ECB01/14/2000WOOD STAIR BETWEEN CELLAR AND FIRST FLOOR IS NOT PERMITTED AS PER SECTION 27-375 (B), AND CLOSET UNDER THE STAIR IS NOT PERMITTED. REMOVE CLOSET AND MAKE STAIR OF NON COMBUSTIBLE MATERIALS AS REQUIREDNothing owed — awaiting certificate of correction
ECB01/14/2000ROOF ACCESS IS MISSING IN THAT A SCUTTLE HAS NOT BEEN PROVIDED AS PER SECTION 27-375(K)(3) REMEDY: PROVIDE REQUIRED SCUTTLE IN COMPLIANCE WITH REFERENCE SECTION OF THE BUILDING CODE.Nothing owed — awaiting certificate of correction
ECB01/14/2000SKYLIGHT AND VENTILATORS FOR STAIR ENCLOSURE ARE NOT PROVIDED AS PER SECTION 27-375 (I) (4) (A) REMEDY: PROVIDE REQUIRED SKYLIGHT AND VENTILATOR IN COMPLIANCE WITH REFRENCED SECTION OF THE BUILDING CODENothing owed — awaiting certificate of correction
ECB01/14/2000HANDICAPP ACCESS IS NOT PROVIDED AS PER SECTION 27-295.5(A) REMEDY: MAKE ALL PRIMARY ENTRANCES FOR THE BUILDING ACCESSIBLENothing owed — awaiting certificate of correction
ECB01/14/2000FIRE STOPPING AT PARTY WALLS IS NOT PROVIDED CONTRARY TO SECTION 27-332 REMEDY; PROVIDE FIRE STOPPING AS REQUIRED BY REFRENCED SECTION OF THE BUILDING CODE ,Nothing owed — awaiting certificate of correction
ECB01/14/2000STRUCTURAL DEFECTS WERE OBSERVED IN VIOLATION OF REFRENCE STANDARD RS10-5B IN THAT : 1- NO STRAP BRACING FOR "C" JOISTS WAS PRESENT ,2- NO ANCHORAGE BETWEEN JOIST AND BEARING OR NON- BEARING WALLS WAS PROVIDEDNothing owed — awaiting certificate of correction
ECB01/14/2000FLOOR AREA OF THE BUILDING EXCEED FLOOR AREA PERMITTED BY ZONING RESOLUTION SECTION ZR 23-145. REMEDY: MAKE BUILDING COMPLY WITH ZONING RESOLUTION OR OBTAIN VARIANCENothing owed — awaiting certificate of correction
ECB01/14/2000BUILDING DOES NOT COMPLY WITH THE MQUALITY HOUSING PROGRAM SECTION ZR- 28-12 AND ZR 28-22 IN THAT STREET TREE PLANTING AND DOUBLE -GLAZED WINDOWS HAVE NOT BEEN PROVIDED , AS REQUIRED . REMEDY: PROVIDE TREES ANDNothing owed — awaiting certificate of correction
ECB01/13/2000WOOD STAIR BETWEEN CELLAR AND FIRST FLOOR IS NOT PERMITTED AS PER SECTION 27-375 (H) ,AND CLOSET UINDER THE STAIR IS NOT PERMITTED . REMEDY: REMOVE CLOSET AND MAKE STAIR OF NON-COMBUSTIBLE MATERIAL AS REQUIREDNothing owed — awaiting certificate of correction
ECB01/13/2000BUILDING DOES NOT COMPLY WITH THE QUALITY HOUSING PROGRAM SECTIONS ZR 28-12 AND ZR 28-22 IN THAT STREET TREE PLANTING AND DOUBLE GLAZED WINDOWS HAVE NOT BEEN PROVIDED AS REQUIRED. PROVIDE TREES AND WINDOWS IN CNothing owed — awaiting certificate of correction
ECB01/13/2000FLOOR AREA OF THE BUILDING EXCEEDS FLOOR AREA PERMITTED BY ZONING RESOLUTION SECTION ZR 23-145. MAKE BUILDING COMPLY WITH ZONING RESOLUTION OR OBTAIN VARIANCE.Nothing owed — awaiting certificate of correction
ECB01/13/2000STRUCTURAL DEFECTS WERE OBSERVED IN VIOLATION OF REFERENCE STANDARDS RS10-5B IN THAT NO STRAP BRACING FOR "C" JOINTS WAS PRESENT. NO ANCHORAGE BETWEEN JOIST AND BEARING OR NON BEARING WALLS WAS PROVIDED. STIFFNothing owed — awaiting certificate of correction
ECB01/13/2000ROOF ACCESS IS MISSING IN THAT A SCUTTLE HAS NOT BEEN PROVIDED AS PER SECTION 27-375(K)(3) REMEDY; PROVIDE REQUIRED SCHUTTLE IN COMPLIANCE WITH REFRENCED SECTION OF THE BUILDING CODENothing owed — awaiting certificate of correction
ECB01/13/2000SKYLIGHT AND VENTILATORS FOR STAIR ENCLOSURE ARE NOT PROVIDED AS PER SECTION 27-375 (I) (4) (A) REMEDY: PROVIDE REQUIRED SKYLIGHT AND VENTILATOR IN COMPLIANCE WITH REFRENCED SECTION OF THE BUILDING CODE.Nothing owed — awaiting certificate of correction
ECB01/13/2000HANDICAP ACCESS IS NOT PROVIDED AS PER SECTION 27-292.5 (A) REMEDY: MAKE ALL PRIMARY ENTRABCES FOR THE BUILDING ACCESSIBLENothing owed — awaiting certificate of correction
ECB01/13/2000FIRE STOPPING AT PARTY WALLS IS NOT PROVIDED ,CONTRARY TO SECTION 27-332. REMEDY: PROVIDE FIRE STOPPING AS REQUIRED BY REFRENCE SECTION OF CODENothing owed — awaiting certificate of correction