← Back
Two family converted from one family
382 GRAND CONCOURSE
BRONX · BIN 2001007
💬 Discuss this project
1901Year Built
3Stories
B3Building Class
C4-4Zoning
3,156 sfGross Floor Area
2Units
Two family converted from one family · 2,131 sf lot · 1.48 FAR built · Flood zone X500
Locations of Work
ArchitecturePlumbing
Floor 21p · 1 filing · 6 docs
Floor 1
Basement1p · 1 filing · 6 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/02/2021$325K—— → —$103/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LEDER-LUIS ARCHITECTURAL DESIGN, PL304/03/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
XPDITE GROUP LLC (104)303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SARDAR RESTORATION CORPGeneral Contractor107/08/2026
JOHN FITZGERALD PLBG &HTGPlumbing107/08/2026
Building Lifecycle
All (18)Filed (3)Permit Issued (2)Signed Off (2)Inspection (5)Objection (6)
09/25/2023
Signed off — Alteration
Construction work to renovate existing two family dwelling
X00696654-I1
09/22/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
04/13/2023
Signed off — Alteration
Plumbing work in conjunction with application #X00696654- to renovate existing two family dwelling
X00696682-I1
04/06/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/06/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
04/03/2023
Filed — Alteration
Plumbing work in conjunction with application #X00696654- to renovate existing two family dwelling
X00696682-P1
03/31/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/25/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/18/2022
Permit issued — Plumbing
X00696682-I1-PL
10/18/2022
Permit issued — General Construction
X00696654-I1-GC
06/10/2022
Filed — Alteration
Plumbing work in conjunction with application #X00696654- to renovate existing two family dwelling
X00696682-I1
05/13/2022
Objection raised — Cost
05/13/2022
Objection resolved — Addressed
05/13/2022
Objection raised — Energy
05/13/2022
Objection resolved — Addressed
05/13/2022
Objection raised — Admin
05/13/2022
Objection resolved — Addressed
05/02/2022
Filed — Alteration
Construction work to renovate existing two family dwelling
X00696654-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offJOHN FITZGERALD PLBG &HTG11/18/2022
DOB NOWGeneral ConstructionSigned-offSARDAR RESTORATION CORP10/18/2022
2 projects · most recent 02/07/2023
General Wiring
FiledStatusContractorScope
02/07/2023CompleteGILSTON BROTHERS ELECT'LGeneral Wiring
10/31/2022Permit IssuedJOSEPH WEINSTEIN ELECTRICGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
09/22/2023Pass-Final General Construction Non-Directive 14PassView ↗
04/06/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/06/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
03/31/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/25/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/24/2026X00696682-I1Request digital key ↗
08/24/2026X00696682-P1Request digital key ↗
08/15/2026X00696654-I1Request digital key ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/24/2026X00696654-I1Open ↗
08/13/2026X00696682-P1Open ↗
08/13/2026X00696682-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/15/2026X00696654-I1Open ↗
08/13/2026X00696682-P1Open ↗
08/13/2026X00696682-I1Open ↗