← Back
Elevator cooperative
382 2 AVENUE
MANHATTAN · BIN 1020569
💬 Discuss this project
1965Year Built
16Stories
D4Building Class
R8BZoning
189,616 sfGross Floor Area
266Units
LL97 CoveredRent Stabilized12 Open Violations ▸FISP: SWARMP
Elevator cooperative · Owner of record: 301 EAST 22ND STREET TENANTS CORP · 19,684 sf lot · 9.63 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction9p · 2 filings · 8 docs
Floor 16Under Construction7p · 1 filing · 5 docs
Floor 15Under Construction7p · 1 filing · 5 docs
Floor 14Under Construction7p · 1 filing · 5 docs
Floor 13Under Construction7p · 1 filing · 5 docs
Floor 12Under Construction7p · 1 filing · 5 docs
Floor 11Under Construction7p · 1 filing · 5 docs
Floor 10Under Construction13p · 2 filings · 14 docs
Floor 9Under Construction11p · 2 filings · 20 docs
Floor 8Under Construction7p · 1 filing · 5 docs
Floor 7Under Construction7p · 1 filing · 5 docs
Floor 6Under Construction7p · 1 filing · 5 docs
Floor 5Under Construction7p · 2 filings · 9 docs
Floor 4Under Construction7p · 1 filing · 5 docs
Floor 3Under Construction7p · 1 filing · 5 docs
Floor 2Under Construction19p · 3 filings · 18 docs
Floor 1Under Construction14p · 5 filings · 20 docs
1 job · most recent 04/05/2022
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
04/05/2022——Air Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Mitsubishi Electric PLFY-P18NFMU 18,000 BTU · Vrf Indoor ×5
PUHY-P72TNU-A 72,000 BTU · Vrf Outdoor ×1
Heating
Mitsubishi Electric PLFY-P18NFMU 20,000 BTU · Vrf Indoor ×5
PUHY-P72TNU-A 80,000 BTU · Vrf Outdoor ×1
Ventilation
Greenheck CSP-A390VG 300 CFM · Exhaust Fan ×1
1 job · most recent 04/05/2022
FiledStatusContractorScope
04/05/2022——33 heads
3 jobs · most recent 03/12/2026
Water/Sanitary Gas
FiledStatusContractorScope
03/12/2026Permit IssuedJOHN FITZGERALD PLBG &HTGGas, Water/Sanitary
04/05/2022———
04/05/2022——Water/Sanitary
25 jobs · most recent 07/22/2026
General Wiring
FiledStatusContractorScope
07/22/2026CompleteEMPIRE LIC ELECL CONTRS—
05/10/2026CompleteATMOS ELECTRIC SVCE CORPGeneral Wiring
01/06/2026Permit IssuedVALENTIS ELECTRIC, INC.General Wiring
10/15/2025CompleteAMSTERDAM ELECTRIC CORPGeneral Wiring
09/18/2025CompleteHESO ELECTRICAL INCGeneral Wiring
08/19/2025Permit IssuedBOROWIDE ELECT'L CONTR'S—
07/29/2025Permit IssuedALLSTATE ELEC'L CONT INCGeneral Wiring
05/02/2025CompletePOWER CONTROL ELEC CORPGeneral Wiring
01/03/2025CompleteAURORA ELECL CONTG INC—
12/02/2024Permit IssuedJ.A. LEE ELEC SVCS LLCGeneral Wiring
10/24/2024CompleteATMOS ELECTRIC SVCE CORP—
09/13/2024CompleteELECTL CONTG SOLUTIONS COGeneral Wiring
07/31/2024CompleteJ.A. LEE ELEC SVCS LLC263 meters, 1 new_meters
05/16/2024CompleteUS1 ELECTRIC CORPGeneral Wiring
05/02/2024Permit IssuedUS1 ELECTRIC CORPGeneral Wiring
1 job · most recent 04/16/2025
FiledStatusContractorScope
04/16/2025Permit IssuedA W R GROUP INC1 scope_items
1 job · most recent 08/22/2025
Sidewalk Shed
FiledStatusContractorScope
08/22/2025Permit IssuedANDAMIO SCAFFOLDING LLCSidewalk Shed
5 jobs · most recent 07/22/2026
Tenant Protection Plan 72 Hour Suspended Scaffold
FiledStatusContractorScope
07/22/2026Permit IssuedDO RITE MECHANICAL CORPTenant Protection Plan 72 Hour
05/13/2026Permit IssuedA W R GROUP INCSuspended Scaffold
02/20/2026Signed-offGRAMERCY RENOVATION &Tenant Protection Plan 72 Hour
04/05/2022——Tenant Protection Plan 72 Hour
04/05/2022——Tenant Protection Plan 72 Hour
1 job · most recent 05/13/2026
Suspended Scaffold (SC)
FiledStatusContractorScope
05/13/2026Permit IssuedA W R GROUP INCSuspended Scaffold (SC)
Building Lifecycle
All (300)Filed (57)Permit Issued (50)Signed Off (22)Facade (FISP) (15)Violation (56)Inspection (28)Objection (42)Special Inspection (30)
09/15/2026
Permit issued — General Construction
M01207560-I1-ST
09/14/2026
Permit issued — Plumbing
M01160573-S1-PL
