← Back
Elevator apt, fireproof with stores
39 WAVERLY AVENUE
BROOKLYN · BIN 3054140
💬 Discuss this project
1920Year Built
7Stories
D6Building Class
M1-2Zoning
184,411 sfGross Floor Area
80Units
LL97 CoveredRent Stabilized28 Open Violations 22 unresolved · 6 paperwork only ▸FDNY Report ↗
Elevator apt, fireproof with stores · Owner of record: THOR CHOCOLATE FACTORY LLC · 41,196 sf lot · 4.48 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Permit Issued — active, not yet Signed-off
Roof23p · 2 filings · 20 docs
Floor 7115p · 7 filings · 20 docs
Floor 6109p · 7 filings · 20 docs
Floor 5111p · 7 filings · 20 docs
Floor 4124p · 8 filings · 20 docs
Floor 3120p · 7 filings · 20 docs
Floor 2119p · 7 filings · 20 docs
Floor 1Under Construction50p · 7 filings · 20 docs
CellarUnder Construction35p · 6 filings · 20 docs
3 jobs · most recent 03/28/2025
Ventilation Systems Associated Ducts and Piping Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
03/28/2025——Ventilation Systems
Ventilation
Captiveaire SIF9DD 50 CFM · Makeup Air ×1
05/02/2022Permit IssuedSUPERIOR HVAC INCAssociated Ducts and Piping, Heating and Air Conditioning Systems
Heat / Cool
Daikin RXYQ120XATJA 120,000 BTU · Vrf Outdoor ×2
RXYQ192XATJA 192,000 BTU · Vrf Outdoor ×2
Ducts & Piping
Daikin FXSQ54TAVJU 54,000 BTU · Vrf Indoor ×8
FXAQ07PVJU 7,500 BTU · Vrf Indoor ×2
FXFQ24TVJU 23,000 BTU · Vrf Indoor ×2
FXTQ24TAVJUA 24,000 BTU · Vrf Indoor ×2
10/23/2020——Ventilation Systems—
1 job · most recent 06/02/2022
FiledStatusContractorScope
06/02/2022Permit IssuedLLOYD G DRUMMOND PLBG&GEN—
8 jobs · most recent 04/29/2026
Gas Water/Sanitary
FiledStatusContractorScope
04/29/2026Permit IssuedNEPTUNE MECHANICAL INCGas
06/02/2022Permit IssuedLLOYD G DRUMMOND PLBG&GENGas, Water/Sanitary
09/22/2021Signed-offI & I PLUMBING CORPGas, Water/Sanitary
03/25/2021Permit IssuedI & I PLUMBING CORPGas, Water/Sanitary
03/25/2021Permit IssuedI & I PLUMBING CORPGas, Water/Sanitary
03/25/2021Permit IssuedI & I PLUMBING CORPGas, Water/Sanitary
02/18/2021Permit IssuedI & I PLUMBING CORPGas, Water/Sanitary
10/29/2020Permit IssuedI & I PLUMBING CORPWater/Sanitary
25 jobs · most recent 11/24/2025
General Wiring
FiledStatusContractorScope
11/24/2025Permit IssuedROBERT CHIMENTIGeneral Wiring
06/13/2025CompleteROBERT CHIMENTIGeneral Wiring
06/13/2025CompleteROBERT CHIMENTIGeneral Wiring
06/13/2025CompleteROBERT CHIMENTIGeneral Wiring
06/13/2025CompleteROBERT CHIMENTIGeneral Wiring
06/13/2025CompleteROBERT CHIMENTIGeneral Wiring
06/13/2025CompleteROBERT CHIMENTIGeneral Wiring
06/12/2025CompleteROBERT CHIMENTIGeneral Wiring
12/19/2024Permit IssuedMAXIMUM ELECTRIC CORP.General Wiring
12/13/2024Permit IssuedMAXIMUM ELECTRIC CORP.General Wiring
05/10/2022CompleteWORD OF LIGHT ELECT LLCGeneral Wiring
02/10/2022Permit IssuedTRINCITY ELECTRIC, INCGeneral Wiring
11/11/2021CompleteWORD OF LIGHT ELECT LLCGeneral Wiring
09/20/2021Permit IssuedWORD OF LIGHT ELECT LLCGeneral Wiring
07/26/2021CompleteECNY ELEC'L CONTR'S, INC—
2 jobs · most recent 02/06/2025
Steel
FiledStatusContractorScope
02/06/2025Permit IssuedSKYLINE BUILDERS GROUP LL1 scope_items
09/10/2021——Steel
1 job · most recent 04/29/2026
Tenant Protection Plan 72 Hour
FiledStatusContractorScope
04/29/2026Permit IssuedNEPTUNE MECHANICAL INCTenant Protection Plan 72 Hour
Building Lifecycle
All (300)Filed (55)Permit Issued (52)Signed Off (6)Violation (60)Inspection (41)Objection (56)Special Inspection (30)
09/09/2026
Permit issued — Structural
B01210303-I1-ST
07/28/2026
Permit issued — Structural
B01210303-I1-ST
06/03/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/22/2026
Violation issued (HPD, open)
C
05/11/2026
Objection resolved — Addressed
05/04/2026
Objection raised — Scope
05/04/2026
Objection raised — Cost
05/04/2026
Objection raised — Scope
04/29/2026
Filed — Alteration
INSTALL NEW GAS METER AND PIPING TO NEW BOILER AND KITCHEN APPLIANCES.
