← Back
One story retail building
39-02 LITTLE NECK PARKWAY
QUEENS · Douglaston-Little Neck · BIN 4169876
💬 Discuss this project
1935Year Built
1Stories
K1Building Class
R2AZoning
1,400 sfGross Floor Area
1Units
One story retail building · Owner of record: ADAME CONSTRUCTION INC. · 5,366 sf lot · 0.26 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Floor 13p · 1 filing · 6 docs
Cellar4p · 1 filing · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ADAME CONSTRUCTION1407/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/07/2022$842K—— → —$601/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ONENINETYTHREE ARCHITECT P.C.212/15/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
5BOROUGH CONSUTING EXPEDITING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ADAME CONSTRUCTION, INCGeneral Contractor403/21/2026
TRIPLE CROWN PLBG&HTG INCPlumbing307/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
S&S CONCRETE & SOIL TESTI1008111/30/2022
Building Lifecycle
All (14)Filed (2)Permit Issued (5)Inspection (7)
09/01/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
04/04/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/31/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/28/2023
Permit issued — Plumbing
Q08019346-S1-PL
02/24/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/27/2023
Permit issued — Plumbing
Q08019346-S1-PL
01/20/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
01/17/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/17/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
01/11/2023
Permit issued — General Construction
Q08019346-I1-GC
12/29/2022
Permit issued — Plumbing
Q08019346-S1-PL
12/15/2022
Filed — Alteration
INTERIOR RENOVATION OF EXISTING COMMERCIAL SPACE, REPAIR FLOORS, DRYWALL, AND CEILING FINISHES, DOORS, TOILET PARTITIONS AND FIXTURE. INSTALL (2) SPLIT-UNIT HEATING & COOLING AIR-CONDITIONING UNITS. ALL AS PER PLANS, NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q08019346-S1
12/10/2022
Permit issued — General Construction
Q08019346-I1-GC
11/30/2022
Filed — Alteration
INTERIOR RENOVATION OF EXISTING COMMERCIAL SPACE, REPAIR FLOORS, DRYWALL, AND CEILING FINISHES, DOORS, TOILET PARTITIONS AND FIXTURE. INSTALL (2) SPLIT-UNIT HEATING & COOLING AIR-CONDITIONING UNITS. ALL AS PER PLANS, NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q08019346-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedTRIPLE CROWN PLBG&HTG INC03/28/2023
DOB NOWPlumbingPermit IssuedTRIPLE CROWN PLBG&HTG INC01/27/2023
DOB NOWGeneral ConstructionPermit IssuedADAME CONSTRUCTION, INC01/11/2023
DOB NOWPlumbingPermit IssuedTRIPLE CROWN PLBG&HTG INC12/29/2022
DOB NOWGeneral ConstructionPermit IssuedADAME CONSTRUCTION, INC12/10/2022
1 project · most recent 12/15/2022
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
12/15/2022Permit IssuedADAME CONSTRUCTION, INCHeating and Air Conditioning Systems
Heat / Cool
Daikin 2 SPLIT UNIT WITH HEAT PUMP(OUTDOOR) MODEL 3MXS24RMVJUA SERIAL #E030546, E028670 24,000 BTU · Heat Pump Outdoor ×2
1 project · most recent 12/15/2022
Water/Sanitary
FiledStatusContractorScope
12/15/2022Permit IssuedTRIPLE CROWN PLBG&HTG INCWater/Sanitary
1 project · most recent 12/21/2022
General Wiring
FiledStatusContractorScope
12/21/2022CompleteINFINITI ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
09/01/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
04/04/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/31/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/24/2023Pass-Final CND-Occupancy InspectionPassView ↗
01/20/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
01/17/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/17/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Tenants in the building
TenantSpaceFloorsRenovation projects
True NorthRetailCellar, Floor 1
Project Q08019346 Alteration · Permit Issued · 11/30/2022
Read from each project’s drawing title blocks and cover sheets and checked twice; a name appears only when it is the occupant, never the owner, landlord or designer.
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/25/2026Q08019346-S1Request digital key ↗
08/25/2026Q08019346-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/25/2026Q08019346-S1Open ↗
08/25/2026Q08019346-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/25/2026Q08019346-S1Open ↗
08/25/2026Q08019346-I1Open ↗