08/13/2026
Permit issued — Sidewalk Shed
M01275306-I1-SH
08/10/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/31/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/27/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/22/2026
Filed — Alteration
COMBINATION OF APARTMENTS & INTERIOR RENOVATIONS OF APARTMENTS 10N & 10P IN COMPLIANCE WITH TPPN #3/1997. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
M01160573-S1
07/14/2026
Filed — Alteration
COMBINATION OF APARTMENTS & INTERIOR RENOVATIONS OF APARTMENTS 10N & 10P IN COMPLIANCE WITH TPPN #3/1997. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
M01160573-P1
07/10/2026
Filed — Alteration
INSTALLATION OF TEMPORARY PROTECTION AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY SHALL COMPLY WITH CHAPTER#33 OF 2022 THE NY BUILDING CODE.
M01427631-I1
07/10/2026
Permit issued — Protection and Mechanical Methods
M01427631-I1-PMM
06/15/2026
Signed off — Alteration
Non-structural partition demolition & new partition construction to relocate the bedroom in a 1-bedroom apt. Renovation & expansion of bathroom & kitchenette. New flooring, lighting, electrical. New PTAC units. No change in use, egress or occupancy
M01232673-I1
06/08/2026
Permit issued — General Construction
M01207560-I1-GC
06/08/2026
Permit issued — Suspended Scaffold
M01279346-I1-SC
06/05/2026
Permit issued — General Construction
M01160573-I1-GC
06/03/2026
Permit issued — General Construction
M01160573-I1-GC
05/27/2026
Special inspection requirement — Post-installed Anchors
Karol Zdancewicz
05/27/2026
Special inspection requirement — Alternative Materials - OTCR Buildings Bulletin Number
Karol Zdancewicz
05/13/2026
Filed — Alteration
Installation of suspended scaffold for facade inspection/repair.
M01279346-P2
05/08/2026
Special inspection requirement — Alternative Materials - OTCR Buildings Bulletin Number
Karol Zdancewicz
05/08/2026
Special inspection requirement — Post-installed Anchors
Karol Zdancewicz
04/24/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/12/2026
Filed — Alteration
INSTALL , RELOCATE AND REPLACE NEW PLUMBING FIXTURES IN CONJUNCTION WITH THE INTERIOR RENOVATION OF APARTMENT #2E ON THE SECOND FLOOR FILED UNDER APPLICATION M01075784-I1. NO CHANGE IN USE EGRESS OR OCCUPANCY.
M01168299-P1
03/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
ARIEL GOLSHAN
03/02/2026
Special inspection requirement — Lighting controls
ARIEL GOLSHAN
03/02/2026
Special inspection requirement — Interior lighting power
ARIEL GOLSHAN
03/02/2026
Special inspection requirement — Fire-Resistance Rated Construction
ARIEL GOLSHAN
03/02/2026
Special inspection requirement — HVAC-R and service water heating equipment
ARIEL GOLSHAN
03/02/2026
Special inspection requirement — Tenant Protection Plan Compliance
ARIEL GOLSHAN
03/02/2026
Special inspection requirement — Energy Code Compliance Inspections
ARIEL GOLSHAN
03/02/2026
Special inspection requirement — Lighting in dwelling units
ARIEL GOLSHAN
03/02/2026
Special inspection requirement — Mechanical Systems
ARIEL GOLSHAN
03/02/2026
Special inspection requirement — Final
JONATHAN HELD
02/20/2026
Filed — Alteration
Non-structural partition demolition & new partition construction to relocate the bedroom in a 1-bedroom apt. Renovation & expansion of bathroom & kitchenette. New flooring, lighting, electrical. New PTAC units. No change in use, egress or occupancy
M01232673-P1
02/19/2026
Filed — Alteration
M01168287-P1
02/14/2026
Signed off — Alteration
FILE TEMPORARY CONSTRUCTION FENCE AS SHOWN ON THE PLAN. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
M00945407-I1
11/24/2025
Permit issued — General Construction
M01232673-I1-GC-CX
11/19/2025
Signed off — Alteration
COMBINE ADJACENT APARTMENTS 7N AND 7P ON 7TH FLOOR IN CO-OP BUILDING. NO CHANGE TO USE,OCCUPANCY OR EGRESS AS PER TPPN #3/97.