B01258836-P1
04/27/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
04/02/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/23/2026
Violation issued (ECB, closed)
Unknown
03/16/2026
Violation issued (HPD, open)
A
03/16/2026
Violation issued (HPD, open)
B
03/11/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
03/05/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/04/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
02/26/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/24/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/13/2026
Permit issued — Plumbing
B00756881-S1-PL
02/04/2026
Filed — Alteration
PROPOSED INTERIOR RENOVATION TO APARTMENTS 2B, 2D, 3E, 3O, 3Q, 5D, 5L, 5M, 7Q. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B00756881-S1
02/04/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Brian McDonough
02/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Brian McDonough
02/04/2026
Special inspection requirement — Energy Code Compliance Inspections
Brian McDonough
01/30/2026
Violation issued (HPD, closed)
A
01/26/2026
Permit issued — Boiler Equipment
B01258836-I1-BE
01/26/2026
Permit issued — Plumbing
B01258836-S1-PL
12/19/2025
Permit issued — Structural
B01172063-I1-ST
12/10/2025
Objection resolved — Addressed
11/19/2025
Objection resolved — Addressed
11/18/2025
Filed — Alteration
PROPOSED INTERIOR RENOVATION TO APARTMENTS 2B, 2D, 3E, 3O, 3Q, 5D, 5L, 5M, 7Q. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B00756881-P4
11/18/2025
Objection resolved — Addressed
11/07/2025
Objection resolved — Addressed
11/07/2025
Objection resolved — Addressed
11/07/2025
Objection resolved — Addressed
11/06/2025
Objection raised — Plumbing
11/06/2025
Objection raised — Other
11/06/2025
Objection raised — Plumbing
11/06/2025
Objection raised — Plumbing
11/06/2025
Objection raised — Plumbing
11/05/2025
Special inspection requirement — Final
Jerry Caldari
11/03/2025
Violation issued (HPD, closed)
C
10/29/2025
Objection resolved — Addressed
10/29/2025
Objection resolved — Addressed
10/29/2025
Objection resolved — Addressed
10/28/2025
Objection raised — Plumbing
10/28/2025
Objection raised — Plumbing
10/24/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
10/21/2025
Objection resolved — Addressed
10/07/2025
Violation issued (FDNY_NOV, closed)
10/07/2025
Violation issued (FDNY_NOV, closed)
09/29/2025
Objection raised — Scope
09/26/2025
Objection raised — Plumbing
09/26/2025
Objection raised — Mechanical
09/16/2025
Filed — Alteration
INSTALL NEW GAS METER AND PIPING TO NEW BOILER AND KITCHEN APPLIANCES.
B01258836-S1
09/16/2025
Filed — Alteration
INSTALL NEW GAS METER AND PIPING TO NEW BOILER AND KITCHEN APPLIANCES.
