← Back
Two stories - detached, small or mid-size
39 DETROIT AVENUE
STATEN ISLAND · Great Kills-Eltingville · BIN 5077184
💬 Discuss this project
1965Year Built
2Stories
A1Building Class
R3AZoning
2,120 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 10,000 sf lot · 0.21 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 25p · 2 filings · 20 docs
Floor 15p · 2 filings · 20 docs
Cellar4p · 1 filing · 7 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
STEPHAN R THIMME ARCHITECT PC412/20/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CLARKE CONSTRUCTION CONSULTANTS403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MAR-CEL RENOVATION LLCGeneral Contractor303/21/2026
M.A.C. PLUMBING, INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
STEPHAN R THIMME ARCHITEC3696412/20/2021
LAWRENCE SHACTEL. PE1496102/19/2021
Building Lifecycle
All (39)Filed (4)Permit Issued (2)Signed Off (2)Objection (12)Special Inspection (19)
02/14/2022
Signed off — Alteration
ALTERATION TYPE II: REMOVAL AND CONSTRUCTION OF NON-LOAD-BEARING PARTITIONS AND CEILINGS, ALL AT CELLAR, 1 ST AND 2 ND FLOOR OF 39 DETROIT AVENUE FILED IN CONJUNCTION WITH DOB NOW PL FILING. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
S00466885-I1
02/08/2022
Signed off — Alteration
PL FIXTURES FILED IN CONJUNCTION WITH DOB NOW GC FILING. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
S00468263-I1
01/03/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
stephan thimme
01/03/2022
Special inspection requirement — Energy Code Compliance Inspections
stephan thimme
01/03/2022
Special inspection requirement — Energy Code Compliance
stephan thimme
12/20/2021
Filed — Alteration
PL FIXTURES FILED IN CONJUNCTION WITH DOB NOW GC FILING. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
S00468263-P2
12/20/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
stephan thimme
12/20/2021
Special inspection requirement — Energy Code Compliance
stephan thimme
12/20/2021
Special inspection requirement — Energy Code Compliance Inspections
stephan thimme
10/29/2021
Filed — Alteration
PL FIXTURES FILED IN CONJUNCTION WITH DOB NOW GC FILING. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
S00468263-P1
10/29/2021
Special inspection requirement — Energy Code Compliance
stephan thimme
10/29/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
stephan thimme
10/29/2021
Special inspection requirement — Energy Code Compliance Inspections
stephan thimme
05/10/2021
Permit issued — Plumbing
S00468263-I1-PL
04/08/2021
Permit issued — General Construction
S00466885-I1-GC
03/02/2021
Objection raised — Inspections
03/02/2021
Objection resolved — Addressed
03/02/2021
Objection raised — Admin
03/02/2021
Objection resolved — Addressed
03/02/2021
Objection raised — Scope
03/02/2021
Objection resolved — Addressed
03/02/2021
Objection raised — Other
03/02/2021
Objection resolved — Addressed
03/02/2021
Objection raised — Scope
03/02/2021
Objection resolved — Addressed
02/24/2021
Objection raised — Scope
02/24/2021
Objection resolved — Addressed
02/19/2021
Filed — Alteration
ALTERATION TYPE II: REMOVAL AND CONSTRUCTION OF NON-LOAD-BEARING PARTITIONS AND CEILINGS, ALL AT CELLAR, 1 ST AND 2 ND FLOOR OF 39 DETROIT AVENUE FILED IN CONJUNCTION WITH DOB NOW PL FILING. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
S00466885-I1
02/19/2021
Filed — Alteration
PL FIXTURES FILED IN CONJUNCTION WITH DOB NOW GC FILING. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
S00468263-I1
02/16/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
stephan thimme
02/12/2021
Special inspection requirement — Lighting in dwelling units
stephan thimme
02/12/2021
Special inspection requirement — Energy Code Compliance
stephan thimme
02/12/2021
Special inspection requirement — Energy Code Compliance Inspections
stephan thimme
02/12/2021
Special inspection requirement — Fenestration air leakage
stephan thimme
02/12/2021
Special inspection requirement — Fenestration areas
stephan thimme
02/12/2021
Special inspection requirement — Air barrier - visual inspection
stephan thimme
02/12/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
stephan thimme
02/12/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
LAWRENCE SHACTEL
02/08/2021
Special inspection requirement — Final
stephan thimme
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offM.A.C. PLUMBING, INC05/10/2021
DOB NOWGeneral ConstructionSigned-offMAR-CEL RENOVATION LLC04/08/2021
1 project · most recent 05/12/2021
General Wiring
FiledStatusContractorScope
05/12/2021CompleteLUME ELECTRIC INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 19
DateRequirementInspectorRole
01/03/2022Fire-Resistant Penetrations and Jointsstephan thimmespecial
01/03/2022Energy Code Compliance Inspectionsstephan thimmeprogress
01/03/2022Energy Code Compliancestephan thimmeprogress
12/20/2021Fire-Resistant Penetrations and Jointsstephan thimmespecial
12/20/2021Energy Code Compliancestephan thimmeprogress
12/20/2021Energy Code Compliance Inspectionsstephan thimmeprogress
10/29/2021Energy Code Compliancestephan thimmeprogress
10/29/2021Fire-Resistant Penetrations and Jointsstephan thimmespecial
10/29/2021Energy Code Compliance Inspectionsstephan thimmeprogress
02/16/2021Fire-Resistant Penetrations and Jointsstephan thimmespecial
02/12/2021Lighting in dwelling unitsstephan thimmeenergy_progress
02/12/2021Energy Code Compliancestephan thimmeprogress
02/12/2021Energy Code Compliance Inspectionsstephan thimmeprogress
02/12/2021Fenestration air leakagestephan thimmeenergy_progress
02/12/2021Fenestration areasstephan thimmeenergy_progress
02/12/2021Air barrier - visual inspectionstephan thimmeenergy_progress
02/12/2021Fenestration and door U-factor and product ratingsstephan thimmeenergy_progress
02/12/2021Structural Stability – Alterations of existing buildingsLAWRENCE SHACTELspecial
02/08/2021Finalstephan thimmeprogress
▾Documents — 23 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch - Plumbing3
08/24/2026S00468263-P2Request digital key ↗
08/15/2026S00468263-P1Request digital key ↗
08/14/2026S00468263-I1Request digital key ↗
▸DOB NOWPlans/Sketch - General Construction1
08/15/2026S00466885-I1Request digital key ↗
▸Seals & Professional Certifications17
▸DOB NOWProgress Inspector Seal & Signature8
09/18/2026S00468263-P2Open ↗
09/18/2026S00468263-P2Open ↗
09/01/2026S00468263-P1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/18/2026S00468263-P2Open ↗
09/01/2026S00468263-P1Open ↗
08/28/2026S00466885-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/24/2026S00468263-I1Open ↗
08/24/2026S00468263-P2Open ↗
08/24/2026S00468263-P1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/14/2026S00468263-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026S00466885-I1Open ↗