← Back
Five to six families
376 WOODWARD AVENUE
QUEENS · Ridgewood · BIN 4081181
💬 Discuss this project
1914Year Built
3Stories
C2Building Class
R6BZoning
5,994 sfGross Floor Area
6Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Five to six families · Owner of record: KINGDOMWERKS, LLC · 2,893 sf lot · 2.07 FAR built · Flood zone X
Locations of Work
ArchitectureMechanical
Roof7p · 1 filing · 20 docs
Floor 37p · 1 filing · 20 docs
Floor 26p · 1 filing · 20 docs
Floor 17p · 1 filing · 20 docs
Cellar7p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
KINGDOMWERKS, LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/19/2022$2.5M—— → —$417/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JOHN P. FOX, ARCHITECT, PC.401/05/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CORNERSTONE CONSULTING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KLE CONSTRUCTION INCGeneral Contractor207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SD TESTING & INSPECTION S7010401/05/2026
YL DESIGN GROUP LLC7584111/03/2023
Building Lifecycle
All (77)Filed (4)Permit Issued (2)Signed Off (1)Violation (49)Special Inspection (21)
04/29/2026
Signed off — Alteration
HEREBY FILING GENERAL CONSTRUCTION AND MECHANCIAL WORK AS PER PLANS.
Q08008601-I1
01/06/2026
Special inspection requirement — HVAC-R and service water heating equipment
Yuan Liu
01/06/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Yuan Liu
01/06/2026
Special inspection requirement — HVAC-R and service water heating system controls
Yuan Liu
01/06/2026
Special inspection requirement — Final
Yuan Liu
01/06/2026
Special inspection requirement — Mechanical Systems
XIUCHENG LI
01/06/2026
Special inspection requirement — Tenant Protection Plan Compliance
Yuan Liu
01/05/2026
Filed — Alteration
HEREBY FILING GENERAL CONSTRUCTION AND MECHANCIAL WORK AS PER PLANS.
Q08008601-P3
01/02/2026
Special inspection requirement — HVAC-R and service water heating equipment
Yuan Liu
01/02/2026
Special inspection requirement — HVAC-R and service water heating system controls
Yuan Liu
01/02/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Yuan Liu
01/02/2026
Special inspection requirement — HVAC-R and service water heating system controls
Yuan Liu
01/02/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Yuan Liu
01/02/2026
Special inspection requirement — HVAC-R and service water heating equipment
Yuan Liu
01/02/2026
Special inspection requirement — Mechanical Systems
XIUCHENG LI
01/02/2026
Special inspection requirement — Tenant Protection Plan Compliance
01/02/2026
Special inspection requirement — Final
Yuan Liu
11/05/2025
Filed — Alteration
HEREBY FILING GENERAL CONSTRUCTION AND MECHANCIAL WORK AS PER PLANS.
Q08008601-P2
09/08/2025
Violation issued (HPD, closed)
A
09/08/2025
Violation issued (HPD, closed)
B
09/08/2025
Violation issued (HPD, closed)
C
09/08/2025
Violation issued (HPD, closed)
A
07/17/2025
Violation issued (HPD, closed)
A
07/17/2025
Violation issued (HPD, closed)
A
07/17/2025
Violation issued (HPD, closed)
C
07/17/2025
Violation issued (HPD, closed)
A
07/17/2025
Violation issued (HPD, closed)
B
07/17/2025
Violation issued (HPD, closed)
B
06/24/2025
Violation issued (HPD, closed)
B
06/24/2025
Violation issued (HPD, closed)
B
06/24/2025
Violation issued (HPD, closed)
B
06/24/2025
Violation issued (HPD, closed)
C
03/14/2025
Violation issued (HPD, closed)
B
02/04/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Yuan Liu
02/04/2025
Special inspection requirement — HVAC-R and service water heating system controls
Yuan Liu
02/04/2025
Special inspection requirement — HVAC-R and service water heating equipment
Yuan Liu
02/04/2025
Special inspection requirement — Final
Yuan Liu
02/04/2025
Special inspection requirement — Mechanical Systems
XIUCHENG LI
02/04/2025
Special inspection requirement — Tenant Protection Plan Compliance
01/24/2025
Violation issued (HPD, closed)
C
01/24/2025
Violation issued (HPD, closed)
C
01/24/2025
Violation issued (HPD, closed)
C
01/24/2025
Violation issued (HPD, closed)
B
01/24/2025
Violation issued (HPD, closed)
A
01/24/2025
Violation issued (HPD, closed)
A
01/24/2025
Violation issued (HPD, closed)
C
01/24/2025
Violation issued (HPD, closed)
B
01/24/2025
Violation issued (HPD, closed)
C
01/24/2025
Violation issued (HPD, closed)
C
01/24/2025
Violation issued (HPD, closed)
A
01/24/2025
Violation issued (HPD, closed)
C
01/24/2025
Violation issued (HPD, closed)
C
01/24/2025
Violation issued (HPD, closed)
A
01/23/2025
Violation issued (HPD, closed)
C
01/07/2025
Filed — Alteration
HEREBY FILING GENERAL CONSTRUCTION AND MECHANCIAL WORK AS PER PLANS.
