Two family brick
39-60 50 STREET
QUEENS · Sunnyside · BIN 4001038
💬 Discuss this project
1920Year Built
2Stories
B1Building Class
R5BZoning
1,830 sfGross Floor Area
2Units
0 Open Violations
Two family brick · Owner of record: KB WOODSIDE LLC · 1,900 sf lot · 0.96 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/05/2022$1.5M—— → —$836/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ENTHINK ENGINEERS LLC312/14/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
H-BUILDER INCGeneral Contractor303/21/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ENTHINK ENGINEERS LLC6247312/14/2022
Building Lifecycle
All (17)Filed (3)Permit Issued (2)Signed Off (2)Violation (2)Inspection (5)Special Inspection (3)
03/17/2023
Signed off — Alteration
FILING FOR PLUMBING WORK TYPE FOR THE INTERIOR RENOVATION AT 1ST FLOOR AND CELLAR OF AN EXISTING TWO-STORY BUILDING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00798315-I1
03/17/2023
Signed off — Alteration
Q00793664-I1
02/27/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
01/06/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/06/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
12/27/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/15/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Sunil Saigal
12/14/2022
Filed — Alteration
FILING FOR PLUMBING WORK TYPE FOR THE INTERIOR RENOVATION AT 1ST FLOOR AND CELLAR OF AN EXISTING TWO-STORY BUILDING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00798315-P1
10/06/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/08/2022
Permit issued — Plumbing
Q00798315-I1-PL
08/30/2022
Filed — Alteration
FILING FOR PLUMBING WORK TYPE FOR THE INTERIOR RENOVATION AT 1ST FLOOR AND CELLAR OF AN EXISTING TWO-STORY BUILDING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00798315-I1
08/29/2022
Permit issued — General Construction
Q00793664-I1-GC
08/21/2022
Filed — Alteration
Q00793664-I1
08/15/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Sunil Saigal
08/15/2022
Special inspection requirement — Fire-Resistance Rated Construction
Sunil Saigal
08/06/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/12/1999
Violation issued (ECB, closed)
Plumbing
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAMERICAN STANDARD P&H CORORP.09/08/2022
DOB NOWGeneral ConstructionSigned-offH-BUILDER INC08/29/2022
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
02/27/2023Pass-Final General Construction Non-Directive 14PassView ↗
01/06/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/06/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
12/27/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/06/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
12/15/2022Fire-Resistant Penetrations and JointsSunil Saigalspecial
08/15/2022Fire-Resistant Penetrations and JointsSunil Saigalspecial
08/15/2022Fire-Resistance Rated ConstructionSunil Saigalprogress
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/25/2026Q00793664-I1Request digital key ↗
08/25/2026Q00798315-P1Request digital key ↗
08/25/2026Q00798315-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/25/2026Q00793664-I1Open ↗
08/25/2026Q00798315-I1Open ↗
08/13/2026Q00798315-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026Q00793664-I1Open ↗
09/01/2026Q00798315-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
09/01/2026Q00793664-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/25/2026Q00793664-I1Open ↗
08/25/2026Q00798315-I1Open ↗
08/13/2026Q00798315-P1Open ↗