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWStreet Tree Checklist2
08/15/2026B01196091-I1Open ↗
08/15/2026B01196091-P2Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/16/2026B01196091-P5Open ↗
08/16/2026B01196091-P4Open ↗
08/16/2026B01196091-S3Open ↗
Showing 3 of 9 on file for this type
▸Other Documents8
▸DOB NOWSite Survey: Initial2
08/15/2026B01196091-I1Open ↗
08/15/2026B01196091-P2Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/15/2026B01196091-I1Open ↗
08/15/2026B01196091-P2Open ↗
▸DOB NOWPlot Diagram2
08/15/2026B01196091-I1Open ↗
08/15/2026B01196091-P2Open ↗
▸DOB NOWProperty Ownership Certification2
08/15/2026B01196091-I1Open ↗
08/15/2026B01196091-P2Open ↗