M01173205-I1
11/19/2025
Signed off — Alteration
COMBINE ADJACENT APARTMENTS 7N AND 7P ON 7TH FLOOR IN CO-OP BUILDING. NO CHANGE TO USE,OCCUPANCY OR EGRESS AS PER TPPN #3/97.
M01173205-S1
11/15/2025
Special inspection requirement — Final
JONATHAN HELD
11/15/2025
Special inspection requirement — Energy Code Compliance Inspections
ARIEL GOLSHAN
11/15/2025
Special inspection requirement — Tenant Protection Plan Compliance
ARIEL GOLSHAN
11/15/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ARIEL GOLSHAN
11/15/2025
Special inspection requirement — Interior lighting power
ARIEL GOLSHAN
11/15/2025
Special inspection requirement — Lighting controls
ARIEL GOLSHAN
11/15/2025
Special inspection requirement — HVAC-R and service water heating equipment
ARIEL GOLSHAN
11/15/2025
Special inspection requirement — Lighting in dwelling units
ARIEL GOLSHAN
11/15/2025
Special inspection requirement — Fire-Resistance Rated Construction
ARIEL GOLSHAN
11/15/2025
Special inspection requirement — Mechanical Systems
ARIEL GOLSHAN
11/13/2025
Permit issued — General Construction
M01160573-I1-GC
10/27/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/23/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/21/2025
Filed — Alteration
Installation of suspended scaffold for facade inspection/repair.
M01279346-P1
10/21/2025
Special inspection requirement — Alternative Materials - OTCR Buildings Bulletin Number
Karol Zdancewicz
10/21/2025
Special inspection requirement — Post-installed Anchors
Karol Zdancewicz
10/09/2025
Permit issued — Plumbing
M01168299-I1-PL
10/03/2025
Permit issued — General Construction
M01232673-I1-GC-CX
09/29/2025
Permit issued — General Construction
M01207560-I1-GC
09/25/2025
Objection resolved — Addressed
09/19/2025
Objection resolved — Addressed
09/19/2025
Objection resolved — Addressed
Latest 60 of 300 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
FIRSTSERVICE RESIDENTIAL107/11/2026
GETIR US INC.1103/22/2026
301 EAST 22ND STREET TENANT5003/22/2026
DNA CONTRACTING103/22/2026
GOODSTEIN MANAGEMENT1403/22/2026
301 E 22 ST TENANT CORP2503/22/2026
OWNER OF 390 2 AVE203/22/2026
MCFAR CONSTRACTORS INC103/22/2026
301 EAST 22 OWNERS303/21/2026
301E22 TENANTS CORP %GOODSTEIN M303/21/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KENNY LEE ARCHITECT103/21/2026
I L CONSULTING803/21/2026
JONATHAN B. HELD A.I.A.203/21/2026
Rigid Structural Design, LLC203/21/2026
SYNERGY BUILDING CONSULTANTS203/21/2026
ARCHVISION DESIGN STUDIO103/21/2026
PS ENGINEERS403/21/2026
BERTOLINI ARCHITECTURAL WORKS DPC203/21/2026
ARINNITY NYC203/21/2026
DOMANI CONSULTING503/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUPERIOR FIRE CONTROL INCGeneral Contractor603/21/2026
STAR RENOVATIONS NY LTDGeneral Contractor603/21/2026
AJ MICHAELS CONTRACTING CGeneral Contractor603/21/2026
TRIBUTE RESTORATION INCGeneral Contractor304/09/2026
A W R GROUP INCGeneral Contractor309/16/2026
ANDAMIO SCAFFOLDING LLCGeneral Contractor308/26/2026
LIVOTI ENTERPRISE LLCGeneral Contractor303/21/2026
EDR CONST & MGMT INCGeneral Contractor307/08/2026
ORBIT PLBG & HTG INCPlumbing307/08/2026
MANHATTAN CONCRETE LLCGeneral Contractor303/21/2026
GRAMERCY RENOVATION &General Contractor204/09/2026
ROCKLEDGE SCAFFOLD CORPGeneral Contractor203/21/2026
JEPOL CONSTRUCTION INCGeneral Contractor203/21/2026
GENCO LEE RENOVATION INCGeneral Contractor207/08/2026
PRESTIGE TEAM WORK INCGeneral Contractor207/08/2026
