← Back
Two family frame
3734 LAUREL AVENUE
BROOKLYN · BIN 3188369
💬 Discuss this project
1935Year Built
2.5Stories
B2Building Class
R3-1Zoning
3,168 sfGross Floor Area
2Units
2 Open Violations 1 unresolved · 1 paperwork only ▸FDNY Report ↗
Two family frame · 4,000 sf lot · 0.79 FAR built · Flood zone X500
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CITISCAPE CONSULTING LTD903/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/20/2021$770K—— → —$243/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CONSULTING ENGINEER207/07/2022
CITISCAPE CONSULTING LTD102/16/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CITISCAPE CONSULTING LTD603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RITE WAY HEATING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CITISCAPE CONSULTING LTD762307/07/2022
Building Lifecycle
All (16)Filed (3)Permit Issued (1)Signed Off (1)Violation (3)Inspection (2)Objection (4)Special Inspection (2)
01/25/2024
Violation issued (ECB, open)
Construction
10/20/2023
Signed off — Alteration
New plumbing application. All indicated plumbing fixtures are new and to be replaced on new roughing
B00717204-I1
10/05/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/07/2022
Filed — Alteration
New plumbing application. All indicated plumbing fixtures are new and to be replaced on new roughing
B00717204-P1
07/07/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Joe Lieberman
07/07/2022
Special inspection requirement — Energy Code Compliance Inspections
Joe Lieberman
07/05/2022
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
06/28/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/25/2022
Permit issued — Plumbing
B00717204-I1-PL
04/14/2022
Filed — Alteration
New plumbing application. All indicated plumbing fixtures are new and to be replaced on new roughing
B00717204-I1
02/24/2022
Objection raised — Other
02/24/2022
Objection resolved — Addressed
02/24/2022
Objection raised — Inspections
02/24/2022
Objection resolved — Addressed
02/16/2022
Filed — Alteration
MECHANICAL APPLICATION IN CONJUNCTION WITH PLUMBING APPLICATION # B00659570
B00677733-I1
04/05/2005
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offLS PLUMBING CORP05/25/2022
1 project · most recent 02/16/2022
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
02/16/2022——Ventilation Systems
Ventilation
N/A NCB-240/130H Boiler ×2
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
07/05/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
06/28/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
07/07/2022Fire-Resistant Penetrations and JointsJoe Liebermanspecial
07/07/2022Energy Code Compliance InspectionsJoe Liebermanprogress
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/29/2026B00717204-I1Request digital key ↗
08/29/2026B00717204-P1Request digital key ↗
08/15/2026B00677733-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/29/2026B00717204-P1Open ↗
08/29/2026B00717204-I1Open ↗
08/13/2026B00677733-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/26/2026B00717204-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026B00717204-P1Open ↗