B01258836-I1
09/02/2025
Filed — Alteration
PROPOSED INTERIOR RENOVATION TO APARTMENTS 2B, 2D, 3E, 3O, 3Q, 5D, 5L, 5M, 7Q. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B00756881-P3
08/01/2025
Violation issued (HPD, closed)
A
07/28/2025
Permit issued — Structural
B01210303-I1-ST
07/21/2025
Special inspection requirement — Heating Systems
LOUIS ARENA
Latest 60 of 300 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
THOR EQUITIES2309/10/2026
GFB MANAGEMENT6607/08/2026
BROOKLYN CREATIVE LEAGUE1107/08/2026
275 PARK PERFORMANCE VENUE1907/08/2026
KINGS GROUP NY2707/08/2026
275 PARK OWNER4007/08/2026
FSC D&C LLC703/22/2026
THOR CHOCOLATE FACTORY LLC703/22/2026
PROGENY CONSTRUCTION303/22/2026
275 PARK AVENUE LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/08/2024$58.5M—275 PARK OWNER LLC → THOR CHOCOLATE FACTORY LLC$317/sf building
08/12/2014$68.0M—— → —$369/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KNA CONSULTING9603/21/2026
ARSENAL BUILDING CONSULTANTS LLC403/21/2026
NEW YORK ENGINEERING ASSOCIATES P C403/21/2026
LEVIN ENGINEERING PLLC203/21/2026
METROPOLIS GROUP INC203/21/2026
EA DESIGN GROUP803/21/2026
AE DESIGN SOLUTION203/21/2026
WRG ENGINEERING P C403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KINGS GROUP NY CORPGeneral Contractor2207/08/2026
GLENNS PLUMBING SVCS INCPlumbing2007/08/2026
PROGENY CONSTRUCTION CORPGeneral Contractor1707/08/2026
BEK PLBG & HTG LLCPlumbing1107/08/2026
BLACK HAMMER CONSTRUCTIONGeneral Contractor507/08/2026
CYPRESS GREEN CONST COGeneral Contractor407/08/2026
EBRO DIQUE GROUP, LLCGeneral Contractor407/08/2026
SKYLINE BUILDERS GROUP LLGeneral Contractor409/10/2026
PRO BUILDERS R CONSTRUCTIGeneral Contractor303/21/2026
NEPTUNE MECHANICAL INCPlumbing207/08/2026
SUPERIOR HVAC INCGeneral Contractor203/21/2026
AP PLUMBING & HVAC LLCPlumbing107/08/2026
LLOYD G DRUMMOND PLBG&GENPlumbing107/08/2026
FRANKLYLOFTY CONSTRUCTIONGeneral Contractor107/08/2026
FIBERTEK DATA & ELEC CORPElectrical103/22/2026
GONZALEZ, RAFAELElectrical103/21/2026
ROBERT CHIMENTIElectrical103/21/2026
ROBERT CHIMENTIElectrical103/22/2026
WORD OF LIGHT ELECT LLCElectrical103/22/2026
CROSSFIELD PLBG.&HTG.CORPFire Protection107/08/2026
LLOYD G DRUMMOND PLBG&GENFire Protection107/08/2026
AIR DEPOT COMM. REFR. CORGeneral Contractor107/08/2026
CHIMENTI, ROBERTElectrical103/21/2026
LUMA CONSTRUCTION LLCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NEW YORK ENGINEERING ASSO851304/29/2026
MCDONOUGH ENGINEERING PRA9377102/04/2026
WRG ENGINEERING, P.C.4403206/23/2025
BROMLEY CALDARI ARCHITECT1534103/28/2025
SURFACE DESIGN PROFESSION3968205/24/2024
BFS ARCHITECT PC74771401/26/2023
COLE TECHNOLOGIES/CONTROL1290707/28/2022
CES ENGINEERING LLC1277809/14/2021
GASBARRO STRUCTURAL ENGIN5919109/10/2021
ERIC SAFYAN ARCHITECTPC3248104/13/2021
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedSKYLINE BUILDERS GROUP LL09/09/2026
DOB NOWStructuralPermit IssuedSKYLINE BUILDERS GROUP LL07/28/2026
DOB NOWPlumbingSigned-offBEK PLBG & HTG LLC02/13/2026
DOB NOWBoiler EquipmentPermit IssuedNEPTUNE MECHANICAL INC01/26/2026
DOB NOWPlumbingPermit IssuedNEPTUNE MECHANICAL INC01/26/2026
DOB NOWStructuralPermit IssuedSKYLINE BUILDERS GROUP LL12/19/2025
DOB NOWStructuralPermit IssuedSKYLINE BUILDERS GROUP LL07/28/2025
DOB NOWGeneral ConstructionPermit IssuedLUMA CONSTRUCTION LLC05/08/2025
DOB NOWSidewalk ShedSigned-offKINGS GROUP NY CORP05/02/2024
DOB NOWSupported ScaffoldSigned-offKINGS GROUP NY CORP01/19/2024
DOB NOWSidewalk ShedSigned-offKINGS GROUP NY CORP05/04/2023