J.A. LEE ELECTRIC INCGeneral Contractor107/08/2026
JOSE A SALAZAR-DELAROSAGeneral Contractor107/08/2026
MARPRO CONSTRUCTION CORPGeneral Contractor104/09/2026
NEW GENERATION CONTRACTINGeneral Contractor107/08/2026
AAA TOTAL PLUMBING, INCPlumbing107/08/2026
DO RITE MECHANICAL CORPPlumbing109/15/2026
HYDROKINETIC PLBG & HTG IPlumbing107/08/2026
INNOVATION PLUMBING LLCPlumbing107/08/2026
JOHN FITZGERALD PLBG &HTGPlumbing107/08/2026
NEW YORK PARK PLBG&HTG COPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
KZ ENGINEERING, P.C.4665305/13/2026
AG ENGINEERING PLLC8899202/20/2026
GEIGER ENGINEERING. PC689202/19/2026
HOWARD L ZIMMERMAN ARCHIT1712104/16/2025
PAUL CHRISTAKOS ARCHITECT5894201/29/2025
SCHERER DESIGN GROUP7921107/29/2024
RAND ENGINEERING & ARCHIT266107/26/2024
AMP ARCHITECTURE, PLLC6889301/22/2024
SOTIR ASSOCIATES7473510/11/2023
ATLAS ATC ENGINEERING INC8011106/28/2023
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedA W R GROUP INC09/15/2026
DOB NOWPlumbingPermit IssuedDO RITE MECHANICAL CORP09/14/2026
DOB NOWSidewalk ShedPermit IssuedANDAMIO SCAFFOLDING LLC08/13/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedANDAMIO SCAFFOLDING LLC07/10/2026
DOB NOWGeneral ConstructionPermit IssuedA W R GROUP INC06/08/2026
DOB NOWSuspended ScaffoldPermit IssuedA W R GROUP INC06/08/2026
DOB NOWGeneral ConstructionPermit IssuedEDR CONST & MGMT INC06/05/2026
DOB NOWGeneral ConstructionPermit IssuedEDR CONST & MGMT INC06/03/2026
DOB NOWGeneral ConstructionSigned-offGRAMERCY RENOVATION &11/24/2025
DOB NOWGeneral ConstructionPermit IssuedEDR CONST MGMT11/13/2025
DOB NOWPlumbingPermit IssuedJOHN FITZGERALD PLBG &HTG10/09/2025
DOB NOWGeneral ConstructionSigned-offGRAMERCY RENOVATION &10/03/2025
DOB NOWGeneral ConstructionPermit IssuedA W R GROUP INC09/29/2025
DOB NOWSuspended ScaffoldPermit IssuedA W R GROUP INC09/04/2025
DOB NOWSidewalk ShedPermit IssuedANDAMIO SCAFFOLDING LLC08/25/2025
DOB NOWGeneral ConstructionPermit IssuedNEW GENERATION CONTRACTIN06/04/2025
DOB NOWPlumbingSigned-offPEAK PLUMBING SOLUTIONS L04/02/2025
DOB NOWGeneral ConstructionSigned-offMARPRO CONSTRUCTION CORP03/05/2025
DOB NOWSuspended ScaffoldSigned-offTRIBUTE RESTORATION INC02/10/2025
DOB NOWMechanical SystemsSigned-offHUDSON MERIDIAN CONST GP01/03/2025
DOB NOWSidewalk ShedSigned-offINTERSYSTEMS INSTAL S&S12/23/2024
DOB NOWSignSigned-offUNITECH DESIGN INC10/15/2024
DOB NOWAntennaSigned-offMIC GEN'L CONTRACTING INC10/03/2024
DOB NOWAntennaSigned-offLIVOTI ENTERPRISE LLC09/20/2024
DOB NOWGeneral ConstructionSigned-offTRIBUTE RESTORATION INC03/19/2024
DOB NOWPlumbingSigned-offORBIT PLBG & HTG INC02/01/2024
DOB NOWGeneral ConstructionPermit IssuedPRESTIGE TEAM WORK INC01/12/2024
DOB NOWConstruction FenceSigned-offTRIBUTE RESTORATION INC11/09/2023
DOB NOWGeneral ConstructionSigned-offSTAR RENOVATIONS NY LTD07/14/2023
DOB NOWPlumbingPermit IssuedINNOVATION PLUMBING LLC06/15/2023
DOB NOWPlumbingSigned-offHYDROKINETIC PLBG & HTG I04/15/2023
DOB NOWGeneral ConstructionSigned-offSTAR RENOVATIONS NY LTD04/13/2023
DOB NOWPlumbingSigned-offORBIT PLBG & HTG INC02/02/2023
DOB NOWGeneral ConstructionPermit IssuedPRESTIGE TEAM WORK INC12/23/2022
DOB NOWGeneral ConstructionSigned-offSUPERIOR FIRE CONTROL INC12/22/2022
DOB NOWMechanical SystemsSigned-offSUPERIOR FIRE CONTROL INC12/22/2022
DOB NOWPlumbingSigned-offNEW YORK PARK PLBG&HTG CO12/16/2022
