← Back
Two family brick
382 STERLING PLACE
BROOKLYN · BIN 3029376
💬 Discuss this project
1901Year Built
3Stories
B1Building Class
R6BZoning
3,756 sfGross Floor Area
2Units
Two family brick · Owner of record: 382 STERLING, LLC · 2,357 sf lot · 1.59 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanical
Floor 35p · 1 filing · 20 docs
Floor 24p · 1 filing · 20 docs
Floor 13p · 1 filing · 20 docs
Cellar4p · 1 filing · 20 docs
Basement3p · 1 filing · 20 docs
1 job · most recent 05/25/2023
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
05/25/2023Signed-offGAUDIOSO CONTRACTING INCAir Conditioning Systems
Cooling
Mitsubishi Electric SUZ-KA30NA2 30,000 BTU · Split System ×4
SUZ-KA12NA2 12,000 BTU · Split System ×1
1 job · most recent 03/14/2023
General Wiring HVAC Wiring
FiledStatusContractorScope
03/14/2023CompleteSUNBIRD ELECTRICAL CONTRGeneral Wiring, HVAC Wiring
Building Lifecycle
All (39)Filed (6)Permit Issued (5)Signed Off (2)Inspection (6)Special Inspection (20)
03/21/2024
Inspection — Fail-Final Construction Permit Withdrawal
Fail
View inspection ↗
08/08/2023
Signed off — Alteration CO
CONVERT FROM TWO TO ONE FAMILY. PARTITION AND MECHANICAL WORK. NEW REAR PORCH. REPLACE WINDOWS.
B00530988-S2
08/07/2023
Signed off — Alteration CO
CONVERT FROM TWO TO ONE FAMILY. PARTITION AND MECHANICAL WORK. NEW REAR PORCH. REPLACE WINDOWS.
B00530988-S1
07/21/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/12/2023
Special inspection requirement — HVAC-R and service water heating equipment
Sarah Jacoby
06/12/2023
Special inspection requirement — Lighting in dwelling units
Sarah Jacoby
06/12/2023
Special inspection requirement — Maintenance information
Sarah Jacoby
06/12/2023
Special inspection requirement — Air barrier - visual inspection
Sarah Jacoby
06/12/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Sarah Jacoby
06/12/2023
Special inspection requirement — HVAC-R and service water heating system controls
Sarah Jacoby
06/12/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
Sarah Jacoby
06/12/2023
Special inspection requirement — Fenestration areas
Sarah Jacoby
06/12/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Celin Munoz
06/12/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Sarah Jacoby
06/12/2023
Special inspection requirement — Mechanical Systems
Sarah Jacoby
06/12/2023
Special inspection requirement — Final
Sarah Jacoby
06/12/2023
Special inspection requirement — Energy Code Compliance Inspections
Sarah Jacoby
05/30/2023
Permit issued — Structural
B00530988-S2-ST
05/26/2023
Special inspection requirement — Post-installed Anchors
Celin Munoz
05/26/2023
Special inspection requirement — Structural Steel - Details
Celin Munoz
05/26/2023
Special inspection requirement — Structural Steel - High Strength Bolting
Celin Munoz
05/26/2023
Special inspection requirement — Structural Steel - Welding
Celin Munoz
05/26/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Celin Munoz
05/26/2023
Special inspection requirement — Final
Celin Munoz
05/26/2023
Special inspection requirement — Concrete - Cast-In-Place
Celin Munoz
05/25/2023
Filed — Alteration CO
CONVERT FROM TWO TO ONE FAMILY. PARTITION AND MECHANICAL WORK. NEW REAR PORCH. REPLACE WINDOWS.
B00530988-P3
05/18/2023
Filed — Alteration CO
CONVERT FROM TWO TO ONE FAMILY. PARTITION AND MECHANICAL WORK. NEW REAR PORCH. REPLACE WINDOWS.
B00530988-P2
05/16/2023
Permit issued — Mechanical Systems
B00530988-I1-GC-CX
04/21/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/12/2023
Inspection — No Access-Final PL - Up to 3 Requested Floors
No Access
View inspection ↗
03/31/2023
Filed — Alteration CO
CONVERT FROM TWO TO ONE FAMILY. PARTITION AND MECHANICAL WORK. NEW REAR PORCH. REPLACE WINDOWS.
B00530988-P1
02/23/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/21/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/18/2022
Permit issued — Mechanical Systems
B00530988-I1-GC-CX
12/10/2021
Permit issued — Plumbing
B00530988-S1-PL
10/27/2021
Permit issued — Mechanical Systems
B00530988-I1-GC-CX
10/01/2021
Filed — Alteration CO
CONVERT FROM TWO TO ONE FAMILY. PARTITION AND MECHANICAL WORK. NEW REAR PORCH. REPLACE WINDOWS.
