← Back
BuildNYC
Five to six families
379 12TH STREET
BROOKLYN · Park Slope · BIN 3023039
💬 Discuss this project
2024Year Built
3Stories
C2Building Class
R6BZoning
8,591 sfGross Floor Area
6Units
1 Active Violation ▸FDNY Report ↗
Five to six families · Owner of record: 379 12th Street · 4,367 sf lot · 1.97 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofProposed new six family dwelling8p · 4 filings · 20 docs
PenthouseProposed Three (3) Story, Penthouse & Cellar53p · 4 filings · 20 docs
Floor 3Proposed Three (3) Story, Penthouse & Cellar53p · 4 filings · 20 docs
Floor 2Proposed Three (3) Story, Penthouse & Cellar53p · 4 filings · 20 docs
Floor 1Proposed Three (3) Story, Penthouse & Cellar53p · 4 filings · 20 docs
CellarProposed Three (3) Story, Penthouse & Cellar61p · 4 filings · 20 docs
Site & exteriorSidewalk shed and pipe scaffolding installation35p · 5 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
379 12th Street8104/09/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/13/2020$2.9M—Private party → 379 12th Street— not available
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Design Studio Associates808/05/2025
Tom Petersen Architect205/22/2025
Ashraf306/07/2024
Yaker Engineering202/29/2024
Afm Inspections & Engineering809/20/2023
Paul Perdek, Prof. Engineering103/03/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Design Studio Associates1703/21/2026
AE Design Solution203/21/2026
Demoworks Expediting203/21/2026
Platinum Services NY603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Avo ConstructionGeneral Contractor1704/09/2026
Avo ConstructionScaffold1304/09/2026
Platinum Services NYScaffold1203/21/2026
Nycom ElectricalElectrical303/21/2026
Design Studio AssociatesGeneral Contractor303/22/2026
Nycom ElectricalGeneral Contractor303/22/2026
Plumbing NYCFire Protection207/08/2026
Core Scaffold SystemsScaffold204/09/2026
Paul LombardiElectrical203/21/2026
Plumbing NYCPlumbing107/08/2026
Energy Brite Ins & SolarGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Regional Testing3941508/05/2025
Thomas Petersen Architect7854205/22/2025
Building Lifecycle
All (193)Filed (24)Permit Issued (28)Signed Off (10)Violation (13)Inspection (8)Objection (80)Special Inspection (30)
04/21/2026
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/30/2026
Violation issued (ECB, closed)
Construction
01/12/2026
Signed off — New Building
SOE APPLICATION FILED IN CONJUNCTION WITH NB B00498781
B00498781-I1
10/09/2025
Signed off — Alteration
STRUCTURAL WORK FOR PROPOSED THREE (3) STORY, PENTHOUSE AND CELLAR, SIX (6) FAMILY DWELLING
B08029460-I1
10/08/2025
Signed off — Alteration
Installation of PV system on existing roof, no changes to egress or use of occupancy
B01208037-I1
09/29/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/26/2025
Signed off — Alteration
INSTALLATION OF RESIDENTIAL SPRINKLER SYSTEM AS PER PLANS FILED HEREWITH IN CONJUNCTION WITH NB B00498781
B00554923-I1
09/24/2025
Signed off — Alteration
B00554994-I1
09/12/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
09/11/2025
Violation issued (ECB, closed)
Construction
09/10/2025
Permit issued — Sprinklers
B00554923-I1-EW-SP
09/10/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
09/10/2025
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
08/21/2025
Permit issued — General Construction
B08029460-I1-ST
08/12/2025
Special inspection requirement — Lighting in dwelling units
Paul Raymond
08/12/2025
Special inspection requirement — Lighting controls
Paul Raymond
08/12/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Paul Raymond
08/12/2025
Special inspection requirement — Exterior lighting power
Paul Raymond
08/12/2025
Special inspection requirement — Interior lighting power
Paul Raymond
08/12/2025
Special inspection requirement — Masonry
Paul Raymond
08/12/2025
Special inspection requirement — Underpinning
Paul Raymond
08/12/2025
Special inspection requirement — Subgrade Inspections
Paul Raymond
08/12/2025
Special inspection requirement — Air barrier - visual inspection
Paul Raymond
08/12/2025
Special inspection requirement — Fenestration areas
Paul Raymond
08/12/2025
Special inspection requirement — Vestibules
Paul Raymond
08/12/2025