DOB NOWGeneral ConstructionSigned-offD.S.C.CONSTRUCTION INC12/14/2022
DOB NOWGeneral ConstructionPermit IssuedJOSE A SALAZAR-DELAROSA07/13/2022
DOB NOWGeneral ConstructionSigned-offAJ MICHAELS CONTRACTING C06/28/2022
+ 60 more permits on file
▾Field Inspections (DOB CAP) — 28
DateTypeResultReport
08/10/2026Pass-Final CND-Occupancy InspectionPassView ↗
07/31/2026Pass-Final CND-Occupancy InspectionPassView ↗
07/27/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/24/2026Pass-Final CND-Occupancy InspectionPassView ↗
10/27/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/23/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/17/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
09/17/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/21/2025Pass-Final CND-Occupancy InspectionPassView ↗
06/18/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/26/2024Pass-Final Sign Permit InspectionPassView ↗
02/12/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/09/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/06/2024Pass-Final CND-Occupancy InspectionPassView ↗
01/31/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/22/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/20/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/10/2023Pass-Final CND-Occupancy InspectionPassView ↗
06/26/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/05/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/10/2023Pass-Final CND-Occupancy InspectionPassView ↗
04/25/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/21/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/18/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/10/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
Latest 25 of 28.
▾Special Inspection Requirements (DOB NOW) — 145
DateRequirementInspectorRole
05/27/2026Post-installed AnchorsKarol Zdancewiczspecial
05/27/2026Alternative Materials - OTCR Buildings Bulletin NumberKarol Zdancewiczspecial
05/08/2026Alternative Materials - OTCR Buildings Bulletin NumberKarol Zdancewiczspecial
05/08/2026Post-installed AnchorsKarol Zdancewiczspecial
03/02/2026HVAC-R and service water heating equipmentARIEL GOLSHANenergy_progress
03/02/2026FinalJONATHAN HELDprogress
03/02/2026Energy Code Compliance InspectionsARIEL GOLSHANprogress
03/02/2026Fire-Resistance Rated ConstructionARIEL GOLSHANprogress
03/02/2026Fire-Resistant Penetrations and JointsARIEL GOLSHANspecial
03/02/2026Tenant Protection Plan ComplianceARIEL GOLSHANspecial
03/02/2026Mechanical SystemsARIEL GOLSHANspecial
03/02/2026Lighting controlsARIEL GOLSHANenergy_progress
03/02/2026Lighting in dwelling unitsARIEL GOLSHANenergy_progress
03/02/2026Interior lighting powerARIEL GOLSHANenergy_progress
11/15/2025Lighting in dwelling unitsARIEL GOLSHANenergy_progress
11/15/2025Fire-Resistant Penetrations and JointsARIEL GOLSHANspecial
11/15/2025Mechanical SystemsARIEL GOLSHANspecial
11/15/2025Tenant Protection Plan ComplianceARIEL GOLSHANspecial
11/15/2025Energy Code Compliance InspectionsARIEL GOLSHANprogress
11/15/2025FinalJONATHAN HELDprogress
11/15/2025Fire-Resistance Rated ConstructionARIEL GOLSHANprogress
11/15/2025Interior lighting powerARIEL GOLSHANenergy_progress
11/15/2025Lighting controlsARIEL GOLSHANenergy_progress
11/15/2025HVAC-R and service water heating equipmentARIEL GOLSHANenergy_progress
10/21/2025Alternative Materials - OTCR Buildings Bulletin NumberKarol Zdancewiczspecial
Latest 25 of 145.