B00530988-S2
09/10/2021
Filed — Alteration CO
CONVERT FROM TWO TO ONE FAMILY. PARTITION AND MECHANICAL WORK. NEW REAR PORCH. REPLACE WINDOWS.
B00530988-S1
07/28/2021
Filed — Alteration CO
CONVERT FROM TWO TO ONE FAMILY. PARTITION AND MECHANICAL WORK. NEW REAR PORCH. REPLACE WINDOWS.
B00530988-I1
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/21/2020$3.2M—Private party → 382 STERLING, LLC$840/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SARAH JACOBY ARCHITECT, DPC605/25/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JOSEPH FELLNER603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GAUDIOSO CONTRACTING INCGeneral Contractor707/08/2026
PLUMB-IT MECHANICAL INCPlumbing607/08/2026
DEMETRIOS ILIOPOULOSElectrical103/21/2026
SARAH JACOBYElectrical103/21/2026
SUNBIRD ELECTRICAL CONTRElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CELIN MUNOZ CONSULTING EN1064405/25/2023
SARAH JACOBY ARCHITECT5641205/18/2023
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offGAUDIOSO CONTRACTING05/30/2023
DOB NOWMechanical SystemsPermit IssuedGAUDIOSO CONTRACTING05/16/2023
DOB NOWMechanical SystemsPermit IssuedGAUDIOSO CONTRACTING05/18/2022
DOB NOWPlumbingSigned-offJVR PLBG AND HEATING INC12/10/2021
DOB NOWMechanical SystemsPermit IssuedGAUDIOSO CONTRACTING10/27/2021
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
03/21/2024Fail-Final Construction Permit WithdrawalFailView ↗
07/21/2023Pass-Final CND-Occupancy InspectionPassView ↗
04/21/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/12/2023No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
02/23/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/21/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 20
DateRequirementInspectorRole
06/12/2023HVAC-R and service water heating equipmentSarah Jacobyenergy_progress
06/12/2023Lighting in dwelling unitsSarah Jacobyenergy_progress
06/12/2023Maintenance informationSarah Jacobyenergy_progress
06/12/2023Air barrier - visual inspectionSarah Jacobyenergy_progress
06/12/2023HVAC-R and service water piping design and insulationSarah Jacobyenergy_progress
06/12/2023HVAC-R and service water heating system controlsSarah Jacobyenergy_progress
06/12/2023Fenestration and door U-factor and product ratingsSarah Jacobyenergy_progress
06/12/2023Fenestration areasSarah Jacobyenergy_progress
06/12/2023Structural Stability – Alterations of existing buildingsCelin Munozspecial
06/12/2023Fire-Resistant Penetrations and JointsSarah Jacobyspecial
06/12/2023Mechanical SystemsSarah Jacobyspecial
06/12/2023FinalSarah Jacobyprogress
06/12/2023Energy Code Compliance InspectionsSarah Jacobyprogress
05/26/2023Post-installed AnchorsCelin Munozspecial
05/26/2023Structural Steel - DetailsCelin Munozspecial
05/26/2023Structural Steel - High Strength BoltingCelin Munozspecial
05/26/2023Structural Steel - WeldingCelin Munozspecial
05/26/2023Structural Stability – Alterations of existing buildingsCelin Munozspecial
05/26/2023FinalCelin Munozprogress
05/26/2023Concrete - Cast-In-PlaceCelin Munozspecial
▾Documents — 47 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
09/01/2026B00530988-P3Request digital key ↗
09/01/2026B00530988-P2Request digital key ↗
09/01/2026B00530988-P1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits6
▸DOB NOWLPC Approval/Permit6
08/13/2026B00530988-S1Open ↗
08/13/2026B00530988-S2Open ↗
08/13/2026B00530988-I1Open ↗
Showing 3 of 6 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00530988-I1Open ↗
▸Seals & Professional Certifications24
▸DOB NOWSpecial Inspector Seal & Signature9
08/28/2026B00530988-S2Open ↗
08/28/2026B00530988-S2Open ↗
08/28/2026B00530988-S2Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWProgress Inspector Seal & Signature9
08/28/2026B00530988-S2Open ↗
08/25/2026B00530988-I1Open ↗
08/25/2026B00530988-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
09/01/2026B00530988-S1Open ↗
09/01/2026B00530988-P3Open ↗
09/01/2026B00530988-P2Open ↗
Showing 3 of 6 on file for this type
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
09/01/2026B00530988-P2Open ↗
09/01/2026B00530988-I1Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
09/01/2026B00530988-P3Open ↗
09/01/2026B00530988-P2Open ↗
09/01/2026B00530988-P1Open ↗
Showing 3 of 6 on file for this type
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026B00530988-I1Open ↗
08/13/2026B00530988-S1Open ↗