Special inspection requirement — Protection of exposed foundation insulation
Paul Raymond
08/12/2025
Special inspection requirement — Fenestration air leakage
Paul Raymond
08/12/2025
Special inspection requirement — Maintenance information
Paul Raymond
08/12/2025
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
Paul Raymond
08/12/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Paul Raymond
08/12/2025
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
Paul Raymond
08/12/2025
Special inspection requirement — Concrete - Cast-In-Place
Paul Raymond
08/12/2025
Special inspection requirement — Energy Code Compliance Inspections
Paul Raymond
08/12/2025
Special inspection requirement — Fire-Resistance Rated Construction
Paul Raymond
08/12/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Paul Raymond
08/12/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Paul Raymond
08/12/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Daniel Boss
08/12/2025
Special inspection requirement — Insulation placement and R values
Paul Raymond
08/12/2025
Special inspection requirement — Permanent certificate
Paul Raymond
08/07/2025
Signed off — Alteration
B00442686-I1
08/05/2025
Filed — Alteration
INSTALLATION OF RESIDENTIAL SPRINKLER SYSTEM AS PER PLANS FILED HEREWITH IN CONJUNCTION WITH NB B00498781
B00554923-P1
08/04/2025
Special inspection requirement — Sprinkler Systems
Paul Raymond
08/04/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Paul Raymond
07/31/2025
Filed — New Building
SOE APPLICATION FILED IN CONJUNCTION WITH NB B00498781
B00498781-P5
07/29/2025
Special inspection requirement — Exterior lighting power
Paul Raymond
07/29/2025
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
Paul Raymond
07/29/2025
Special inspection requirement — Air barrier - visual inspection
Paul Raymond
06/13/2025
Permit issued — Construction Fence
B00442686-I1-FN
06/13/2025
Permit issued — General Construction
B00498781-I1-GC
05/23/2025
Permit issued — Solar
B01208037-I1-SL
05/22/2025
Filed — Alteration
Installation of PV system on existing roof, no changes to egress or use of occupancy
B01208037-P2
04/30/2025
Signed off — Alteration
INSTALLATION OF 300 PSF SIDEWALK SHED, PIPE SCAFFOLDING, AND ROOF PROTECTION AS PER PLANS. ALL EQUIPMENT SHALL COMPLY WITH CHAPTER #33 OF THE 2022 CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00997707-I1
04/28/2025
Violation issued (ECB, closed)
Construction
04/16/2025
Filed — Alteration
Installation of PV system on existing roof, no changes to egress or use of occupancy
B01208037-I1
02/21/2025
Permit issued — Supported Scaffold
B00997707-I1-SF
02/21/2025
Permit issued — Supported Scaffold
B00997707-I1-SH
02/04/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
02/04/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/07/2025
Violation issued (ECB, closed)
Unknown
11/13/2024
Permit issued — Structural
B08029460-I1-GC
Latest 60 of 193 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offPlumbing NYC09/10/2025
DOB NOWGeneral ConstructionSigned-offAvo Construction08/21/2025
DOB NOWConstruction FenceSigned-offAvo Construction06/13/2025
DOB NOWGeneral ConstructionPermit IssuedAvo Construction06/13/2025
DOB NOWSolarSigned-offEnergy Brite Ins & Solar05/23/2025
DOB NOWSupported ScaffoldSigned-offPlatinum Services NY02/21/2025
DOB NOWSupported ScaffoldSigned-offPlatinum Services NY02/21/2025
DOB NOWStructuralSigned-offAvo Construction11/13/2024
DOB NOWGeneral ConstructionSigned-offAvo Construction07/22/2024
DOB NOWGeneral ConstructionPermit IssuedAvo Construction06/20/2024
DOB NOWConstruction FenceSigned-offAvo Construction06/20/2024
DOB NOWPlumbingSigned-offPlumbing Works NYC03/04/2024
DOB NOWSprinklersSigned-offPlumbing NYC03/04/2024
DOB NOWSidewalk ShedSigned-offPlatinum Services NY02/23/2024
DOB NOWSidewalk ShedSigned-offPlatinum Services NY02/23/2024
DOB NOWGeneral ConstructionSigned-offAvo Construction11/22/2023
DOB NOWGeneral ConstructionPermit IssuedAvo Construction08/04/2023
DOB NOWGeneral ConstructionSigned-offAvo Construction08/03/2023
DOB NOWFoundationSigned-offAvo Construction07/27/2023
DOB NOWConstruction FenceSigned-offAvo Construction06/21/2023
DOB NOWSupport of ExcavationSigned-offAvo Construction06/18/2023
DOB NOWSupport of ExcavationSigned-offAvo Construction05/25/2023