DOB NOWProtection and Mechanical MethodsPermit IssuedEBRO DIQUE GROUP, LLC03/23/2023
DOB NOWGeneral ConstructionSigned-offEBRO DIQUE GROUP, LLC03/17/2023
DOB NOWSupported ScaffoldSigned-offKINGS GROUP NY CORP02/09/2023
DOB NOWGeneral ConstructionPermit IssuedBLACK HAMMER CONSTRUCTION11/16/2022
DOB NOWSidewalk ShedSigned-offKINGS GROUP NY CORP08/23/2022
DOB NOWGeneral ConstructionPermit IssuedPROGENY CONSTRUCTION CORP08/17/2022
DOB NOWSprinklersPermit IssuedLLOYD G. DRUMMOND07/27/2022
DOB NOWSprinklersPermit IssuedLLOYD G DRUMMOND PLBG&GEN07/11/2022
DOB NOWMechanical SystemsPermit IssuedSUPERIOR HVAC INC06/27/2022
DOB NOWGeneral ConstructionPermit IssuedPRO BUILDERS R CONSTRUCTI06/10/2022
DOB NOWSidewalk ShedSigned-offKINGS GROUP NY CORP05/17/2022
DOB NOWGeneral ConstructionPermit IssuedBLACK HAMMER CONSTRUCTION03/11/2022
DOB NOWGeneral ConstructionPermit IssuedBLACK HAMMER CONSTRUCTION03/10/2022
DOB NOWGeneral ConstructionPermit IssuedCYPRESS GREEN CONST CO02/28/2022
DOB NOWMechanical SystemsSigned-offAIR DEPOT COMM REFR COR12/09/2021
DOB NOWPlumbingPermit IssuedGLENNS PLUMBING SVCS INC11/13/2021
DOB NOWStructuralPermit IssuedFRANKLYLOFTY CONSTRUCTION11/05/2021
DOB NOWGeneral ConstructionSigned-offPROGENY CONSTRUCTION CORP11/03/2021
DOB NOWGeneral ConstructionPermit IssuedPROGENY CONSTRUCTION CORP10/07/2021
DOB NOWPlumbingSigned-offGLENNS PLUMBING SVCS INC09/30/2021
DOB NOWPlumbingSigned-offCROSSFIELD PLBG.&HTG09/29/2021
DOB NOWSprinklersSigned-offCROSSFIELD PLBG.&HTG.CORP09/29/2021
DOB NOWGeneral ConstructionPermit IssuedPROGENY CONSTRUCTION CORP09/15/2021
DOB NOWSidewalk ShedSigned-offKINGS GROUP NY CORP08/25/2021
DOB NOWPlumbingPermit IssuedGLENNS PLUMBING SVCS INC08/03/2021
DOB NOWGeneral ConstructionPermit IssuedPROGENY CONSTRUCTION CORP07/23/2021
DOB NOWGeneral ConstructionPermit IssuedCYPRESS GREEN CONST CO07/19/2021
DOB NOWPlumbingPermit IssuedGLENNS PLUMBING SVCS INC07/13/2021
DOB NOWPlumbingPermit IssuedGLENNS PLUMBING SVCS INC07/01/2021
+ 60 more permits on file
▾Field Inspections (DOB CAP) — 41
DateTypeResultReport
06/03/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/27/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
04/02/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/11/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
03/05/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/04/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
02/26/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/24/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/24/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
12/20/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
12/20/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
12/20/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/18/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
12/11/2024Pass-Final CND-Occupancy InspectionPassView ↗
08/08/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/23/2023Pass-Final CND-Occupancy InspectionPassView ↗
11/17/2022Pass-Final CND-Occupancy InspectionPassView ↗
11/16/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/08/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/06/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
08/29/2022Pass-Final CND-Occupancy InspectionPassView ↗
08/16/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/15/2022Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
08/09/2022Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
07/15/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
Latest 25 of 41.