▾Documents — 760 on file (BIS + DOB NOW)
▸Plans & Drawings58
▸DOB NOWPlans/Sketch56
09/03/2026M00557017-I1Contact architect ↗
09/03/2026M00526028-I1Contact architect ↗
09/02/2026M00511252-P1Contact architect ↗
Showing 3 of 56 on file for this type
▸DOB NOWPlans/Sketch - Plumbing1
09/05/2026M00327373-I1Contact architect ↗
▸DOB NOWPlans/Sketch - Sidewalk Shed1
09/04/2026M00460715-I1Contact architect ↗
▸Applications & Permits116
▸BISPLAN / WORK APPROVAL APPLICATION57
03/15/2021140999463Open ↗
04/08/2020140894628Open ↗
04/01/2020140894628Open ↗
Showing 3 of 57 on file for this type
▸BISWORK PERMIT APPLICATION57
04/19/2021123700030Open ↗
06/26/2020140894628Open ↗
06/22/2020140894628Open ↗
Showing 3 of 57 on file for this type
▸BISApplication Withdrawal/Address Change Form OP-1132
10/23/2018120289311Open ↗
10/15/2018120289311Open ↗
▸Seals & Professional Certifications220
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION55
03/06/2020123693770Open ↗
01/22/2020123700030Open ↗
11/14/2019123705856Open ↗
Showing 3 of 55 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature54
09/05/2026M00327373-I1Open ↗
09/03/2026M00526028-I1Open ↗
09/03/2026M00620434-I1Open ↗
Showing 3 of 54 on file for this type
▸DOB NOWProgress Inspector Seal & Signature53
09/28/2026M00511220-I1Open ↗
09/28/2026M00511220-I1Open ↗
09/28/2026M00511220-I1Open ↗
Showing 3 of 53 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature33
09/28/2026M00511220-I1Open ↗
09/25/2026M08038681-I1Open ↗
09/23/2026M01232673-I1Open ↗
Showing 3 of 33 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST8
05/23/2019123779330Open ↗
Showing 1 of 8 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM6
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT4
03/15/2021140999463Open ↗
05/23/2019123779330Open ↗
03/08/2017140614716Open ↗
Showing 3 of 4 on file for this type
▸BISAPPLICANT OWNER SIGNATURE3
04/01/2020140894628Open ↗
08/07/2018140790455Open ↗
Showing 2 of 3 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
03/15/2021140999463Open ↗
03/08/2017140614716Open ↗
▸BISPC FULL REPORT1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
03/08/2017140614716Open ↗
▸Trade Schedules & Equipment44
▸BISSELF-CERT PLUMBING NOTICE14
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 14 on file for this type
▸BISSCHEDULE B - PLUMBING12
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 12 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE11
07/29/2019123705856Open ↗
05/01/2019123705856Open ↗
12/21/2017122853493Open ↗
Showing 3 of 11 on file for this type
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT3
05/02/2018122853493Open ↗
02/28/2017122853493Open ↗
Showing 2 of 3 on file for this type
▸BISSPRINKLER INSP REPORT : FP-852
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISEQUIPMENT USE PERMITS1
08/06/2019123779330Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT1
08/06/2019123779330Open ↗
▸Safety & Tenant Protection10
▸BISTenant Protection Plan and Notes8
04/13/2020140894628Open ↗
01/22/2020123700030Open ↗
08/19/2019123693770Open ↗
Showing 3 of 8 on file for this type
▸BISTPP1: TENANT PROTECTION PLAN1
03/15/2021140999463Open ↗
▸DOB NOWTenant Protection Plan1
09/05/2026M00327373-I1Open ↗
▸Environmental & Asbestos75
▸DOB NOWDEP ACP-5: Asbestos Assessment Report42
09/05/2026M00327373-I1Open ↗
09/03/2026M00526028-I1Open ↗
09/01/2026M00758956-I1Open ↗
Showing 3 of 42 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)11
04/01/2020140894628Open ↗
01/22/2020123700030Open ↗
08/19/2019123693770Open ↗
Showing 3 of 11 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'8
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 8 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER7
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 7 on file for this type
▸BISDEP ASBESTOS PROJECT COMPLETION FORM2