DOB NOWConstruction FenceSigned-offAvo Construction06/23/2022
DOB NOWSidewalk ShedSigned-offCore Scaffold Systems03/03/2022
DOB NOWConstruction FenceSigned-offAvo Construction06/23/2021
DOB NOWConstruction FenceSigned-offAvo Construction06/03/2021
DOB NOWSidewalk ShedSigned-offCore Scaffold Systems03/04/2021
DOB NOWConstruction FenceSigned-offAvo Construction02/25/2021
BIS—ISSUEDPaul Toth Excavation06/22/2022
BIS—ISSUEDPaul Toth Excavation06/21/2021
BIS—ISSUEDPaul Toth Excavation03/02/2021
6 projects · most recent 10/16/2025
General Wiring
FiledStatusContractorScope
10/16/2025CompleteNycom Electrical—
05/21/2025CompleteRidge Electric—
03/07/2025CompleteRidge ElectricGeneral Wiring
03/27/2024CompleteIlluminous Electric—
05/17/2022CompleteAround ElectricGeneral Wiring
03/10/2021CompleteV. Vass Electric—
1 project · most recent 07/31/2025
FiledStatusContractorScope
07/31/2025Permit IssuedAvo Construction4 scope_items
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
09/29/2025Pass-Final CND-Occupancy InspectionPassView ↗
09/12/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/10/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
09/10/2025Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
02/04/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
02/04/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/10/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/10/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 117
DateRequirementInspectorRole
08/12/2025MasonryPaul Raymondspecial
08/12/2025Fenestration air leakagePaul Raymondenergy_progress
08/12/2025Maintenance informationPaul Raymondenergy_progress
08/12/2025Interior lighting powerPaul Raymondenergy_progress
08/12/2025Protection of exposed foundation insulationPaul Raymondenergy_progress
08/12/2025Lighting controlsPaul Raymondenergy_progress
08/12/2025Permanent certificatePaul Raymondenergy_progress
08/12/2025VestibulesPaul Raymondenergy_progress
08/12/2025Insulation placement and R valuesPaul Raymondenergy_progress
08/12/2025Lighting in dwelling unitsPaul Raymondenergy_progress
08/12/2025Exterior lighting powerPaul Raymondenergy_progress
08/12/2025Fenestration areasPaul Raymondenergy_progress
08/12/2025Fenestration and door U-factor and product ratingsPaul Raymondenergy_progress
08/12/2025HVAC-R and service water piping design and insulationPaul Raymondenergy_progress
08/12/2025Air barrier - visual inspectionPaul Raymondenergy_progress
08/12/2025Fire-Resistance Rated ConstructionPaul Raymondprogress
08/12/2025Energy Code Compliance InspectionsPaul Raymondprogress
08/12/2025Fire-Resistant Penetrations and JointsPaul Raymondspecial
08/12/2025Subgrade InspectionsPaul Raymondspecial
08/12/2025Concrete - Cast-In-PlacePaul Raymondspecial
08/12/2025Exterior Insulation and Finish Systems (EIFS)Paul Raymondspecial
08/12/2025UnderpinningPaul Raymondspecial
08/12/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationPaul Raymondspecial
08/12/2025Excavations - Sheeting, Shoring, and BracingPaul Raymondspecial
08/12/2025Subsurface Investigations (Borings/Test Pits)Daniel Bossspecial
Latest 25 of 117.
▾Documents — 254 on file (BIS + DOB NOW)
▸Plans & Drawings24
▸DOB NOWPlans/Sketch23
09/01/2026B00479886-I1Request digital key ↗
09/01/2026B00569380-P1Request digital key ↗
08/30/2026B00554923-I1Request digital key ↗
Showing 3 of 23 on file for this type
▸DOB NOWPlans/Sketch - Construction Fence1
09/02/2026B00442686-I1Request digital key ↗
▸Applications & Permits7
▸BISWORK PERMIT APPLICATION3
07/09/2022322089173Open ↗
06/22/2021322089173Open ↗
03/10/2021322089173Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION3
04/29/2025322121191Open ↗
02/09/2024340817815Open ↗
12/01/2020322089173Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
02/02/2024340817815Open ↗
▸Zoning, Tax Lot & Property Records8
▸DOB NOWZD1: DOB Zoning Diagram3
08/13/2026B00498781-P5Open ↗
08/13/2026B00498781-I1Open ↗
08/13/2026B00498781-P4Open ↗
▸DOB NOWZoning Exhibit form (1-5)3
08/13/2026B00498781-P5Open ↗
08/13/2026B00498781-P4Open ↗
08/13/2026B00498781-I1Open ↗
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
05/06/2025322121191Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00498781-I1Open ↗
