1 Active Violation ▸FDNY Report ↗
City residence, one family · Owner of record: May Kyi NG Trust Dated September 5 · 2,000 sf lot · 1.21 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof15p · 2 filings · 20 docs
Floor 325p · 2 filings · 20 docs
Floor 226p · 2 filings · 20 docs
Floor 127p · 2 filings · 20 docs
Cellar27p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Eagle Street Development1007/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/27/2021$2.0M—Private party → Private party$829/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Prime Zone Building Consulting511/03/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Prime Zone Building Consulting503/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NTF ManagementGeneral Contractor207/08/2026
P.S.I. MechanicalPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Jian Engineering7397211/03/2025
Lam and Co Consulting8065211/03/2025
NKM Engineering6244211/03/2025
M. International Engineering3129101/22/2025
Prime Zone Building Consulting9474103/26/2024
Building Lifecycle
07/02/2026
Closed: Landmark (DOB violation)
DOB violation · closed on the city's record
04/22/2026
Signed off — Alteration
INTERIOR RENOVATION IN EXISTING 1-FAMILY 3-STY. RESIDENTIAL BUILDING WITH CELLAR. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THIS APPLICATION.
B01021673-I1
04/21/2026
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
03/12/2026
Closed: Borough commissioner has ordered all work stopped under permit #B01021673-I1 on 10/22/25. Intent to revoke approval and permit. Contact borough…
DOB violation · closed on the city's record
03/04/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
46 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offNTF Management03/05/2025
DOB NOWPlumbingSigned-offP.S.I. Mechanical01/09/2025
DOB NOWPlumbingSigned-offP.S.I. Mechanical07/29/2024
DOB NOWGeneral ConstructionSigned-offNTF Management07/26/2024
2 projects · most recent 09/09/2025
General Wiring
FiledStatusContractorScope
09/09/2025CompleteKJK ElectricGeneral Wiring
08/22/2024CompleteKJK Electric—
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
04/21/2026Pass-Final General Construction Non-Directive 14PassView ↗
03/04/2026Fail-Final General Construction Non-Directive 14FailView ↗
08/01/2025Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
08/01/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/24/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
01/24/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/24/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 23
DateRequirementInspectorRole
12/19/2025Concrete - Cast-In-PlaceJIAN DENGspecial
12/19/2025Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
12/19/2025Fire-Resistant Penetrations and JointsCHI WAI CHUNGspecial
12/19/2025Energy Code Compliance InspectionsCHI WAI CHUNGprogress
12/19/2025Interior lighting powerCHI WAI CHUNGenergy_progress
11/03/2025Fire-Resistant Penetrations and JointsCHI WAI CHUNGspecial
11/03/2025Concrete - Cast-In-PlaceJIAN DENGspecial
11/03/2025Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
11/03/2025Energy Code Compliance InspectionsCHI WAI CHUNGprogress
11/03/2025Interior lighting powerCHI WAI CHUNGenergy_progress
01/16/2025Interior lighting powerCHI WAI CHUNGenergy_progress
01/16/2025Concrete - Cast-In-Place—special
01/16/2025HVAC-R and service water piping design and insulationCHI WAI CHUNGenergy_progress
01/16/2025Fire-Resistant Penetrations and JointsCHI WAI CHUNGspecial
01/16/2025Structural Stability – Alterations of existing buildingsNANIK MASSANDspecial
01/16/2025Energy Code Compliance InspectionsCHI WAI CHUNGprogress
01/16/2025Energy Code Compliance InspectionsCHI WAI CHUNGprogress
01/16/2025HVAC-R and service water heating equipmentCHI WAI CHUNGenergy_progress
01/16/2025HVAC-R and service water heating system controlsCHI WAI CHUNGenergy_progress
01/03/2025HVAC-R and service water piping design and insulationCHI WAI CHUNGenergy_progress
01/03/2025HVAC-R and service water heating system controlsCHI WAI CHUNGenergy_progress
01/03/2025HVAC-R and service water heating equipmentCHI WAI CHUNGenergy_progress
01/03/2025Energy Code Compliance InspectionsCHI WAI CHUNGprogress
40 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account