Q08008601-P1
12/02/2024
Violation issued (HPD, closed)
I
06/12/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/16/2024
Violation issued (HPD, closed)
A
04/02/2024
Violation issued (ECB, closed)
Construction
03/21/2024
Permit issued — Mechanical Systems
Q08008601-I1-MS
Latest 60 of 77 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offKLE CONSTRUCTION INC03/21/2024
DOB NOWGeneral ConstructionSigned-offKLE CONSTRUCTION INC03/21/2024
BISOTISSUEDLEE, SHIN EUN09/22/2020
BISOTISSUEDLEE, SHIN EUN10/03/2019
1 project · most recent 01/05/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
01/05/2026Signed-offKLE CONSTRUCTION INCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MITSUBISHI - LMN079HVT 7,000 BTU · Vrf Indoor ×12
Mitsubishi H2i Hyper-Heating 36,000 BTU 4-Zone Smart Multi Heat Pump Unit - MODEL # MXZSM36NAMHZ2 36,000 BTU · Condensing Unit ×28
MITSUBISHI - MSZGL09NA 9,000 BTU · Ahu ×36
MITSUBISHI - MSZGL15NA 14,300 BTU · Ahu ×21
MITSUBISHI - MSZGL24NA 24,000 BTU · Ahu ×1
MITSUBISHI - MSZGL06NA 7,000 BTU · Ahu ×18
MITSUBISHI - MSZGL18NA 18,000 BTU · Ahu ×9
2 projects · most recent 03/26/2024
General Wiring
FiledStatusContractorScope
03/26/2024Permit IssuedPROJECT ONE ELECTRIC INCGeneral Wiring
10/02/2019CompleteSEONG JIN ELECTRIC INC.General Wiring
▾Special Inspection Requirements (DOB NOW) — 21
DateRequirementInspectorRole
01/06/2026HVAC-R and service water heating equipmentYuan Liuenergy_progress
01/06/2026HVAC-R and service water piping design and insulationYuan Liuenergy_progress
01/06/2026HVAC-R and service water heating system controlsYuan Liuenergy_progress
01/06/2026FinalYuan Liuprogress
01/06/2026Mechanical SystemsXIUCHENG LIspecial
01/06/2026Tenant Protection Plan ComplianceYuan Liuspecial
01/02/2026HVAC-R and service water heating equipmentYuan Liuenergy_progress
01/02/2026HVAC-R and service water heating system controlsYuan Liuenergy_progress
01/02/2026HVAC-R and service water piping design and insulationYuan Liuenergy_progress
01/02/2026HVAC-R and service water heating system controlsYuan Liuenergy_progress
01/02/2026HVAC-R and service water piping design and insulationYuan Liuenergy_progress
01/02/2026HVAC-R and service water heating equipmentYuan Liuenergy_progress
01/02/2026Mechanical SystemsXIUCHENG LIspecial
01/02/2026Tenant Protection Plan Compliance—special
01/02/2026FinalYuan Liuprogress
02/04/2025HVAC-R and service water piping design and insulationYuan Liuenergy_progress
02/04/2025HVAC-R and service water heating system controlsYuan Liuenergy_progress
02/04/2025HVAC-R and service water heating equipmentYuan Liuenergy_progress
02/04/2025FinalYuan Liuprogress
02/04/2025Mechanical SystemsXIUCHENG LIspecial
02/04/2025Tenant Protection Plan Compliance—special
▾Documents — 70 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/17/2026Q08008601-P1Request digital key ↗
08/17/2026Q08008601-P3Request digital key ↗
08/17/2026Q08008601-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits13
▸BISPLAN / WORK APPROVAL APPLICATION6
11/22/2022421914995Open ↗
04/02/2021421773637Open ↗
07/06/2020421773637Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWLPC Approval/Permit4
08/13/2026Q08008601-P2Open ↗
08/13/2026Q08008601-P3Open ↗
08/13/2026Q08008601-I1Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION3
10/28/2020421773637Open ↗
10/04/2019421914995Open ↗
12/01/2018421633977Open ↗
▸Seals & Professional Certifications28
▸DOB NOWProgress Inspector Seal & Signature12
08/27/2026Q08008601-P2Open ↗
08/27/2026Q08008601-P2Open ↗
08/27/2026Q08008601-P2Open ↗
Showing 3 of 12 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
07/06/2020421773637Open ↗
12/12/2019421633977Open ↗
09/11/2019421914995Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/13/2026Q08008601-P1Open ↗
08/13/2026Q08008601-I1Open ↗
08/13/2026Q08008601-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/27/2026Q08008601-P2Open ↗
08/26/2026Q08008601-I1Open ↗
08/26/2026Q08008601-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
09/11/2019421914995Open ↗
05/24/2018421633977Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
09/11/2019421914995Open ↗
05/24/2018421633977Open ↗
▸Safety & Tenant Protection2
▸BISTenant Protection Plan and Notes2
07/06/2020421773637Open ↗
09/11/2019421914995Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/13/2026Q08008601-I1Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
09/06/2022421914995Open ↗
04/02/2021421773637Open ↗
▸BISTR8: ENERGY CODE PROGRESS INSPS TECHNICAL REPORT1
08/18/2020421773637Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
09/11/2019421914995Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY2
09/06/2022421914995Open ↗
04/02/2021421773637Open ↗
▸BISINSPECTION REPORT - SUPPORTING DOCUMENTATION1
12/12/2019421633977Open ↗
▸Approvals, Objections & Sign-offs5
▸BISLETTERS - SUPPORTING DOCUMENTATION2
07/06/2020421773637Open ↗
11/10/2018421633977Open ↗
▸BISLANDMARKS APPROVAL2
12/12/2019421633977Open ↗
09/11/2019421914995Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
12/12/2019421633977Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
07/06/2020421773637Open ↗
12/12/2019421633977Open ↗
09/11/2019421914995Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms6
▸BISEFILING COVER SHEET3
07/06/2020421773637Open ↗
09/11/2019421914995Open ↗
05/24/2018421633977Open ↗
▸BISBOROUGH INTAKE FORM3
11/22/2022421914995Open ↗
10/28/2020421773637Open ↗
11/14/2019421633977Open ↗