← Back
Large suburban residence
380 OCEAN TERRACE
💬 Discuss this project
2022Year Built
2Stories
A3Building Class
R1-1Zoning
5,383 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Large suburban residence · Owner of record: ST MARYS APT LLC · 53,998 sf lot · 0.1 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanical
Roof1p · 1 filing · 20 docs
Floor 26p · 1 filing · 20 docs
Floor 16p · 1 filing · 20 docs
Basement8p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ROGERS CALVANICO GROUP PLLC1210/08/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ROGERS CALVANICO GROUP1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
J. MANGONE CONSTRUCTIONGeneral Contractor1807/08/2026
J & A PLUMBING CORPPlumbing407/08/2026
ANCO ELECTL CONTCTNG INCElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ROGERS CALVANICO GROUP PL1324502/07/2024
A TECH ENGINEERING NYC, P6738412/05/2023
Building Lifecycle
All (73)Filed (12)Permit Issued (14)Signed Off (5)Inspection (12)Special Inspection (30)
05/19/2025
Signed off — Alteration
PROPOSED INSTALLATION OF IN-GROUND SWINNING POOL AND ONE STORY CABANA. ALL ACCESSORY TO EXISTING ONE FAMILY DETACHED RESIDNECE. EXISTING RESIDENCE FILED UNDER NB APPLICATION S00602397.
S00727128-I1
05/19/2025
Signed off — Alteration
CONSTRUCTION FENCE FOR LOT: 164
S00596643-I1
05/14/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
04/24/2025
Signed off — New Building
20' TOTAL CURB CUT
S00602397-S2
04/18/2025
Signed off — Alteration
PROPOSED INSTALLATION OF IN-GROUND SWINNING POOL AND ONE STORY CABANA. ALL ACCESSORY TO EXISTING ONE FAMILY DETACHED RESIDNECE. EXISTING RESIDENCE FILED UNDER NB APPLICATION S00602397.
S00727128-S1
04/16/2025
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
04/14/2025
Signed off — New Building
20' TOTAL CURB CUT
S00602397-S1
11/27/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/20/2024
Permit issued — Mechanical Systems
S00602397-I1-MS
10/30/2024
Permit issued — Structural
S00602397-I1-ST
10/11/2024
Permit issued — Curb Cut
S00602397-S2-CC
10/08/2024
Filed — New Building
20' TOTAL CURB CUT
S00602397-S2
02/14/2024
Special inspection requirement — Final
Richard Dailey
02/14/2024
Special inspection requirement — Metering
Richard Dailey
02/14/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Richard Dailey
02/14/2024
Special inspection requirement — Fire-Resistance Rated Construction
Richard Dailey
02/14/2024
Special inspection requirement — Electric vehicle service equipment requirements
Richard Dailey
02/14/2024
Special inspection requirement — Permanent certificate
Richard Dailey
02/14/2024
Special inspection requirement — Structural Steel - Details
Richard Dailey
02/14/2024
Special inspection requirement — Masonry
Richard Dailey
02/14/2024
Special inspection requirement — Subgrade Inspections
Richard Dailey
02/14/2024
Special inspection requirement — Footing and Foundation
Richard Dailey
02/14/2024
Special inspection requirement — Ventilation and air distribution system
Richard Dailey
02/14/2024
Special inspection requirement — Protection of exposed foundation insulation
Richard Dailey
02/14/2024
Special inspection requirement — Interior lighting power
Richard Dailey
02/14/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Richard Dailey
02/14/2024
Special inspection requirement — Mechanical Systems
Richard Dailey
02/14/2024
Special inspection requirement — Concrete - Cast-In-Place
Richard Dailey
02/14/2024
Special inspection requirement — Structural Steel - Welding
Richard Dailey
02/14/2024
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
Richard Dailey
02/14/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
anthony santoro
02/14/2024
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Richard Dailey
02/14/2024
Special inspection requirement — Energy Code Compliance Inspections
Richard Dailey
02/14/2024
Special inspection requirement — Structural Wood Frame
Richard Dailey
02/14/2024
Special inspection requirement — Fenestration areas
Richard Dailey
02/14/2024
Special inspection requirement — Fireplaces
Richard Dailey
02/14/2024
Special inspection requirement — Duct leakage testing, insulation and design
Richard Dailey
02/14/2024
Special inspection requirement — Air barrier - visual inspection
Richard Dailey
02/14/2024
Special inspection requirement — Insulation placement and R values
Richard Dailey
02/14/2024
Special inspection requirement — Fenestration air leakage
Richard Dailey
02/14/2024
Special inspection requirement — Air barrier — testing
Richard Dailey
02/14/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Richard Dailey
02/07/2024
Filed — Alteration
PROPOSED INSTALLATION OF IN-GROUND SWINNING POOL AND ONE STORY CABANA. ALL ACCESSORY TO EXISTING ONE FAMILY DETACHED RESIDNECE. EXISTING RESIDENCE FILED UNDER NB APPLICATION S00602397.