▾Special Inspection Requirements (DOB NOW) — 117
DateRequirementInspectorRole
02/04/2026Energy Code Compliance InspectionsBrian McDonoughprogress
02/04/2026Fire-Resistant Penetrations and JointsBrian McDonoughspecial
02/04/2026HVAC-R and service water piping design and insulationBrian McDonoughenergy_progress
11/05/2025FinalJerry Caldariprogress
07/21/2025Energy Code Compliance InspectionsLOUIS ARENAprogress
07/21/2025Heating SystemsLOUIS ARENAspecial
07/21/2025Tenant Protection Plan ComplianceLOUIS ARENAspecial
07/21/2025Maintenance informationLOUIS ARENAenergy_progress
07/21/2025HVAC-R and service water heating system controlsLOUIS ARENAenergy_progress
07/21/2025HVAC-R and service water piping design and insulationLOUIS ARENAenergy_progress
07/21/2025HVAC-R and service water heating equipmentLOUIS ARENAenergy_progress
07/21/2025Tenant Protection Plan ComplianceLOUIS ARENAspecial
04/14/2025MasonryWinston Garciaspecial
04/14/2025FinalWinston Garciaprogress
04/14/2025Sprayed fire-resistant materialsWinston Garciaspecial
04/14/2025Structural Cold-Formed SteelWinston Garciaspecial
04/14/2025Tenant Protection Plan ComplianceWinston Garciaspecial
04/14/2025Structural Steel - WeldingWinston Garciaspecial
04/14/2025Structural Steel - High Strength BoltingWinston Garciaspecial
04/14/2025Post-installed AnchorsWinston Garciaspecial
04/14/2025Fire-Resistant Penetrations and JointsWinston Garciaspecial
04/14/2025Structural Steel - DetailsWinston Garciaspecial
03/19/2025Tenant Protection Plan ComplianceAshley Rauenzahnspecial
03/13/2025HVAC-R and service water piping design and insulation—energy_progress
03/13/2025Fire-Resistant Penetrations and Joints—special
Latest 25 of 117.
▾Documents — 900 on file (BIS + DOB NOW)
▸Plans & Drawings68
▸DOB NOWPlans/Sketch43
09/01/2026B00498827-P1Contact architect ↗
09/01/2026B00543800-I1Contact architect ↗
09/01/2026B00590186-I1Contact architect ↗
Showing 3 of 43 on file for this type
▸DOB NOWPlans/Sketch - Plumbing16
09/02/2026B00421341-I1Contact architect ↗
09/01/2026B00453799-I1Contact architect ↗
09/01/2026B00418021-I1Contact architect ↗
Showing 3 of 16 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems6
09/02/2026B00417323-I1Contact architect ↗
09/02/2026B00417884-I1Contact architect ↗
09/02/2026B00417976-I1Contact architect ↗
Showing 3 of 6 on file for this type
▸DOB NOWPlans/Sketch - Place of Assembly1
08/28/2026B00780644-I1Contact architect ↗
▸DOB NOWPlans/Sketch - Sidewalk Shed1
09/02/2026B00384160-I1Contact architect ↗
▸DOB NOWPlans/Sketch - General Construction1
09/01/2026B00448936-I1Contact architect ↗
▸Applications & Permits127
▸BISPLAN / WORK APPROVAL APPLICATION69
08/06/2025322068098Open ↗
06/06/2024340765014Open ↗
01/24/2022321479985Open ↗
Showing 3 of 69 on file for this type
▸BISWORK PERMIT APPLICATION50
11/19/2020340780177Open ↗
11/17/2020340779438Open ↗
11/17/2020340779401Open ↗
Showing 3 of 50 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION6
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 6 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Seals & Professional Certifications268
▸DOB NOWDPL-1: Design Professional Seal & Signature68
09/02/2026B00417323-I1Open ↗
09/02/2026B00417884-I1Open ↗
09/02/2026B00417976-I1Open ↗
Showing 3 of 68 on file for this type
▸DOB NOWProgress Inspector Seal & Signature50
09/23/2026B00493268-P2Open ↗
09/23/2026B00493268-P2Open ↗
09/01/2026B01210303-I1Open ↗
Showing 3 of 50 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature46
09/23/2026B00493268-P2Open ↗
09/01/2026B01210303-I1Open ↗
09/01/2026B01210303-I1Open ↗
Showing 3 of 46 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION33
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 33 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT24
01/19/2021340799568Open ↗
10/28/2020340780177Open ↗
10/23/2020340779321Open ↗
Showing 3 of 24 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION20
01/19/2021340799568Open ↗
10/28/2020340780177Open ↗
10/23/2020340779321Open ↗
Showing 3 of 20 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY11
10/28/2020340780177Open ↗
10/01/2020340765014Open ↗
08/14/2020340755310Open ↗
Showing 3 of 11 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST10
