← Back
Two stories - detached, small or mid-size
381 EAST 165 STREET
BRONX · Concourse-Concourse Village · BIN 2002048
💬 Discuss this project
1906Year Built
2Stories
A1Building Class
R7-1Zoning
2,908 sfGross Floor Area
1Units
2 Open Violations ▸
Two stories - detached, small or mid-size · 2,613 sf lot · 1.11 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction2p · 1 filing · 20 docs
Floor 2Under Construction8p · 1 filing · 20 docs
Floor 1Under Construction9p · 1 filing · 20 docs
CellarUnder Construction7p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/24/2024$710K—Private party → Private party$244/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
OMF ARCHITECT PC407/13/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
TREASURE BOX SERVICES603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BUILD UP RESTORATION LLCGeneral Contractor707/08/2026
COPPER PLUMBING INCPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
OMF ARCHITECTS PC5900307/13/2026
Building Lifecycle
All (29)Filed (4)Permit Issued (7)Violation (2)Inspection (4)Objection (2)Special Inspection (10)
07/24/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
OSCAR FUERTES
07/13/2026
Filed — Alteration
Proposed installation of HVAC to provide heat and cool for this one family residential building as per plans.
X01146806-P1
04/21/2026
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
03/04/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
01/09/2026
Permit issued — Mechanical Systems
X01146806-S2-MS
01/07/2026
Permit issued — General Construction
X01146806-I1-GC
11/21/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/21/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/27/2025
Permit issued — General Construction
X01146806-I1-GC
10/27/2025
Permit issued — Mechanical Systems
X01146806-S2-MS
07/10/2025
Permit issued — Mechanical Systems
X01146806-S2-MS
07/01/2025
Filed — Alteration
Proposed installation of HVAC to provide heat and cool for this one family residential building as per plans.
X01146806-S2
07/01/2025
Special inspection requirement — HVAC-R and service water heating system controls
OSCAR FUERTES
07/01/2025
Special inspection requirement — Duct leakage testing, insulation and design
OSCAR FUERTES
06/30/2025
Special inspection requirement — Ventilation and air distribution system
OSCAR FUERTES
06/30/2025
Special inspection requirement — Shutoff dampers
OSCAR FUERTES
06/26/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
OSCAR FUERTES
06/26/2025
Special inspection requirement — HVAC-R and service water heating equipment
OSCAR FUERTES
06/26/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
OSCAR FUERTES
05/21/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
05/21/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/04/2025
Permit issued — Plumbing
X01146806-S1-PL
01/30/2025
Permit issued — General Construction
X01146806-I1-GC
01/27/2025
Filed — Alteration
Proposed installation of HVAC to provide heat and cool for this one family residential building as per plans.
X01146806-S1
01/27/2025
Objection resolved — Addressed
01/24/2025
Objection raised — Scope
01/22/2025
Filed — Alteration
Proposed installation of HVAC to provide heat and cool for this one family residential building as per plans.
X01146806-I1
01/13/2025
Special inspection requirement — Final
Nicolas Fuertes La Rotta
01/13/2025
Special inspection requirement — Mechanical Systems
OSCAR FUERTES
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedBUILD UP RESTORATION LLC01/09/2026
DOB NOWGeneral ConstructionPermit IssuedBUILD UP RESTORATION LLC01/07/2026
DOB NOWGeneral ConstructionPermit IssuedBUILD UP RESTORATION LLC10/27/2025
DOB NOWMechanical SystemsPermit IssuedBUILD UP RESTORATION LLC10/27/2025
DOB NOWMechanical SystemsPermit IssuedBUILD UP RESTORATION LLC07/10/2025
DOB NOWPlumbingPermit IssuedCOPPER MECHANICAL INC03/04/2025
DOB NOWGeneral ConstructionPermit IssuedBUILD UP RESTORATION LLC01/30/2025
1 project · most recent 07/13/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/13/2026Permit IssuedBUILD UP RESTORATION LLCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MXZ-SM48NAM 48,000 BTU · Condensing Unit ×3
1 project · most recent 07/13/2026
Gas Water/Sanitary
FiledStatusContractorScope
07/13/2026Permit IssuedCOPPER PLUMBING INCGas, Water/Sanitary
1 project · most recent 04/07/2025
General Wiring
FiledStatusContractorScope
04/07/2025Permit IssuedAMKRO ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
04/21/2026Pass-Final General Construction Non-Directive 14PassView ↗
03/04/2026Fail-Final General Construction Non-Directive 14FailView ↗
05/21/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/21/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
07/24/2026Fire-Resistant Penetrations and JointsOSCAR FUERTESspecial
07/01/2025HVAC-R and service water heating system controlsOSCAR FUERTESenergy_progress
07/01/2025Duct leakage testing, insulation and designOSCAR FUERTESenergy_progress
06/30/2025Ventilation and air distribution systemOSCAR FUERTESenergy_progress
06/30/2025Shutoff dampersOSCAR FUERTESenergy_progress
06/26/2025Fire-Resistant Penetrations and JointsOSCAR FUERTESspecial
06/26/2025HVAC-R and service water heating equipmentOSCAR FUERTESenergy_progress
06/26/2025HVAC-R and service water piping design and insulationOSCAR FUERTESenergy_progress
01/13/2025FinalNicolas Fuertes La Rottaprogress
01/13/2025Mechanical SystemsOSCAR FUERTESspecial
▾Documents — 30 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/20/2026X01146806-I1Request digital key ↗
08/20/2026X01146806-P1Request digital key ↗
08/20/2026X01146806-S2Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits4
▸DOB NOWLPC Approval/Permit4
08/20/2026X01146806-P1Open ↗
08/13/2026X01146806-I1Open ↗
08/13/2026X01146806-S1Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications14
▸DOB NOWProgress Inspector Seal & Signature7
09/23/2026X01146806-S2Open ↗
09/23/2026X01146806-S2Open ↗
09/23/2026X01146806-S2Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/20/2026X01146806-I1Open ↗
08/20/2026X01146806-P1Open ↗
08/20/2026X01146806-S2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/23/2026X01146806-S2Open ↗
09/23/2026X01146806-S2Open ↗
08/26/2026X01146806-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/20/2026X01146806-I1Open ↗
08/20/2026X01146806-P1Open ↗
08/20/2026X01146806-S2Open ↗
Showing 3 of 4 on file for this type
▸Approvals, Objections & Sign-offs4
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter4
08/20/2026X01146806-P1Open ↗
08/13/2026X01146806-S2Open ↗
08/13/2026X01146806-S1Open ↗
Showing 3 of 4 on file for this type