S00727128-P1
02/07/2024
Filed — New Building
20' TOTAL CURB CUT
S00602397-P5
12/05/2023
Filed — New Building
20' TOTAL CURB CUT
S00602397-P4
11/06/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/11/2023
Permit issued — Mechanical Systems
S00727128-I1-GC-CX
05/05/2023
Permit issued — Structural
S00602397-I1-GC-CX
03/14/2023
Permit issued — Plumbing
S00602397-S1-PL
03/14/2023
Permit issued — Plumbing
S00727128-S1-PL
02/10/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/12/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/06/2022
Filed — New Building
20' TOTAL CURB CUT
S00602397-P3
12/05/2022
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
11/16/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/16/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/15/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/15/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/10/2022
Permit issued — Plumbing
S00727128-S1-PL
10/28/2022
Filed — New Building
20' TOTAL CURB CUT
S00602397-P2
Latest 60 of 73 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offJ. MANGONE CONSTRUCTION11/20/2024
DOB NOWStructuralSigned-offJ. MANGONE CONSTRUCTION10/30/2024
DOB NOWCurb CutSigned-offJ. MANGONE CONSTRUCTION10/11/2024
DOB NOWMechanical SystemsSigned-offJ. MANGONE CONSTRUCTION05/11/2023
DOB NOWStructuralPermit IssuedJ. MANGONE CONSTRUCTION05/05/2023
DOB NOWPlumbingSigned-offJ & A PLUMBING CORP03/14/2023
DOB NOWPlumbingSigned-offJ & A PLUMBING CORP03/14/2023
DOB NOWPlumbingSigned-offJ & A PLUMBING CORP11/10/2022
DOB NOWEarth WorkSigned-offJ. MANGONE CONSTRUCTION07/22/2022
DOB NOWConstruction FenceSigned-offJ. MANGONE CONSTRUCTION05/26/2022
DOB NOWStructuralPermit IssuedJ. MANGONE CONSTRUCTION05/26/2022
DOB NOWPlumbingSigned-offJ & A PLUMBING CORP05/16/2022
DOB NOWMechanical SystemsPermit IssuedJ. MANGONE CONSTRUCTION04/15/2022
DOB NOWConstruction FenceSigned-offJ. MANGONE CONSTRUCTION10/18/2021
3 projects · most recent 07/16/2024
General Wiring
FiledStatusContractorScope
07/16/2024CompleteSTATEN ISLAND ELEC CONT.General Wiring
01/02/2024CancelledSTATEN ISLAND ELEC CONT.General Wiring
10/26/2021CompleteANCO ELECTL CONTCTNG INC1 meters, 1 new_meters
1 project · most recent 10/08/2024
Concrete Masonry Wood
FiledStatusContractorScope
10/08/2024Signed-offJ. MANGONE CONSTRUCTIONConcrete, Masonry, Wood
1 project · most recent 10/08/2024
Earthwork
FiledStatusContractorScope
10/08/2024Signed-offJ. MANGONE CONSTRUCTIONEarthwork
▾Field Inspections (DOB CAP) — 12
DateTypeResultReport
05/14/2025Pass-Final General Construction Non-Directive 14PassView ↗
04/16/2025Pass-Final Curb Cut Non-Directive 14PassView ↗
11/27/2024Pass-Final CND-Occupancy InspectionPassView ↗
11/06/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/10/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/12/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/05/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
11/16/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/16/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
11/15/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/15/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/25/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 143
DateRequirementInspectorRole
02/14/2024Protection of exposed foundation insulationRichard Daileyenergy_progress
02/14/2024Mechanical SystemsRichard Daileyspecial
02/14/2024Concrete - Cast-In-PlaceRichard Daileyspecial
02/14/2024Structural Steel - DetailsRichard Daileyspecial
02/14/2024Structural Steel - WeldingRichard Daileyspecial
02/14/2024Exterior Insulation and Finish Systems (EIFS)Richard Daileyspecial
02/14/2024MasonryRichard Daileyspecial
02/14/2024Fire-Resistant Penetrations and JointsRichard Daileyspecial
02/14/2024Subsurface Investigations (Borings/Test Pits)anthony santorospecial
02/14/2024Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationRichard Daileyspecial
02/14/2024Subgrade InspectionsRichard Daileyspecial
02/14/2024Energy Code Compliance InspectionsRichard Daileyprogress
02/14/2024Structural Wood FrameRichard Daileyprogress
02/14/2024Footing and FoundationRichard Daileyprogress
02/14/2024Fire-Resistance Rated ConstructionRichard Daileyprogress
02/14/2024FinalRichard Daileyprogress
02/14/2024Fenestration areasRichard Daileyenergy_progress
02/14/2024FireplacesRichard Daileyenergy_progress
02/14/2024Ventilation and air distribution systemRichard Daileyenergy_progress
02/14/2024Duct leakage testing, insulation and designRichard Daileyenergy_progress
02/14/2024Air barrier - visual inspectionRichard Daileyenergy_progress
02/14/2024Electric vehicle service equipment requirementsRichard Daileyenergy_progress
02/14/2024HVAC-R and service water heating equipmentRichard Daileyenergy_progress
02/14/2024HVAC-R and service water heating system controlsRichard Daileyenergy_progress
02/14/2024Maintenance informationRichard Daileyenergy_progress
Latest 25 of 143.
