One story - permanent living quarter · 3,737 sf lot · 0.29 FAR built · Flood zone X
Locations of Work
General
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof1 filing · 20 docs
Attic1 filing · 20 docs
Floor 21 filing · 20 docs
Floor 11 filing · 20 docs
Cellar1 filing · 20 docs
Filed — no permit issued1p · 1 filing · 2 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Jian Engineering302/18/2025
Jimenez Building Consulting111/22/2024
Yang Engineering410/17/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SD Design Studio1603/21/2026
Building Lifecycle
02/21/2025
Objection resolved — Resolved
02/21/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
02/19/2025
Objection raised — Admin
02/18/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
The foundation system is composed of concrete foundation walls and wall footings.
S00826970-S5
02/18/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
The foundation system is composed of concrete foundation walls and wall footings.
S00826970-S7
42 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Nothing on file for this building.
1 project · most recent 02/18/2025
Associated Ducts and Piping
FiledStatusContractorScope
02/18/2025——Associated Ducts and Piping
1 project · most recent 02/18/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
02/18/2025——Gas, Storm, Water/Sanitary
1 project · most recent 02/18/2025
Concrete Wood
FiledStatusContractorScope
02/18/2025——Concrete, Wood
1 project · most recent 10/17/2024
Fence
FiledStatusContractorScope
10/17/2024——Fence
▾Special Inspection Requirements (DOB NOW) — 40
DateRequirementInspectorRole
02/21/2025Subsurface Investigations (Borings/Test Pits)—special
02/06/2025Subsurface Investigations (Borings/Test Pits)—special
01/17/2025Structural Stability – Alterations of existing buildings—special
01/17/2025Wood – High-Load Diaphragms—special
01/17/2025Wood – Metal-Plate-Connected Trusses—special
01/17/2025Wood – Prefabricated I-Joists—special
01/17/2025Fire-Resistance Rated Construction—progress
01/17/2025Structural Wood Frame—progress
01/17/2025Final—progress
01/17/2025Concrete - Cast-In-Place—special
01/17/2025Footing and Foundation—progress
01/17/2025Subgrade Inspections—special
01/17/2025Final—progress
11/21/2024Permanent certificate—energy_progress
11/21/2024Duct leakage testing, insulation and design—energy_progress
11/21/2024Fenestration air leakage—energy_progress
11/21/2024Air barrier — testing —energy_progress
11/21/2024HVAC-R and service water heating equipment—energy_progress
11/21/2024Fenestration and door U-factor and product ratings—energy_progress
11/21/2024Fenestration areas—energy_progress
11/21/2024Concrete - Cast-In-Place—special
11/21/2024HVAC-R and service water heating system controls—energy_progress
11/21/2024HVAC-R and service water piping design and insulation—energy_progress
11/21/2024Metering—energy_progress
11/21/2024Interior lighting power—energy_progress
Latest 25 of 40.