05/08/2019123705856Open ↗
Showing 1 of 2 on file for this type
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form2
08/25/2026M01168287-I1Open ↗
Showing 1 of 2 on file for this type
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP 20-21-5)1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Energy Compliance45
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS17
03/06/2020123693770Open ↗
01/22/2020123700030Open ↗
09/13/2019123693770Open ↗
Showing 3 of 17 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS10
03/06/2020123693770Open ↗
11/14/2019123705856Open ↗
08/07/2019123779330Open ↗
Showing 3 of 10 on file for this type
▸BISTR8: Energy Code Progress Inspections6
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 6 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY4
01/28/2021140894628Open ↗
04/16/2020140894628Open ↗
04/01/2020140894628Open ↗
Showing 3 of 4 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS (EN2)2
10/11/2022123700030Open ↗
01/28/2021140894628Open ↗
▸DOB NOWEN2: As Built Energy Analysis.2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISAIR SEALING AND INSULATION - VISUAL1
10/11/2022123700030Open ↗
▸BISPRELIMINARY COMMISSIONING REPORT CERTIFICATION1
11/15/2018122853493Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
10/11/2022123700030Open ↗
▸BISTECHNICAL REPORT: ENERGY1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Inspections & Test Reports7
▸BISTECHNICAL REPORT: RESPONSIBILITY7
10/08/2021123700030Open ↗
03/15/2021140999463Open ↗
01/28/2021140894628Open ↗
Showing 3 of 7 on file for this type
▸Approvals, Objections & Sign-offs55
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST22
10/11/2022123700030Open ↗
01/28/2021140894628Open ↗
03/06/2020123693770Open ↗
Showing 3 of 22 on file for this type
▸BISADMINISTRATIVE OBJECTIONS15
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 15 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION12
11/20/2018122853493Open ↗
08/06/2018120289311Open ↗
05/24/2017122608561Open ↗
Showing 3 of 12 on file for this type
▸BISSUPERSEDING LETTER3
06/26/2020140894628Open ↗
Showing 1 of 3 on file for this type
▸BISFINAL1
10/11/2022123700030Open ↗
▸BISSHED LETTER1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISCCD1-Construction Code Determination1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Cost, Insurance & Ownership47
▸BISCOST AFFIDAVIT42
03/15/2021140999463Open ↗
04/01/2020140894628Open ↗
03/06/2020123693770Open ↗
Showing 3 of 42 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT3
06/16/2020140894628Open ↗
Showing 1 of 3 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW32
10/11/2022123700030Open ↗
01/28/2021140894628Open ↗
▸Filing & Intake Forms64
▸BISEFILING COVER SHEET24
01/22/2020123700030Open ↗
08/19/2019123693770Open ↗
05/23/2019123779330Open ↗
Showing 3 of 24 on file for this type
▸BISADDITIONAL INFORMATION20
04/23/2020140894628Open ↗
04/16/2020140894628Open ↗
04/13/2020140894628Open ↗
Showing 3 of 20 on file for this type
▸BISBOROUGH INTAKE FORM15
03/06/2020123693770Open ↗
11/14/2019123705856Open ↗
08/07/2019123779330Open ↗
Showing 3 of 15 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET5
03/15/2021140999463Open ↗
04/01/2020140894628Open ↗
08/07/2018140790455Open ↗
Showing 3 of 5 on file for this type
▸Other Documents17
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION7
04/20/2017123029365Open ↗
Showing 1 of 7 on file for this type
▸DOB NOWManufacturer's Specifications4
08/21/2026M01279346-P2Open ↗
08/13/2026M01279346-P1Open ↗
08/13/2026M01279346-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWCalculations4
08/21/2026M01279346-P2Open ↗
08/13/2026M01279346-I1Open ↗
08/13/2026M01279346-P1Open ↗
Showing 3 of 4 on file for this type
▸BISSupporting Document: Fee Exempt1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type