▾Documents — 138 on file (BIS + DOB NOW)
▸Plans & Drawings12
▸DOB NOWPlans/Sketch12
08/25/2026S00596643-I1Request digital key ↗
08/24/2026S00727128-I1Request digital key ↗
08/24/2026S00727128-P1Request digital key ↗
Showing 3 of 12 on file for this type
▸Applications & Permits3
▸BISBPP-5 - Authorization to the Department of Transportation2
12/30/2020540181863Open ↗
09/03/2020540181863Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
09/03/2020540181863Open ↗
▸Zoning, Tax Lot & Property Records23
▸DOB NOWRestrictive Declaration/Easement 18
08/23/2026S00602397-I1Open ↗
08/23/2026S00602397-P5Open ↗
08/23/2026S00602397-P4Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWRestrictive Declaration/Easement 28
08/23/2026S00602397-I1Open ↗
08/23/2026S00602397-P5Open ↗
08/23/2026S00602397-P4Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram3
08/23/2026S00602397-P5Open ↗
08/23/2026S00602397-I1Open ↗
08/23/2026S00602397-P1Open ↗
▸DOB NOWZoning Exhibit form (1-5)3
08/23/2026S00602397-I1Open ↗
08/23/2026S00602397-P5Open ↗
08/23/2026S00602397-P1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/23/2026S00602397-I1Open ↗
▸Seals & Professional Certifications50
▸DOB NOWSpecial Inspector Seal & Signature21
08/29/2026S00602397-I1Open ↗
08/29/2026S00602397-I1Open ↗
08/29/2026S00602397-I1Open ↗
Showing 3 of 21 on file for this type
▸DOB NOWProgress Inspector Seal & Signature15
08/29/2026S00602397-I1Open ↗
08/29/2026S00602397-I1Open ↗
08/29/2026S00602397-I1Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature12
08/24/2026S00727128-P1Open ↗
08/24/2026S00727128-S1Open ↗
08/24/2026S00727128-I1Open ↗
Showing 3 of 12 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
09/03/2020540181863Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
09/03/2020540181863Open ↗
▸Trade Schedules & Equipment4
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)3
08/23/2026S00602397-P5Open ↗
08/23/2026S00602397-P1Open ↗
08/23/2026S00602397-I1Open ↗
▸DOB NOWStandpipe Alarms Drawings1
08/23/2026S00602397-I1—
▸Safety & Tenant Protection6
▸DOB NOWStreet Tree Checklist3
08/23/2026S00602397-P5Open ↗
08/23/2026S00602397-I1Open ↗
08/23/2026S00602397-P1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/23/2026S00602397-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/23/2026S00602397-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/23/2026S00602397-I1Open ↗
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
08/23/2026S00602397-I1Open ↗
08/13/2026S00727128-I1Open ↗
▸Inspections & Test Reports11
▸DOB NOWSOIL REPORT5
08/23/2026S00602397-I1Open ↗
08/23/2026S00602397-P5Open ↗
08/23/2026S00602397-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram2
08/23/2026S00602397-I1Open ↗
08/13/2026S00727128-I1Open ↗
▸DOB NOWTR4 Plot Diagram2
08/23/2026S00602397-I1Open ↗
08/13/2026S00727128-I1Open ↗
▸BISBPP-9 - Request for Builders Pavement Field Inspection1
09/03/2020540181863Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
09/03/2020540181863Open ↗
▸Approvals, Objections & Sign-offs4
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff3
10/01/2024540181863Open ↗
12/30/2020540181863Open ↗
09/03/2020540181863Open ↗
▸BISNYS DEC FRESHWATER WETLANDS APPROVAL1
09/03/2020540181863Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
09/03/2020540181863Open ↗
▸Other Documents22
▸DOB NOWProperty Ownership Certification7
08/23/2026S00602397-P2Open ↗
08/23/2026S00602397-I1Open ↗
08/23/2026S00602397-P5Open ↗
Showing 3 of 7 on file for this type
▸BISBPP - SUPPORTING DOCUMENTATION3
12/30/2020540181863Open ↗
09/03/2020540181863Open ↗
09/03/2020540181863Open ↗
▸DOB NOWSite Survey: Initial3
08/23/2026S00602397-I1Open ↗
08/23/2026S00602397-P5Open ↗
08/23/2026S00602397-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/23/2026S00602397-P5Open ↗
08/23/2026S00602397-P1Open ↗
08/23/2026S00602397-I1Open ↗
▸BISBPP - DOT Builders Pavement Unit Waiver Request Form2
12/30/2020540181863Open ↗
09/03/2020540181863Open ↗
▸DOB NOWAdjoining Owners Notification2
08/23/2026S00602397-I1Open ↗
08/13/2026S00727128-I1Open ↗
▸BISNYS DEC FRESHWATER WETLANDS MAP1
09/03/2020540181863Open ↗
▸DOB NOWFinal Survey1
08/23/2026S00602397-I1Open ↗