← Back
BuildNYC
Three families
373 DOUGLASS STREET
BROOKLYN · Park Slope · BIN 3019179
💬 Discuss this project
1910Year Built
3Stories
C0Building Class
R6BZoning
2,700 sfGross Floor Area
3Units
Rent Stabilized0 Active ViolationsFDNY Report ↗
Three families · 2,000 sf lot · 1.35 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
RoofPorous concrete pavers to drywellUnder Construction36p · 1 filing · 20 docs
Floor 3Porous concrete pavers to drywellUnder Construction34p · 1 filing · 20 docs
Floor 2Porous concrete pavers to drywellUnder Construction33p · 1 filing · 20 docs
Floor 1Porous concrete pavers to drywellUnder Construction32p · 1 filing · 20 docs
CellarPorous concrete pavers to drywellUnder Construction35p · 1 filing · 20 docs
Site & exteriorPorous concrete pavers to drywellUnder Construction30p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
John H Hatheway Jr., Architect406/19/2024
None606/14/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Brooklyn Root Design1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Woodpoint Construction SEGeneral Contractor507/08/2026
Accrete Construction GroupGeneral Contractor303/21/2026
EJ Homes 45General Contractor304/09/2026
AL-Lectric Elect'l ContractingElectrical103/22/2026
Accrete Construction GroupPlumbing104/09/2026
Rock E Small Plumbing & HeatingPlumbing108/25/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
John H Hatheway Jr4175406/19/2024
Just Consulting Engineering5865906/14/2024
Building Lifecycle
10/03/2026
Permit expired, never signed off — General Construction
The city's record still shows this permit as issued, with no sign-off on its filing
B08012991-I1-GC
08/24/2026
Permit issued — Plumbing
B08012991-S1-PL
11/11/2025
Signed off — Alteration
Propose foundation work type in conjunction with GC application number B08012991-I1.
B08012991-S4
11/10/2025
Signed off — Alteration
Propose foundation work type in conjunction with GC application number B08012991-I1.
B08012991-S2
11/10/2025
Permit renewed — Support of Excavation
Renewed with changes
B08012991-S4-SE
99 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedRock E Small Plumbing & Heating08/24/2026
DOB NOWSupport of ExcavationSigned-offEJ Homes 4511/10/2025
DOB NOWFoundationSigned-offEJ Homes 4511/07/2025
DOB NOWGeneral ConstructionPermit IssuedWoodpoint Construction SE10/14/2025
DOB NOWGeneral ConstructionPermit IssuedWoodpoint Construction SE10/07/2024
DOB NOWStructuralSigned-offWoodpoint Construction SE10/03/2024
DOB NOWStructuralSigned-offWoodpoint Construction SE06/03/2024
DOB NOWGeneral ConstructionPermit IssuedWoodpoint Construction SE12/29/2023
DOB NOWSupport of ExcavationSigned-offAccrete Construction Group10/18/2023
1 project · most recent 06/19/2024
Gas Storm Water/Sanitary
FiledStatusContractorScope
06/19/2024Permit IssuedRock E Small Plumbing & HeatingGas, Storm, Water/Sanitary
1 project · most recent 08/06/2025
General Wiring
FiledStatusContractorScope
08/06/2025Permit IssuedAL-Lectric Elect'l ContractingGeneral Wiring
1 project · most recent 06/19/2024
Steel Concrete Masonry
FiledStatusContractorScope
06/19/2024Permit IssuedRock E Small Plumbing & HeatingSteel, Concrete, Masonry
▾Special Inspection Requirements (DOB NOW) — 69
DateRequirementInspectorRole
01/16/2025Fire-Resistant Penetrations and JointsJohn Hathewayspecial
01/16/2025Lighting in dwelling unitsJohn Hathewayenergy_progress
01/16/2025Fenestration areasJohn Hathewayenergy_progress
01/16/2025Air barrier - visual inspectionJohn Hathewayenergy_progress
01/16/2025Fire-Resistance Rated ConstructionJohn Hathewayprogress
01/16/2025FinalJohn Hathewayprogress
01/16/2025Energy Code Compliance InspectionsJohn Hathewayprogress
01/16/2025Subgrade InspectionsXIAOJUN WANGspecial
01/16/2025Structural Stability – Alterations of existing buildingsXIAOJUN WANGspecial
01/16/2025MasonryJohn Hathewayspecial
01/16/2025Concrete - Cast-In-PlaceJohn Hathewayspecial
01/16/2025Fenestration and door U-factor and product ratingsJohn Hathewayenergy_progress
01/16/2025Insulation placement and R valuesJohn Hathewayenergy_progress
01/16/2025Protection of exposed foundation insulationJohn Hathewayenergy_progress
01/16/2025Fenestration air leakageJohn Hathewayenergy_progress
01/16/2025Lighting controlsJohn Hathewayenergy_progress
07/23/2024HVAC-R and service water heating equipmentJohn Hathewayenergy_progress
07/23/2024Maintenance informationJohn Hathewayenergy_progress
07/23/2024HVAC-R and service water piping design and insulationJohn Hathewayenergy_progress
06/28/2024UnderpinningXIAOJUN WANGspecial
06/28/2024Subsurface Investigations (Borings/Test Pits)JONATHAN BILOWspecial
06/28/2024Footing and FoundationXIAOJUN WANGprogress
06/28/2024Post-installed AnchorsXIAOJUN WANGspecial
06/28/2024Subgrade InspectionsXIAOJUN WANGspecial
06/28/2024FinalNathaniel Berganprogress
Latest 25 of 69.
111 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account