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 10 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
10/01/2020340765014Open ↗
▸Trade Schedules & Equipment28
▸BISSCHEDULE B - PLUMBING19
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 19 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE7
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 7 on file for this type
▸BISFA - FDNY APPROVAL : FD-FAA1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISSELF-CERT PLUMBING NOTICE1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Safety & Tenant Protection54
▸BISTENANT PROTECTION PLAN AND NOTES27
04/27/2021340726593Open ↗
04/27/2021322020852Open ↗
03/09/2021322085550Open ↗
Showing 3 of 27 on file for this type
▸DOB NOWTenant Protection Plan22
09/02/2026B00417323-I1Open ↗
09/02/2026B00417884-I1Open ↗
09/02/2026B00417976-I1Open ↗
Showing 3 of 22 on file for this type
▸BISSTREET TREE CHECKLIST5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸Environmental & Asbestos85
▸DOB NOWDEP ACP-5: Asbestos Assessment Report59
09/02/2026B00417323-I1Open ↗
09/02/2026B00417884-I1Open ↗
09/02/2026B00417976-I1Open ↗
Showing 3 of 59 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)15
10/28/2020340780177Open ↗
10/01/2020340765014Open ↗
08/14/2020340755310Open ↗
Showing 3 of 15 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'7
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 7 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/27/2026B00817800-I1Open ↗
▸Energy Compliance45
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY18
11/19/2020340780177Open ↗
10/28/2020340780177Open ↗
10/27/2020340765014Open ↗
Showing 3 of 18 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS10
10/28/2020340780177Open ↗
10/01/2020340765014Open ↗
08/14/2020340755310Open ↗
Showing 3 of 10 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS10
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 10 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸DOB NOWEN2: As Built Energy Analysis2
09/01/2026B00606006-I1Open ↗
Showing 1 of 2 on file for this type
▸BISAIR SEALING AND INSULATION - VISUAL1
06/24/2024340765014Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
06/24/2024340765014Open ↗
▸Inspections & Test Reports43
▸BISTECHNICAL REPORT: RESPONSIBILITY32
03/29/2021340726593Open ↗
03/29/2021340726593Open ↗
03/11/2021340726593Open ↗
Showing 3 of 32 on file for this type
▸BISDIR-14 ID OF RESPONSIBILITY (TR1)9
11/17/2020340779438Open ↗
11/17/2020340779401Open ↗
11/17/2020340779394Open ↗
Showing 3 of 9 on file for this type
▸BISSUBSURFACE / SOILS INVESTIGATION (BORINGS/TEST PITS)1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISMASONRY1
06/24/2024340765014Open ↗
▸Approvals, Objections & Sign-offs48
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST20
06/25/2024340765014Open ↗
Showing 1 of 20 on file for this type
▸BISFINAL10
06/24/2024340765014Open ↗
11/17/2020340779438Open ↗
11/17/2020340779401Open ↗
Showing 3 of 10 on file for this type
▸BISADMINISTRATIVE OBJECTIONS9
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 9 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISSUPERSEDING LETTER2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Cost, Insurance & Ownership57
▸BISCOST AFFIDAVIT56
01/19/2021340799568Open ↗
10/28/2020340780177Open ↗
10/23/2020340779321Open ↗
Showing 3 of 56 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW31
06/24/2024340765014Open ↗
▸Filing & Intake Forms74
▸BISADDITIONAL INFORMATION23
06/21/2024340765014Open ↗
02/01/2022320009959Open ↗
03/31/2021340726593Open ↗
Showing 3 of 23 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET21
01/19/2021340799568Open ↗
10/28/2020340780177Open ↗
10/23/2020340779321Open ↗
Showing 3 of 21 on file for this type
▸BISEFILING COVER SHEET16
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 16 on file for this type
▸BISBOROUGH INTAKE FORM14
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 14 on file for this type
▸Other Documents3
▸BISDHCR DOCUMENT1
02/15/2022320009959Open ↗
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISFIRE SUPP ANSUL APPROVL- FD-FSS1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type