▸Seals & Professional Certifications138
▸DOB NOWSpecial Inspector Seal & Signature58
09/01/2026B00498781-P4Open ↗
09/01/2026B00498781-P4Open ↗
09/01/2026B00498781-P4Open ↗
Showing 3 of 58 on file for this type
▸DOB NOWProgress Inspector Seal & Signature54
09/01/2026B00498781-P4Open ↗
09/01/2026B00498781-P4Open ↗
09/01/2026B00498781-P4Open ↗
Showing 3 of 54 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature24
09/02/2026B00442686-I1Open ↗
09/01/2026B00479886-I1Open ↗
09/01/2026B00569380-I1Open ↗
Showing 3 of 24 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
02/02/2024340817815Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
02/02/2024340817815Open ↗
▸Trade Schedules & Equipment4
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)3
08/13/2026B00498781-I1Open ↗
08/13/2026B00498781-P4Open ↗
08/13/2026B00498781-P5Open ↗
▸DOB NOWStandpipe Alarms Drawings1
08/15/2026B00498781-I1—
▸Safety & Tenant Protection12
▸DOB NOWStreet Tree Checklist3
08/15/2026B00498781-P4Open ↗
08/15/2026B00498781-I1Open ↗
08/13/2026B00498781-P5Open ↗
▸BISSTREET TREES: RECEIPT OF STREET TREES SITE PLAN1
02/08/2024340817815Open ↗
▸BISBPP: STREET TREES SITE PLAN1
02/08/2024340817815Open ↗
▸BISSTREET TREE CHECKLIST1
02/08/2024340817815Open ↗
▸BISSTREET TREE SIGNOFF1
10/16/2025340817815Open ↗
▸BISSTREET TREES SITE PLAN1
10/16/2025340817815Open ↗
▸BISANTI-HARASSMENT CHECKLIST1
03/10/2021322089173Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWStreet Trees Site Plan1
08/13/2026B00498781-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026B00498781-I1Open ↗
▸Environmental & Asbestos4
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
03/10/2021322089173Open ↗
03/10/2021322089173Open ↗
▸BISRODENT CONTROL2
06/22/2021322089173Open ↗
03/10/2021322089173Open ↗
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026B00498781-I1Open ↗
08/13/2026B00554994-I1Open ↗
▸Inspections & Test Reports10
▸DOB NOWSOIL REPORT7
08/13/2026B00498781-P2Open ↗
08/13/2026B00498781-P4Open ↗
08/13/2026B00498781-S1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram2
08/13/2026B00498781-I1Open ↗
08/13/2026B00498781-S1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026B00498781-S1Open ↗
▸Approvals, Objections & Sign-offs10
▸BISLETTERS - SUPPORTING DOCUMENTATION9
05/06/2025322121191Open ↗
06/22/2021322089173Open ↗
06/22/2021322089173Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026B01208037-I1Open ↗
▸Cost, Insurance & Ownership7
▸BISPROJECT-SPECIFIC GL INSURANCE3
07/09/2022322089173Open ↗
06/22/2021322089173Open ↗
03/10/2021322089173Open ↗
▸BISBPP: ENGINEERS AFFIDAVIT1
10/16/2025340817815Open ↗
▸BISAcord 25 (Acord Certificate of Liability Insurance)1
03/10/2021322089173Open ↗
▸DOB NOWCertificate of Insurance1
08/13/2026B00498781-I1Open ↗
▸DOB NOWCertification by Insurance Broker or Agency1
08/13/2026B00498781-I1Open ↗
▸Filing & Intake Forms7
▸BISADDITIONAL INFORMATION3
02/12/2024340817815Open ↗
07/09/2022322089173Open ↗
06/22/2021322089173Open ↗
▸BISEFILING COVER SHEET2
04/29/2025322121191Open ↗
12/01/2020322089173Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
02/02/2024340817815Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
02/02/2024340817815Open ↗
▸Other Documents21
▸DOB NOWSite Survey: Initial3
08/13/2026B00498781-I1Open ↗
08/13/2026B00498781-P5Open ↗
08/13/2026B00498781-P4Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/13/2026B00498781-P4Open ↗
08/13/2026B00498781-P5Open ↗
Showing 2 of 3 on file for this type
▸DOB NOWSURVEY: INITIAL3
08/13/2026B00498781-P4Open ↗
08/13/2026B00498781-P5Open ↗
Showing 2 of 3 on file for this type
▸BISBPP - SUPPORTING DOCUMENTATION2
02/08/2024340817815Open ↗
02/02/2024340817815Open ↗
▸BISRECORDS MGMT FEE PAYMENT RECEIPT2
05/06/2025322121191Open ↗
02/02/2024340817815Open ↗
▸BISBPP: AS-BUILT SIDEWALK SURVEY1
10/16/2025340817815Open ↗
▸BISBPP: FINAL AS-BUILT PHOTOGRAPHS1
10/16/2025340817815Open ↗
▸BISPLOT DIAGRAM1
05/06/2025322121191Open ↗
▸BISBPP: TOPOGRAPHIC SURVEY1
02/08/2024340817815Open ↗
▸BISBPP: PHOTOS-SIGNED/SEALED BY APPLICANT1
02/08/2024340817815Open ↗
▸DOB NOWFinal Survey1
08/13/2026B00498781-I1Open ↗
▸DOB NOWAdditional Insured Authorizations1
08/13/2026B00498781-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026B00498781-S1Open ↗