ECB04/08/2026Reissue on ECB #35717497K. Failure to maintain building in code-compliant manner. Noted: spalling concrete on underside of emergency exterior exit doorway overhang on exits 5, exit 4 and exit 2, observed upon iNothing owed — awaiting certificate of correction
ECB04/08/2026Reissue on ECB #35717494P. Exit door not self-closing. Noted: emergency exterior exit doors not self-closing due to binding, missing or faulty hardware on exterior door exit 2 (3)doors 1ST floor, exit 6 (2)doorNothing owed — awaiting certificate of correction
ECB04/08/2026Reissue on ECB #35719946X. Failure to maintain building in code-compliant manner. Noted: fire rated classroom and smoke doors not self-closing due to binding missing or faulty hardware on smoke doors at main enNothing owed — awaiting certificate of correction
ECB04/08/2026Reissue on ECB #35717498M. Failure to maintain building in code-compliant manner. Noted: perimeter stone knee wall around the whole school with missing, loose and cracked stone in various locations observed upoNothing owed — awaiting certificate of correction
ECB04/08/2026Reissue on ECB #35717495R. Failure to maintain building in code-compliant manner. Illumination for exits, exit discharges and public corridors per bc 1006.1; 27-381. Noted: emergency illuminated discharge exitsNothing owed — awaiting certificate of correction
ECB04/08/2026Failure to maintain building in code-compliant manner.noted:flag pole not functioning due to missing pulley and has not worked for awhile,observed upon inspection.rem:repair and/or replace.Nothing owed — awaiting certificate of correction
ECB04/08/2026Failure to maintain building in code compliant manner.noted:fire ratedclassrooms and smoke doors not self-closing due to binding,missing andor faulty hardware on classrooms 4C,2C,4D,5B,3C,3D,3A,3B,including smoNothing owed — awaiting certificate of correction
ECB04/08/2026Failure to maintain building in code-compliant manner.noted:stairs leading to emergency exterior exit 6 has spalling cracked and loose terrazzo tread step observed upon inspection.rem:repair and/or replace.Nothing owed — awaiting certificate of correction
ECB04/08/2026Failure to maintain building in code compliant manner.noted:walkway concrete paved pad stairway at exp#4 has missing concrete,spalling and cracked around perimeter of sewer across causing,ankle twisting and orNothing owed — awaiting certificate of correction
ECB04/08/2026Failure to maintain building in code-compliant manner.noted:step at exp#2 on facade by exit 6 and at exp#1 decorative ceramic tile missing,including missing mortar between brick at intermediate roof at bulkheadNothing owed — awaiting certificate of correction
ECB04/08/2026Reissue#35719800N failure to maintain building in code-compliant manner.illumination for exits,exit discharges and public corridors per bc 1006.1;27-381.noted:emergency illuminated exit discharge boxes not workNothing owed — awaiting certificate of correction
ECB04/08/2026Failure to maintain building in code-compliant manner.noted:cracked wire mesh glass vision panels on classroom 3C and smoke door west entrance/left door observed upon inspection.rem:repair and/or replace.Nothing owed — awaiting certificate of correction
ECB04/08/2026Reissue on ECB 35717492L. Failure to maintain building in code-compliant manner. Use of prohibited door and/or hardware per bc 1008.1.8; 27-371(j). Noted: installation of illegal kick stops on fire rated and smNothing owed — awaiting certificate of correction
ECB04/08/2026Reissue on ECB #35717499Y. Failure to maintain building in code-compliant manner. Noted: spalling plaster on foundation wall at cellar levelstairwell d due to water damage from water seepage through porous wallNothing owed — awaiting certificate of correction
ECB04/08/2026Reissue on ECB #35717493N. Failure to maintain building in code-compliant manner. Noted: missin and/or removed fire rated smoke doors on 3RDFLOOR corridor by 326 classroom and 2ND floor corridor by classroom 20Nothing owed — awaiting certificate of correction
ECB09/05/2025Failure to maintain building in code-compliant manner. Noted missing/removed cross corridor smoke doors at 3RD fl by rm #326, 2ND fl by rm #208 and rm #226. Cafeteria entry doors missing door mullion creating "Nothing owed — awaiting certificate of correction
ECB09/05/2025Failure to maintain building in code-compliant manner. Noted spalling plaster on wall at cellar level stairwell d due to water infiltration from exterior. Remedy: repair and/or replace.Nothing owed — awaiting certificate of correction
ECB09/05/2025Failure to maintain building in code-compliant manner: use of prohibited door and/or hardware per bc 1008.1; 27-371(j). Noted illegal kickdown door stops mounted on fpsc doors in classroom #330, 329, 328, 313,Nothing owed — awaiting certificate of correction
ECB09/05/2025Failure to maintain building in code-compliant manner: illumination for exit, exit discharges and public corridors per bc 1006.1; 27-381. Noted approx. 9 emergency lights not working when tested throughout tranNothing owed — awaiting certificate of correction
ECB09/05/2025Failure to maintain building in code-compliant manner: illumination for exits; exit discharges and public corridors per bc 1006.1; 27-381. Noted approx 95% of emergency lights not working throughout the schoolNothing owed — awaiting certificate of correction
ECB09/05/2025Exit door not self-closing. Exterior doors at exit #2 and 6 were not self-closing properly due to defective closer devices or being rached. Remedy: repair/replace door.Nothing owed — awaiting certificate of correction
ECB09/05/2025Failure to maintain building in code-compliant manner. Facade in disrepair. Crumbling/spalling cement at exits #5, 4 and 2 overhang above door underside. At exp #2 by exit #6 large step crack in masonry wall coNothing owed — awaiting certificate of correction
ECB07/17/2025Failure to maintain building in code-compliant manner. Observed @ EXIT3 main entrance from baychester ave vestibule, 3 out of 4 door not closed properly when tested door to door check defective. Remedy: repairNothing owed — awaiting certificate of correction
ECB06/26/2025Failure to maintain building in code-compliant manner. Noted exterior stone knee wall around school's perimeter has several areas with cracks and missing of loose stone pieces throughout all exposures. Remedy:Nothing owed — awaiting certificate of correction
ECB07/15/2010Exterior foundation wall has become porous & allowing rain into the bldg causing interior damages in the boiler room @ cellar level adjacentto baychester.rem:water-proof exterior foundation wallNothing owed — awaiting certificate of correction
Likely answered · the city's own records show a filing, but DOB's feed still lists these as active
DOB11/14/2025Violation issued-failure to file 2024 external low pressure inspectionThe owner has filed since: boiler inspection reports are on file for later years (latest 2026). This one is not shown as answered2 identical filings